PubMed Health⌕ Search

Biomedical subjects

T W Kornack

Publications and source records attributed to T W Kornack.

4 recordsLinked to original sources

Nuclear spin gyroscope based on an atomic comagnetometer.

We describe a nuclear spin gyroscope based on an alkali-metal-noble-gas comagnetometer. Optically pumped alkali-metal vapor is used to polarize the noble-gas atoms and detect their gyroscopic precession. Spin precession due to magnetic fields as well as their gradients and transients can be cancelled in this arrangement. The sensitivity is enhanced by using a high-density alkali-metal vapor in a spin-exchange relaxation free regime. With a K-3He comagnetometer we demonstrate rotation sensitivity of 5 x 10(-7) rad s(-1) Hz(-1/2), equivalent to a magnetic field sensitivity of 2.5 fT/Hz(1/2). The rotation signal can be increased by a factor of 10 using 21Ne with a smaller magnetic moment. The comagnetometer is also a promising tool in searches for anomalous spin couplings beyond the standard model.

Journal Article↗

A subfemtotesla multichannel atomic magnetometer.

The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.

Magnetics↗

Dynamics of two overlapping spin ensembles interacting by spin exchange.

We describe linear and nonlinear dynamics of spin-polarized K and 3He ensembles interacting by spin exchange. The interactions are dominated by the imaginary part of the spin-exchange cross section and each spin species is primarily affected by the average magnetization of the other. Operating in a very low magnetic field we demonstrate novel dynamics when the electron and nuclear spin precession frequencies are nearly matched. We observe transverse damping as well as a dynamic instability of the 3He spins interacting with polarized K vapor. We also demonstrate operation as a self-compensating comagnetometer, useful for tests of CPT violation and other precision measurements.

Journal Article↗

High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation.

Alkali-metal magnetometers compete with SQUID detectors as the most sensitive magnetic field sensors. Their sensitivity is limited by relaxation due to spin-exchange collisions. We demonstrate a K magnetometer in which spin-exchange relaxation is completely eliminated by operating at high K density and low magnetic field. Direct measurements of the signal-to-noise ratio give a magnetometer sensitivity of 10 fT Hz(-1/2), limited by magnetic noise produced by Johnson currents in the magnetic shields. We extend a previous theoretical analysis of spin exchange in low magnetic fields to arbitrary spin polarizations and estimate the shot-noise limit of the magnetometer to be 2x10(-18) T Hz(-1/2).

Magnetics↗