Clinical and biological observations on working men.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to T W Clark.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We report two patients with arteriovenous hemodialysis fistulas that were complicated by brachial artery pseudoaneurysms. Each pseudoaneurysm was percutaneously thrombosed with an injection of thrombin, using techniques to prevent escape of thrombin into the native brachial artery. In one patient, an angioplasty balloon was inflated across the neck of the aneurysm during thrombin injection. In the second patient, thrombin was injected during ultrasound-guided compression of the neck of the pseudoaneurysm. Complete thrombosis of each pseudoaneurysm was achieved within 30 sec. No ischemic or embolic events occurred. This technique may be useful in treating pseudoaneurysms of smaller peripheral arteries.
Subtle ankle fractures may escape detection on plain radiography. These occult fractures can cause prolonged disability and pain. We present a case of blunt ankle trauma where plain radiography failed to reveal any bony abnormalities. The recognition of an ankle effusion on plain radiographs prompted us to perform a computed tomography (CT) scan of the ankle. The CT scan demonstrated an anterior plafond fracture of the distal tibia, which required surgical fixation. Had the fracture not been identified, our patient would have been treated inappropriately for a ligament sprain. An occult fracture should be suspected if an ankle is grossly swollen after blunt trauma, and plain radiography demonstrates an effusion. In this circumstance, performance of further imaging studies, such as conventional or CT, are advised to rule out an occult ankle fracture.
PURPOSE: To evaluate the use of stents for prolonging the patency of gastroenteric anastomoses (GEA) induced by magnet compression. MATERIALS AND METHODS: Rare earth magnets were inserted perorally and serially in 15 dogs so as to mate across the gastric and jejunal walls. After magnet excretion, the resulting GEA was identified endoscopically, dilated (n = 1), and stented with bare (n = 2) or partially covered (n = 6) flared 10-mm or 12-mm Z stents. The GEA was followed at 2-4-week intervals for patency; malfunctioning shunts were irrigated, or dilated with angioplasty balloons. Gross and histologic examination of the anastomotic tissues was performed in 14 animals. RESULTS: Magnet pairs were excreted in 5-7 days. Of the 19 magnet placements in 15 animals, stent placement was not possible because of early GEA closure (n = 6), failure to locate (n = 2), pancreatic abscess (n = 1), and magnet perforation with peritonitis (n = 1). Estimated duration of GEA patency was 19 days after balloon dilation, 40-64 days with bare Z stents, and 58-147 days (mean, 90 days) with partially covered Z stents. Shunt function was commonly hindered by bezoars. Stent narrowing or occlusion was caused by tissue overgrowth through bare stents (n = 2), between covered stent struts and through partially detached membrane (n = 2). Serious morbidity (n = 2) was due to malpositioned magnets across the pancreas in one animal and gastric perforation in the other. One dog was euthanized because of unsuspected kidney infection. CONCLUSION: Partially covered stents significantly extend the anatomic patency rate of magnetic GEA to 7 weeks or more. Functional patency is frequently impaired by bezoars. Ongoing improvements in covered stent design should provide longer-term GEA patency.