PubMed Health⌕ Search

Biomedical subjects

T Wakaguri

Publications and source records attributed to T Wakaguri.

4 recordsLinked to original sources

[Detection of parafoveal scotoma by multifocal electroretinograms].

We investigated the relation between multifocal electroretinograms (M-ERGs) and artificial parafoveal scotoma. M-ERGs were recorded from normal subjects using a circular piece of black paper attached to a monitor. Lower response density around the 10 to 15 degree parafovea region was not observed up to 3 degree scotoma (visual angle), but was detected above 5 degree scotoma in field topography of M-ERGs. The shape of the scotoma in field topography was not circular but somewhat oval. The results from two cases of parafoveal retinal degeneration were in good accordance with this basic study in normal subjects. We proved that detection of parafoveal scotoma by M-ERG is limited in comparison with the results obtained by automated static perimetry.

Electroretinography↗

Relationship between visual field defect and multifocal electroretinogram.

We investigated the effect of artificial parafoveal scotomata on the multifocal electroretinogram (M-ERG). M-ERGs were recorded from normal subjects using a monitor with several different sizes of black paper attached. A lower response density area around the 10 to 15 degree parafoveal region was not recognized for scotomata up to 3 degrees but was observed in scotomata above 5 degrees (visual angle) in the field topography of M-ERG. The shape of the scotomata was not circular but somewhat oval. The results from two cases of parafoveal retinal degeneration accorded well with this basic study.

Adult↗

A basic investigation of multifocal electroretinogram: reproducibility and effect of luminance.

PURPOSE: To investigate the reproducibility as well as the effect of luminance in multifocal electroretinogram (mERG). METHODS: Multifocal electroretinogram recordings were repeated on different days in 6 normal subjects using the Veris III system. The mean luminance of the monitor displaying the stimuli was randomly varied by five kinds of neutral density (ND) filters. RESULTS: The standard deviation of mERG amplitude from the macular region was approximately 10% of the mean value for each normal subject. Reproducibility largely depended on the condition of the subject and placement of the contact lens electrode. With decreases in the mean luminance of the monitor, the amplitude of mERG decreased exponentially, whereas the peak latency increased linearly. mERGs elicited from a patient with mild cortical cataract resembled the mERGs obtained from the control group using an ND filter between -0.30 and -0.52 log, whereas two patients with typical retinitis pigmentosa showed much lower response densities in mERGs. CONCLUSIONS: It is necessary to pay attention to the reproducibility and the luminance effect to obtain reliable mERGs.

Adult↗