Adult presentation of metanephric stromal tumor.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to T W Jarrett.
Explore the source record for details and available documents.
We report a case of a 59-year-old man with recurrent bleeding after retroperitoneal laparoscopic nephrectomy. Computed tomography and Doppler ultrasonography confirmed an intercostal artery pseudoaneurysm as the source. Angiography 1 month later demonstrated resolution after conservative management.
PURPOSE: We evaluated the clinical efficacy of laparoscopic versus open radical nephrectomy in patients with clinically localized renal cell carcinoma. MATERIALS AND METHODS: Between 1991 and 1999, 67 laparoscopic radical nephrectomies were performed for clinically localized, stages cT1/2 NXMX, pathologically confirmed renal cell carcinoma. During this period 54 patients who underwent open radical nephrectomy with pathologically confirmed stages pT1/2 NXMX disease were also identified. Medical and operative records were retrospectively reviewed and telephone followup was done to assess patient status. RESULTS: In the laparoscopic and open groups average tumor size was 5.1 (range 1 to 13) and 5.4 cm. (range 0.2 to 18), respectively, which was not statistically significant. No patient had laparoscopic port site, wound or renal fossa tumor recurrence in either group. All patients were followed at least 12 months. In the laparoscopic group 2 cancer specific deaths occurred at a mean followup of 35.6 months. In the open group there were 2 cancer specific deaths and 3 cases of disease progression at a mean followup of 44 months. Kaplan-Meier disease-free survival and actuarial survival analysis revealed no significant differences in the laparoscopic and open radical nephrectomy groups. Also, no differences were noted in the complication rate. CONCLUSIONS: Laparoscopic radical nephrectomy is an effective alternative for localized renal cell carcinoma when the principles of surgical oncology are maintained. Initial data show shorter patient hospitalization and effective cancer control with no significant difference in survival compared with open radical nephrectomy.
OBJECTIVES: To establish the safety and efficacy of laparoscopic and laparoscopic-assisted nephroureterectomy. METHODS: Since 1993, 25 patients with a minimum of 12 months of follow-up underwent nephroureterectomy using a total laparoscopic or laparoscopic-assisted technique. Four patients had specimen morcellation for tissue removal. All patients had regular follow-up with physical examinations, interval cystoscopy, and radiographs, depending on the metastatic potential of the tumor. Retrospective chart review was performed and assessed for operative time, blood loss, tumor pathologic stage, complications, and outcome. One patient was excluded because of an open conversion due to multiple previous abdominal surgeries and failure to progress. RESULTS: The mean operating time was 329 minutes but decreased with experience. The median hospital stay was 4 days. Tumor stage was directly related to tumor grade. Associated bladder tumors (prior history or recurrent tumors) occurred in 50% of the patients. Ipsilateral ureteral stump site recurrence occurred in 1 patient. Although no port site seeding occurred, 1 patient, whose tumor was discovered histologically after laparoscopic pyeloplasty for presumed benign disease, developed recurrence in the renal fossa and metastatic disease. Two patients developed liver metastasis. CONCLUSIONS: Total laparoscopic and laparoscopic-assisted nephroureterectomy are acceptable alternatives to open surgery in the treatment of transitional cell carcinoma of the upper urinary tract. Tumor morcellation did not appear to adversely affect patient outcome. As with open nephroureterectomy, tumor grade is the most important prognostic indicator of local, bladder, and metastatic recurrence. No port site seeding was observed in either the total laparoscopic or laparoscopic-assisted groups.
OBJECTIVES: The techniques for hemostasis after renal tumor excision have limited the widespread application of laparoscopic partial nephrectomy (LPN). To improve hemostasis and aid visualization, we report our experience with a novel radiofrequency coagulation (RFC) technique for LPN. METHODS: Ten patients underwent RFC-assisted LPN. The demographic and perioperative data were tabulated. Patients were positioned as for laparoscopic nephrectomy, and laparoscopic ports were placed. The kidney within Gerota's fascia was mobilized, and the fat overlying the tumor was carefully removed for pathologic evaluation. Under laparoscopic guidance, a radiofrequency probe was percutaneously inserted into the lesion and deployed to coagulate the lesion and a margin of normal parenchyma. Laparoscopic scissors were used to excise the lesion; additional hemostatic maneuvers were used selectively. RESULTS: The mean renal tumor size was 2.1 cm (range 1.0 to 3.2). The median operative time was 170 minutes and the median blood loss was 125 mL. The RFC technique resulted in complete tissue coagulation within the treated volume, thereby facilitating intraoperative visualization, minimizing blood loss, and permitting rapid and controlled tumor resection. The renal architecture was preserved, allowing accurate diagnosis of renal cell carcinoma and angiomyolipoma in 9 and 1 cases, respectively. No perioperative complications occurred. CONCLUSIONS: The use of RFC is an effective method to facilitate LPN of both exophytic and endophytic masses. By coagulating a margin of normal parenchyma, the technique minimizes blood loss and improves visualization during LPN. We anticipate this technique will broaden the clinical application for LPN.
OBJECTIVES: To assess the safety and efficacy of laparoscopic ablation of symptomatic renal cysts as minimally invasive therapeutic techniques have largely supplanted open surgical intervention for the treatment of symptomatic renal cysts. METHODS: The records of 32 consecutive adult patients who underwent laparoscopic ablation of renal cysts (11 peripelvic, 21 parenchymal) were retrospectively reviewed. All patients were symptomatic at presentation; 26 had a single cyst, 5 had two cysts, and 1 had four cysts. RESULTS: Twenty patients underwent a transperitoneal laparoscopic approach, and 12 patients underwent a retroperitoneal laparoscopic approach. An average of 3.2 ports were used for each procedure, and no open conversions or transfusions were necessary. When comparing patients with parenchymal and peripelvic cysts, statistically significant differences were noted in the mean operative time (164 versus 233 minutes, respectively; P = 0.003) and mean operative blood loss (98 versus 182 mL, respectively; P = 0.04). Four patients (13%) had complications (one major and three minor), including a persistent ureteral stricture. One patient with negative preoperative aspiration cytology and negative intraoperative frozen section analysis was later found to have malignancy within the cyst wall, necessitating radical nephrectomy and trocar site excision. One patient (3%) developed a recurrence. CONCLUSIONS: Laparoscopic ablation of symptomatic renal cysts is a safe and efficacious procedure. We report an overall complication rate of 13% and a recurrence rate of 3% with a mean follow-up of 18.1 months (median 10.0).
Although nephroureterectomy remains the reference standard for the treatment of transitional cell cancer of the renal pelvis, advances in technology and techniques have made percutaneous management of select lesions feasible. We report our technique of staged percutaneous resection of a large renal pelvic transitional cell cancer.
BACKGROUND AND PURPOSE: To decrease postoperative dependence on narcotics for analgesia, we have evaluated ketorolac as an adjunct to perioperative pain control in patients undergoing laparoscopic urologic surgery. PATIENTS AND METHODS: Sixty-five patients (34 male, 31 female) were randomized to receive either ketorolac tromethamine (15-30 mg IV q 6 h) or placebo prior to laparoscopic surgery. Patient-controlled analgesia in the form of morphine sulfate was provided. Operative factors such as the type of surgery, operative time, and estimated blood loss were recorded. Postoperative factors such as analog pain score (range 0-10), narcotic usage, and length of stay were evaluated. RESULTS: Fifty-five patients completed the study. The average pain score was 2.2 and 4.5 for the ketorolac and placebo groups, respectively (P < 0.005). The mean amounts of total morphine used were 39.2 mg (ketorolac) and 62.5 mg (placebo) (P = 0.077). The length of stay was not significantly different in the ketorolac (2.5 days) and placebo (2.6 days) groups (P = 0.74). Operative times (P = 0.21) and estimated blood loss (P = 0.60) were not significantly different in the two groups. Ketorolac did not adversely affect renal function; serum creatinine changes were not significantly different from those in the patients receiving placebo (P = 0.50). Laparoscopic pyeloplasty necessitated more narcotic analgesia than did other laparoscopic procedures (P = 0.05). CONCLUSION: Ketorolac decreases the subjective perception of pain after laparoscopic urologic surgery. It is suggested that ketorolac administration decreases the amount of narcotic usage as well. Time to resumption of oral intake and length of hospital stay were not influenced by use of ketorolac.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
PURPOSE: The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. MATERIALS AND METHODS: The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. RESULTS: The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. CONCLUSIONS: A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.
Explore the source record for details and available documents.
Laparoscopic procedures are performed using general anesthesia due to the perceived limitations of regional anesthesia in the upper abdomen and retroperitoneum. We present our initial experience with epidural anesthesia for retroperitoneal laparoscopic renal biopsy.
BACKGROUND: Telementoring allows a less experienced surgeon to benefit from an expert surgical consultation, reducing cost, travel, and the learning curve associated with new procedures. However, there are several technical limitations that affect practical applications. One potentially serious problem is the time delay that occurs any time data are transferred across long distances. To date, the effect of time delay on surgical performance has not been studied. MATERIALS AND METHODS: A two-phase trial was designed to examine the effect of time delay on surgical performance. In the first phase, a series of tasks was performed, and the numbers of robotic movements required for completion was counted. Programmed incremental time delays were made in audiovisual acquisition and robotic controls. The number of errors made while performing each task at various time delay intervals was noted. In the second phase, a remote surgeon in Baltimore performed the tasks 9000 miles away in Singapore. The number of errors made was recorded. RESULTS: As the time delay increased, the number of operator errors increased. The accuracy needed to perform remote robotic procedures was diminished as the time delay increased. A learning curve did exist for each task, but as the time delay interval increased, it took longer to complete the task. CONCLUSIONS: Time delay does affect surgical performance. There is an acceptable delay of <700 msec in which surgeons can compensate for this phenomenon. Clinical studies will be needed to evaluate the true impact of time delay.
Standard percutaneous nephrolithotomy is highly effective for the removal of renal calculi. However, significant morbidity has been associated with this procedure. Consequently, many urologists inappropriately defer to a less effective procedure to reduce patient morbidity. This practice may increase the total number of procedures needed for treatment and result in a substantial increase in health care costs. Mini-percutaneous nephrolithotomy using a 13F ureteroscopy sheath is described to reduce the morbidity associated with standard percutaneous nephrolithotomy while maintaining its efficiency and effectiveness for stone removal. The indications and technique for mini-percutaneous nephrolithotomy and our results are summarized.
BACKGROUND AND PURPOSE: Telemedicine is the use of telecommunication technology to deliver healthcare. Telementoring has been developed to allow a surgeon at a remote site to offer guidance and assistance to a less-experienced surgeon. We report on our experience during laparoscopic urologic procedures with mentoring between Rome, Italy, and Baltimore, USA. MATERIAL AND METHODS: Over a period of 3 months, two laparoscopic left spermatic vein ligations, one retroperitoneal renal biopsy, one laparoscopic nephrectomy, and one percutaneous access to the kidney were telementored. Transperitoneal laparoscopic cases were performed with the use of AESOP, a robotic for remote manipulation of the endoscopic camera. A second robot, PAKY, was used to perform radiologically guided needle orientation and insertion for percutaneous renal access. In addition to controlling the robotic devices, the system provided real-time video display for either the laparoscope or an externally mounted camera located in the operating room, full duplex audio, telestration over live video, and access to electrocautery for tissue cutting or hemostasis. RESULTS: All procedures were accomplished with an uneventful postoperative course. One technical failure occurred because the robotic device was not properly positioned on the operating table. The round-trip delay of image transmission was less than 1 second. CONCLUSION: International telementoring is a feasible technique that can enhance surgeon education and decrease the likelihood of complications attributable to inexperience with new operative techniques.
Explore the source record for details and available documents.
Explore the source record for details and available documents.