PubMed Health⌕ Search

Biomedical subjects

T Thundat

Publications and source records attributed to T Thundat.

At least 19 recordsLinked to original sources

Nonradiative surface plasmon assisted microscale Marangoni forces.

When a liquid droplet experiences a temperature inhomogeneity along its bounding surface, a surface energy gradient is engendered, which when, in a continuous sense, exceeding a threshold, results in a convective flow dissipating the energy. If the associated temperature gradients are sustained by the interface between the liquid and a supporting substrate, the induced flow can result in the lateral motion of the droplet overcoming the viscosity and inertia. Recently, pico-liter adsorbed and applied droplets were shown experimentally to be transported, and divided by the decay of optically excited surface plasmons into phonons in a thin gold foil. The decaying events locally modify the temperature of the liquid-solid interface, establishing microscale thermal gradients of sufficient magnitude for the droplet to undergo thermocapillary flow. We present experimental evidence of such gradients resulting in local surface modification associated with the excitation of surface plasmons. We show theoretically that the observed effect is due to Marangoni forces, and computationally visualize the flow characteristics for the experimental parameters. As an application based on our results, we propose a method for an all-optical modulation of light by light mediated by the droplet oscillations. Furthermore, the results have important consequences for microfluidics, droplet actuation, and simultaneous surface plasmon resonance sensing and spectroscopy.

Journal Article↗

Microscale Marangoni actuation: all-optical and all-electrical methods.

We present experimental results from an all-optical microfluidic platform that may be complimented by a thin film all-electrical network. Using these configurations we have studied the microfluidic convective flow systems of silicone oil, glycerol, and 1,3,5-trinitrotoluene on open surfaces through the production of surface tension gradients derived from thermal gradients. We show that sufficient localized thermal variation can be created utilizing surface plasmons and/or engaging individually addressable resistive thermal elements. Both studies manipulate fluids via Marangoni forces, each having their unique exploitable advantages. Surface plasmon excitation in metal foils are the driving engine of many physical-, chemical-, and bio-sensing applications. Incorporating, for the first time, the plasmon concept in microfluidics, our results thus demonstrate great potential for simultaneous fluid actuation and sensing.

Glycerol↗

Bioelectromechanical imaging by scanning probe microscopy: Galvani's experiment at the nanoscale.

Since the discovery in the late 18th century of electrically induced mechanical response in muscle tissue, coupling between electrical and mechanical phenomena has been shown to be a near-universal feature of biological systems. Here, we employ scanning probe microscopy (SPM) to measure the sub-Angstrom mechanical response of a biological system induced by an electric bias applied to a conductive SPM tip. Visualization of the spiral shape and orientation of protein fibrils with 5 nm spatial resolution in a human tooth and chitin molecular bundle orientation in a butterfly wing is demonstrated. In particular, the applicability of SPM-based techniques for the determination of molecular orientation is discussed.

Animals↗

Electromechanical imaging of biomaterials by scanning probe microscopy.

The majority of calcified and connective tissues possess complex hierarchical structure spanning the length scales from nanometers to millimeters. Understanding the biological functionality of these materials requires reliable methods for structural imaging on the nanoscale. Here, we demonstrate an approach for electromechanical imaging of the structure of biological samples on the length scales from tens of microns to nanometers using piezoresponse force microscopy (PFM), which utilizes the intrinsic piezoelectricity of biopolymers such as proteins and polysaccharides as the basis for high-resolution imaging. Nanostructural imaging of a variety of protein-based materials, including tooth, antler, and cartilage, is demonstrated. Visualization of protein fibrils with sub-10nm spatial resolution in a human tooth is achieved. Given the near-ubiquitous presence of piezoelectricity in biological systems, PFM is suggested as a versatile tool for micro- and nanostructural imaging in both connective and calcified tissues.

Biocompatible Materials↗

Marangoni forces created by surface plasmon decay.

We present optical microfluidic manipulation of silicone oil and glycerol via surface tension driven forces sustained by surface plasmon deexcitation energy. The phonon energy associated with the decaying optically excited surface plasmons in a thin gold foil creates thermal gradients capable of actuating fluid flows. Spectral dependence of the plasmon decay length and control of optical beam characteristics are shown to provide a means for further manipulation.

Journal Article↗

Photochemical hydrosilylation of 11-undecenyltriethylammonium bromide with hydrogen-terminated Si surfaces for the development of robust microcantilever sensors for Cr(VI).

We report a novel approach to the design and development of microcantilever sensors in which photochemical hydrosilylation is used to modify the microcantilever surface. This process enables individual microcantilevers in multicantilever array chips to be modified separately by focusing the activating UV light sequentially on each particular cantilever. Photochemical hydrosilylation of 11-undecenyltriethylammonium bromide with hydrogen-terminated silicon microcantilever surfaces was carried out to yield a robust quaternary ammonium terminated organic monolayer suitable for chromate detection. The surface functionalities retain their affinity toward Cr(VI), and the organic monolayer is dense enough to generate significant surface stress upon subsequent adsorption of chromate ions from aqueous solutions.

Letter↗

Modulation of multiple photon energies by use of surface plasmons.

A form of optical modulation at low pulse rates is reported in the case of surface plasmons excited by 1.55-microm photons in a thin gold foil. Several visible-photon energies are shown to be pulsed by the action of the infrared pulses, the effect being maximized when each visible beam also excites surface plasmons. The infrared surface plasmons are implicated as the primary cause of thermally induced changes in the foil. The thermal effects dissipate in sufficiently small times so that operation up to the kilohertz range in pulse repetition frequency is obtained. Unlike direct photothermal phenomena, no phase change is necessary for the effect to be observed.

Journal Article↗

Adsorption of trinitrotoluene on uncoated silicon microcantilever surfaces.

We measured the adsorption characteristics of trinitrotoluene (TNT) on piezoresistive silicon microcantilever surfaces under ambient air using a well-characterized TNT vapor generator. This allowed us to quantify the adsorption parameters and to estimate the sticking coefficient. The sticking coefficient initially increases with TNT exposure time and then levels off around 0.3. Atomic force microscopy images of silicon surfaces exposed to TNT revealed "island" formation of the adsorbate on the silicon surface. At low exposure times, mainly the number density of islands increased with exposure time; at longer exposure times, the size (in particular, height) of the islands grew, corresponding to the higher sticking coefficients. These observations can be qualitatively explained via the difference between TNT-surface and TNT-TNT interactions mediated by water molecules.

Adsorption↗

Desorption characteristics of uncoated silicon microcantilever surfaces for explosive and common nonexplosive vapors.

We measured the desorption of explosive trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), and hexahydro-1,3,5-triazine (RDX) vapors from piezoresistive silicon microcantilevers under ambient air. Depending on the amount of vapor loaded on the cantilever, TNT desorption took a few minutes to tens of minutes (for nanogram quantities). On the other hand, no significant loss of PETN or RDX was observed after many hours. We also measured desorption of common "nonexplosive" compounds (water, acetone, and ethyl alcohol) and observed that desorption was too fast to be measured. There is a good correlation between the desorption time and the melting point (or the vapor pressure) of a particular substance. In principle, this method can be used to measure desorption rates of various substances from cantilever surfaces.

Journal Article↗

Probing large area surface plasmon interference in thin metal films using photon scanning tunneling microscopy.

The interference of surface plasmons can provide important information regarding the surface features of the hosting thin metal film. We present an investigation of the interference of optically excited surface plasmons in the Kretschmann configuration in the visible spectrum. Large area surface plasmon interference regions are generated at several wavelengths and imaged with the photon scanning tunneling microscope. Furthermore, we discuss the non-retarded dispersion relations for the surface plasmons in the probe-metal system modeled as confocal hyperboloids of revolution in the spheroidal coordinate systems.

Journal Article↗

Observation of the surface stress induced in microcantilevers by electrochemical redox processes.

The potential-induced surface stress of a solid electrode was investigated in an electrochemical cell. Gold-coated atomic force microscopy microcantilevers were used as working electrodes to measure the current-potential response (by cyclic voltammetry) and simultaneous bending characteristics in solutions of NaNO3 and K3Fe(CN)6/NaNO3. The observed changes of differential surface stress at a microcantilever electrode were attributed to electrochemical-potential-induced changes in surface charge density, ion adsorption/desorption, and electron transfer across the electrode surface. The potential dependent change in stress shows promise for the study of microscopic properties at the solid-electrolyte interface.

Journal Article↗

Thermal transpiration at the microscale: a Crookes cantilever.

Local temperature inhomogeneities in systems containing micron and submicron objects can result in unexpected consequences. If the mean free path of the host gas constituents is comparable to a characteristic length of the system, then a net exchange of momentum occurs between the constituents and the involved surfaces. For a given temperature gradient and a given pressure range, this results in the presence of Knudsen and Knudsen-like forces (KF). The pressure dependence of these forces has been studied using a microelectromechanical system composed of a microcantilever near a substrate surface. Nano-Newton scale KF are observed by the bending of the microcantilever as monitored by the charge variation on the microcantilever-substrate assembly in a capacitive mode.

Journal Article↗

Micromechanical measurement of active sites on silicon nitride using surface free energy variation.

We have investigated chemical reactions between adsorbed water and active sites on a silicon nitride surface as a function of temperature and relative humidity using microcantilevers. Effects that might produce a change in the response of the microcantilever, such as a mass adsorption, surface tension of the adsorbed water, and changes in thermal conductivity, were systematically investigated. It is shown that the judicious choice of experimental conditions could make these effects essentially inconsequential in comparison with the instrument response produced by the change in free surface energy of the microcantilever due to the chemical reactions. Using this method, the variation in free surface energy when changing from dry to high humidity conditions was found and the number of active sites that reacted was estimated. This method may be extended to other problems for use in determining surface free energy change and thus the density of reactant sites under different conditions of interest.

Journal Article↗

An atomic force microscope-based investigation of vertical transport through GaAs/GaAlAs/InAlAs/GaAs step-barrier heterostructures.

Study of vertical transport through heterostructures consisting of single, double, or multiple quantum barriers is of both fundamental and technological interest. While extensive data regarding electron transport is available for single- and double-barrier structures, relatively less information is available for transport through step-barrier structures. In this paper, we present results from a study of room temperature vertical transport through a GaAs/GaAlAs/InAlAs/GaAs multistep-barrier heterostructure. A typical atomic force microscope has been adapted to perform transport measurements, thus allowing precise control of the physical location of the region of measurement. I-V measurements reveal negative differential resistance (NDR) peaks, thus confirming the formation of resonant states in a triangular well created when a voltage bias is applied across the step barrier. I-V curves have also been calculated by numerically solving the Schrödinger wave equation for this step-barrier structure. Comparison between the measured and calculated I-V curves shows reasonable agreement in the number of NDR peaks. However, discrepancies exist between the measured and calculated values for the voltages at which these NDR peaks occur. Some possible reasons for these discrepancies are discussed in this work.

Journal Article↗

Cantilever-based optical deflection assay for discrimination of DNA single-nucleotide mismatches.

Characterization of single-nucleotide polymorphisms is a major focus of current genomics research. We demonstrate the discrimination of DNA mismatches using an elegantly simple microcantilever-based optical deflection assay, without the need for external labeling. Gold-coated silicon AFM cantilevers were functionalized with thiolated 20- or 25-mer probe DNA oligonucleotides and exposed to target oligonucleotides of varying sequence in static and flow conditions. Hybridization of 10-mer complementary target oligonucleotides resulted in net positive deflection, while hybridization with targets containing one or two internal mismatches resulted in net negative deflection. Mismatched targets produced a stable and measurable signal when only a four-base pair stretch was complementary to the probe sequence. This technique is readily adaptable to a high-throughput array format and provides a distinct positive/negative signal for easy interpretation of oligonucleotide hybridization.

Base Pair Mismatch↗

Ultrasensitive detection of CrO4(2-) using a microcantilever sensor.

Microcantilevers modified with a self-assembled monolayer respond sensitively to specific ion concentrations. Here, we report the detection of trace amounts of CrO4(2-) using microcantilevers modified with a self-assembled monolayer of triethyl-12-mercaptododecylammonium bromide. The self-assembled monolayer was prepared on a silicon microcantilever coated with a thin layer of gold on one side. The microcantilever undergoes bending due to sorption of CrO4(2-) ions on the monolayer-modified side. It was found that a concentration of 10(-9) M CrO4(2-) can be detected using this technology in a flow cell. Other anions, such as Cl-, Br-, CO3(2-) (or HCO3-), and SO4(2-), have minimal effect on the deflection of this cantilever. The mechanics of the bending and the chemistry of cantilever modification are discussed.

Journal Article↗

Origin of nanomechanical cantilever motion generated from biomolecular interactions.

Generation of nanomechanical cantilever motion from biomolecular interactions can have wide applications, ranging from high-throughput biomolecular detection to bioactuation. Although it has been suggested that such motion is caused by changes in surface stress of a cantilever beam, the origin of the surface-stress change has so far not been elucidated. By using DNA hybridization experiments, we show that the origin of motion lies in the interplay between changes in configurational entropy and intermolecular energetics induced by specific biomolecular interactions. By controlling entropy change during DNA hybridization, the direction of cantilever motion can be manipulated. These thermodynamic principles were also used to explain the origin of motion generated from protein-ligand binding.

DNA, Single-Stranded↗