Normal and shear strain estimation using beam steering on linear-array transducers.

In current ultrasound elastography, only the axial component of the displacement vector is estimated and used to produce strain images. A method was recently proposed by our group to estimate both the axial and lateral components of a displacement vector following a uniaxial compression. Previous work evaluated the technique using both simulations and a mechanically translated phased array transducer. In this paper, we present initial results using beam steering on a linear array transducer attached to a commercial scanner to acquire echo signals for estimating 2-D displacement vectors. Single-inclusion and anthropomorphic breast phantoms with different boundary properties between the inclusion and background material are imaged by acquiring echo data along beam lines ranging from -15 degrees to 15 degrees relative to the compression direction. 1-D cross-correlation is used to calculate "angular displacements" in each acquisition direction, yielding axial and lateral components of the displacement vector. Strain tensor components are estimated from these displacements. Features on shear strain images generated for the inclusion phantom agree with those predicted using FEA analysis. Experimental results demonstrate the utility of this technique on clinical scanners. Shear strain tensors obtained using this method may provide useful information for the differentiation of benign from malignant tumors. For the linear array transducer used in this study, the optimum angular increment is around 3 degrees. However, more work is required for the selection of an appropriate value for the maximum beam angle for optimal performance of this technique.

Humans↗

Semiautomated thermal lesion segmentation for three-dimensional elastographic imaging.

Several studies have demonstrated that lesion volumes computed from multiple planar slices through the region-of-interest (ROI) are more accurate than volumes estimated assuming simple shapes and incorporating single or orthogonal diameter estimates. However, manual delineation of boundaries on multiple planar 2-D images is tedious and labor-intensive. Automatic extraction of lesion boundaries is, therefore, attractive and imperative to remove subjectivity and reduce assessment time. This paper presents a semiautomated segmentation algorithm for thermal lesions on 3-D elastographic data to obtain both area and volume information. The semiautomated segmentation algorithm is based on thresholding and morphologic opening of both 2-D and 3-D elastographic data. Results obtained on 44 thermal lesions imaged in vitro using elastography were compared to manual delineation of both elastographic and pathology images. Results obtained using semiautomated segmentation demonstrate a close correspondence with manual delineation results. However, area and volume estimates obtained using both manual and semiautomated segmentation of lesions seen on elastograms slightly underestimate areas and volumes measured from pathology.

Algorithms↗

Estimation of displacement vectors and strain tensors in elastography using angular insonifications.

In current practice, only one out of three components of the tissue displacement vector and one of nine components of the strain tensor are accurately estimated and imaged in ultrasound elastography. Since, only the axial component of both the displacement and strain are imaged, other important elastic parameters, such as shear strains and the Poisson's ratio, also are not imaged. Moreover, reconstruction of the Young's modulus would be significantly improved if all components of the strain tensor were available. In this paper, we describe a new method for estimating all the components of the tissue displacement vector following a quasi-static compression. The method uses displacements estimated from radiofrequency echo-signals along multiple ultrasound beam insonification directions. At each spatial location in the compressed medium, orthogonal tissue displacements in both the axial and lateral direction with respect to the direction of the applied compression are estimated by curve fitting angular displacement vector data calculated for all insonification directions. Following displacement estimation in orthogonal directions, components of the corresponding normal and shear strain tensors are estimated. Simulation and experimental results demonstrate the utility of this technique for the computation of the normal and shear strain tensors.

Algorithms↗

Temperature dependence of ultrasonic propagation speed and attenuation in excised canine liver tissue measured using transmitted and reflected pulses.

Previous reported data from our laboratory demonstrated the temperature dependence of propagation speed and attenuation of canine tissue in vitro at discrete temperatures ranging from 25 to 95 degrees C. However, concerns were raised regarding heating the same tissue specimen over the entire temperature range, a process that may introduce irreversible and, presumably, cumulative tissue degradation. In this paper propagation speed and attenuation vs temperature are measured using multiple groups of samples, each group heated to a different temperature. Sample thicknesses are measured directly using a technique that uses both transmitted and reflected ultrasound pulses. Results obtained using 3 and 5 MHz center frequencies demonstrate a propagation speed elevation of around 20 m/s in the 22-60 degrees C range, and a decrease of 15 m/s in the 60-90 degrees C range, in agreement with previous results where the same specimens were subjected to the entire temperature range. However, sound speed results reported here are slightly higher than those reported previously, probably due to more accurate measurements of sample thickness in the present experiments. Results also demonstrate that while the propagation speed varies with temperature, it is not a function of tissue coagulation. In contrast, the attenuation coefficient depends on both tissue coagulation effects and temperature elevation.

Animals↗

Real-time calibration of temperature estimates during radiofrequency ablation.

Radiofrequency ablation is an interstitial focal ablative therapy that can be used in a percutaneous fashion and permits in situ destruction of hepatic tumors. Recurrence rates after rf therapy are as high as 34-55%, due to difficulties in accurately identifying the zone of necrosis (thermal lesion) because of the low intrinsic acoustic contrast between normal and ablated liver tissue. Our goal is to provide real-time ultrasonic tracking of temperature changes over the large range of temperatures traditionally used (40-100 degrees C) in rfablation procedures using an external ultrasound transducer. Temperature estimates are obtained using a cross-correlation algorithm applied to rf ultrasound echo signal data acquired at discrete intervals during heating. Apparent tissue displacement estimates obtained at these discrete time-intervals are accumulated to obtain a cumulative displacement map, whose gradient provides after appropriate scaling provides a temperature map at the specified elapsed ablation duration. Temperature maps are used to display the initial temperature rise and to continuously update a thermal map of the treated region. In this paper, we develop calibration curves that relate the echo shift due to the change in the speed of sound and thermal expansion to the corresponding temperature increase on in-vitro tissue specimens. These calibration curves can then be utilized for the real time calibration and analysis of temperature estimates obtained from the rf echo signals during ablation. Temperature maps obtained using the calibration curve compare favorably to temperature estimates observed using the invasive thermosensor readings on the ablation electrode and previous results that utilized a linear calibration factor.

Algorithms↗

Tissue-mimicking oil-in-gelatin dispersions for use in heterogeneous elastography phantoms.

A ten-month study is presented of materials for use in heterogeneous elastography phantoms. The materials consist of gelatin with or without a suspension of microscopic safflower oil droplets. The highest volume percent of oil in the materials is 50%. Thimerosal acts as a preservative. The greater the safflower oil concentration, the lower the Young's modulus. Elastographic data for heterogeneous phantoms, in which the only variable is safflower oil concentration, demonstrate stability of inclusion geometry and elastic strain contrast. Young's modulus ratios (elastic contrasts) producible in a heterogeneous phantom are as high as 2.7. The phantoms are particularly useful for ultrasound elastography. They can also be employed in MR elastography, although the highest achievable ratio of longitudinal to transverse relaxation times is considerably less than is the case for soft tissues.

Elasticity↗

Correction for simultaneous catheter eccentricity and tilt in intravascular elastography.

Intravascular elastography can provide significant new information about the elastic properties of vascular tissue and plaque, useful for the diagnosis of disease and appropriate selection of interventional methods. Knowledge of the plaque composition, vulnerability and its elastic properties can assist the clinician in selecting appropriate interventional techniques. However, several noise sources have to be addressed to obtain quality intravascular elastograms. Misalignment of the vessel lumen and the ultrasound beam can produce erroneous strain estimates in elastography. Errors in the strain estimate are introduced due to the eccentricity and tilt of the intravascular transducer within the vessel lumen. Previous work in this area has provided theoretical expressions for the correction of eccentricity and tilt errors when they occur independent of each other. However, under most imaging conditions, both eccentricity and tilt errors are simultaneously present. In this paper, we extend the theoretical correction factor by accounting for the influence of both of these errors occurring simultaneously in the positioning of the catheter within the vessel lumen.

Blood Vessels↗

Ultrasound monitoring of temperature change during radiofrequency ablation: preliminary in-vivo results.

Radiofrequency (RF) ablation is an interstitial focal ablative therapy that can be used in a percutaneous fashion and permits in situ destruction of hepatic tumors. However, local tumor recurrence rates after RF ablative therapy are as high as 34% to 55%, which may be due in part to the inability to monitor accurately temperature profiles in the tissue being ablated, and to visualize the subsequent zone of necrosis (thermal lesion) formed. The goal of the work described in this paper was to investigate methods for the real-time and in vivo monitoring of the spatial distribution of heating and temperature elevation to achieve better control of the degree of tissue damage during RF ablation therapy. Temperature estimates are obtained using a cross-correlation algorithm applied to RF ultrasound (US) echo signal data acquired at discrete intervals during heating. These temperature maps were used to display the initial temperature rise and to continuously update a thermal map of the treated region. Temperature monitoring is currently performed using thermosensors on the prongs (tines) of the RF ablation probe. However, monitoring the spatial distribution of heating is necessary to control the degree of tissue damage produced.

Animals↗

Elastographic imaging using a handheld compressor.

Elastography is an emerging imaging modality that allows noninvasive imaging of tissue stiffness changes and stiffness values associated with pathology or as a result of therapy. However, many currently-used systems for elastography rely on a fixed geometry transducer and compressor system for imaging. This configuration is disadvantageous for imaging difficult-to-reach regions that are currently accessible with conventional ultrasound. In this paper, we describe a handheld, portable stepper motor controlled system for elastography. This system may reduce motion and jitter errors that are prevalent in completely 'freehand elastography' that employs hand-induced compressions using the transducer. The latter also requires collection of large amounts of data and use of strain estimation algorithms that may not be sensitive to phase changes or use additional preprocessing to minimize decorrelation effects. The stepper motor controlled handheld system provides controlled compressions and synchronized data acquisition. Our technique yields elastograms of a low-contrast phantom that have contrast levels and contrast-to-noise ratios that are comparable to those obtained with a fixed geometry system.

Animals↗

Temperature dependence of ultrasonic propagation speed and attenuation in canine tissue.

Previously reported data on the temperature dependence of propagation speed in tissues generally span only temperature ranges up to 60 degrees C. However, with the emerging use of thermal ablative therapies, information on variation in this parameter over higher temperature ranges is needed. Measurements of the ultrasonic propagation speed and attenuation in tissue in vitro at discrete temperatures ranging from 25 to 95 degrees C was performed for canine liver, muscle, kidney and prostate using 3 and 5 MHz center frequencies. The objective was to produce information for calibrating temperature-monitoring algorithms during ablative therapy. Resulting curves of the propagation speed vs. temperature for these tissues can be divided into three regions. In the 25-40 degrees C range, the speed of sound increase rapidly with temperature. It increases moderately with temperature in the 40-70 degrees C range, and it then decreases with increasing temperature from 70-95 degrees C. Attenuation coefficient behavior with temperature is different for the various tissues. For liver, the attenuation coefficient is nearly constant with temperature. For kidney, attenuation increases approximately linearly with temperature, while for muscle and prostate tissue, curves of attenuation vs. temperature are flat in the 25-50 degrees C range, slowly rise at medium temperatures (50-70 degrees C), and level off at higher temperatures (70-90 degrees C). Measurements were also conducted on a distilled degassed water sample and the results closely follow values from the literature.

Animals↗

Phase aberration effects in elastography.

In sonography, phase aberration plays a role in the corruption of sonograms. Phase aberration does not have a significant impact on elastography, if statistically similar phase errors are present in both the pre- and postcompression signals. However, if the phase errors are present in only one of the pre- or postcompression signal pairs, the precision of the strain estimation process will be reduced. In some cases, increased phase errors may occur only in the postcompression signal due to changes in the tissue structure with the applied compression. Phase-aberration effects increase with applied strain and may be viewed as an image quality derating factor, much like frequency-dependent attenuation or undesired lateral tissue motion. In this paper, we present a theoretical and simulation study of the effects of phase aberration on the elastographic strain-estimation process, using the strain filter approach.

Biomechanical Phenomena↗

Experimental corroboration of the nonstationary strain estimation errors in elastography.

The nonstationary variation in the noise performance of the cross-correlation-based strain estimator due to frequency-dependent attenuation and lateral and elevational signal decorrelation have been addressed theoretically in recent papers using the strain-filter approach. In this paper, we present the experimental verification and corroboration of the nonstationary effects on the strain estimation results. The accuracy and precision of the strain estimate deteriorates with lateral position in the elastogram, due to the lateral motion of tissue scatterers, and with depth, due to frequency-dependent attenuation. The results illustrate that the best strain-estimation noise performance is obtained in the focal zone of the transducer and around the axis of symmetry of the phantom.

Elasticity↗

Allogeneic transplantation induces expression of cytomegalovirus immediate-early genes in vivo: a model for reactivation from latency.

Reactivation of cytomegalovirus (CMV) from latency is a frequent complication of organ transplantation, and the molecular mechanism by which this occurs is unknown. Previous studies have shown that allogeneic stimulation induces reactivation of human CMV (HCMV) in vitro (64). We find that transplantation of vascularized allogeneic kidneys induces murine CMV (MCMV) and HCMV immediate-early (ie) gene expression. This induction is accompanied by increased expression of transcripts encoding inflammatory cytokines, including tumor necrosis factor (TNF), interleukin-2, and gamma interferon, and by activation of NF-kappaB. TNF alone can substitute for allogeneic transplantation in inducing HCMV and MCMV ie gene expression in some tissues. Our studies suggest that reactivation is a multistep process which is initiated by factors that induce ie gene expression, including TNF and NF-kappaB. Allogeneic transplantation combined with immunosuppression may be required to achieve complete reactivation in vivo.

Animals↗

Tradeoffs in elastographic imaging.

This paper presents the tradeoffs in elastographic imaging. Elastography is viewed as a new imaging modality and presented in terms of three fundamental concepts that constitute the basis for the elastographic imaging process. These are the tissue elastic deformation process, the statistical analysis of strain estimation and the image characterization. The first concept involves the use of the contrast transfer efficiency (CTE) that describes the mapping of a distribution of local tissue elastic moduli into a distribution of local longitudinal tissue strains. The second concept defines the elastographic system and the relationship between ultrasonic and signal processing parameters. This process is described in terms of a stochastic framework (the strain filter) that provides upper and practical performance bounds and their dependence on the various system parameters. Finally, the output image, the elastogram, is characterized by its image parameters, such as signal-to-noise ratio, contrast-to-noise ratio, dynamic range and resolution. Finite-element simulations are used to generate examples of elastograms that are confirmed by the theoretical prediction tools.

Acoustics↗

Spectral estimators in elastography.

Like velocity, strain induces a time delay and a time scaling to the received signal. Elastography typically uses time delay techniques to indirectly (i.e. via the displacement estimate) measure tissue strain induced by an applied compression, and considers time scaling as a source of distortion. More recently, we have shown that the time scaling factor can also be spectrally estimated and used as a direct measure of strain. Strain causes a Doppler-like frequency shift and a change in bandwidth of the bandpass power spectrum of the echo signal. Two frequency shift strain estimators are described that have been proven to be more robust but less precise when compared to time delay estimators, both in simulations and experiments. The increased robustness is due to the insensitivity of the spectral techniques to phase decorrelation noise. In this paper we discuss and compare the theoretical and experimental findings obtained with traditional time delay estimators and with the newly proposed spectral methods.

Blood Flow Velocity↗

Nonlinear stress-strain relationships in tissue and their effect on the contrast-to-noise ratio in elastograms.

The practice of elastography is generally limited to small applied compressions (typically 1%), under the assumption of a linear stress-strain relationship in biological tissue. However, the recent reports of larger applied compressions and precompression levels to increase the strain contrast violate the above assumption. The nonlinear stress-strain relationships in different breast tissue types significantly alter the contrast in elastography, especially for large applied compression. The moduli of normal fibrous and glandular breast tissue (along with cancerous lesions) are strain-dependent, with tissue stiffness increasing with applied compression. In this paper, we illustrate that the strain-dependence of the modulus has a significant impact on the elastographic contrast and on the contrast-to-noise ratio, and may even cause a reversal of the contrast in certain situations. This paper also emphasizes the effect of the precompression strain level on the strain contrast.

Breast↗

Direct strain estimation in elastography using spectral cross-correlation.

Spectral estimation of tissue strain has been performed previously by using the centroid shift of the power spectrum or by estimating the variation in the mean scatterer spacing in the spectral domain. The centroid shift method illustrates the robustness of the direct, incoherent strain estimator. In this paper, we present a strain estimator that uses spectral cross-correlation of the pre- and postcompression power spectrum. The centroid shift estimator estimates strain from the mean center frequency shift, while the spectral cross-correlation estimates the shift over the entire spectrum. Spectral cross-correlation is shown to be more sensitive to small shifts in the power spectrum and, thus, provides better estimation for smaller strains when compared to the spectral centroid shift. Spectral cross-correlation shares all the advantages gained using the spectral centroid shift, in addition to providing accurate and precise strain estimation for small strains. The variance and noise properties of the spectral strain estimators quantified by their respective strain filters are also presented.

Acoustics↗