PubMed Health⌕ Search

Biomedical subjects

T Teutenberg

Publications and source records attributed to T Teutenberg.

3 recordsLinked to original sources

Development and application of a specially designed heating system for temperature-programmed high-performance liquid chromatography using subcritical water as the mobile phase.

A specially designed heating system for temperature-programmed HPLC was developed based on experimental measurements of eluent temperature inside a stainless steel capillary using a very thin thermocouple. The heating system can be operated at temperatures up to 225 degrees C and consists of a preheating, a column heating and a cooling unit. Fast cycle times after a temperature gradient can be realized by an internal silicone oil bath which cools down the preheating and column heating unit. Long-term thermal stability of a polybutadiene-coated zirconium dioxide column has been evaluated using a tubular oven in which the column was placed. The packing material was stable after 50h of operation at 185 degrees C. A mixture containing four steroids was separated at ambient conditions using a mobile phase of 25% acetonitrile:75% deionized water and a mobile phase of pure deionized water at 185 degrees C using the specially designed heating system and the PBD column. Analysis time could be drastically reduced from 17 min at ambient conditions and a flow rate of 1 mL/min to only 1.2 min at 185 degrees C and a flow rate of 5 mL/min. At these extreme conditions, no thermal mismatch was observed and peaks were not distorted, thus underlining the performance of the developed heating system. Temperature programming was performed by separating cytostatic and antibiotic drugs with a temperature gradient using only water as the mobile phase. In contrast to an isocratic elution of this mixture at room temperature, overall analysis time could be reduced two-fold from 20 to 10 min.

Chromatography, High Pressure Liquid↗

Evaluation of column bleed by using an ultraviolet and a charged aerosol detector coupled to a high-temperature liquid chromatographic system.

In this study, five different HPLC columns were heated to 200 degrees C using a homemade heating system which can be operated in temperature programmed mode. The column bleed as an indicator of induced degradation of the stationary phase material was evaluated using a charged aerosol detector (CAD) and an ultraviolet diode array detector (UV-DAD) at different wavelengths. The silica based C-18 stationary phase gave the highest bleed, and the carbon clad titanium dioxide column the lowest bleed. This was independent of both the detection technique and the wavelength.

Aerosols↗

Separation of selected anticancer drugs using superheated water as the mobile phase.

Six anticancer drugs have been eluted on a polystyrene-divinylbenzene (PS-DVB) column with buffered superheated water as the mobile phase. The temperature range studied was from ambient temperature up to 160 degrees C, and the pH of the water was adjusted to 11.5 and 3.5 with phosphate buffer. It was possible to separate the substances 5-fluorouracil (5-FU), methotrexate (MTX), 7-hydroxymethotrexate (7-OH-MTX), and etoposide (VP-16) in one chromatographic run. The separation of these substances was optimized when adjusting the pH from 11.5 to 3.5, resulting in a total elution time of less than 13 min. Furthermore, retention factors of all of the investigated substances were measured at different temperatures and pH values.

Antineoplastic Agents↗