PubMed Health⌕ Search

Biomedical subjects

T Whitman

Publications and source records attributed to T Whitman.

9 recordsLinked to original sources

Comparison of coronary venous defibrillation with conventional transvenous internal defibrillation in man.

OBJECTIVE: Animal studies have shown that defibrillation in coronary veins is more effective than in the right ventricle. We aimed to assess the feasibility of placing defibrillation electrodes in the middle cardiac vein (MCV) in man and its impact on defibrillation requirements. METHODS: A prospective randomised study conducted in a tertiary referral centre. 10 patients (9 male) undergoing ICD implantation (65 (12) yrs) for NASPE/BPEG indications were studied. Defibrillation thresholds (DFT) were measured, using a binary search and an external defibrillator after 10 seconds of ventricular fibrillation, for the following configurations in each patient (order of testing randomised): RV + MCV --> Can and RV --> SVC + Can. INTERVENTIONS: A dual coil defibrillation electrode was placed transvenously in the right ventricle (RV) in the conventional manner. Using a guiding catheter a 3.2 Fr (67.5 mm length) electrode was placed transvenously in MCV. A test-can was placed subcutaneously in the left pectoral region. RESULTS: Lead placement was possible in 8/10 pts. Time to perform a middle cardiac venogram and place the electrode was 21 (23) mins. No adverse events were observed. Defibrillation current was less (6.7 (2.7) A) with RV + MCV --> Can compared to the conventional RV --> SVC + Can configuration (8.9 (3.4) A, p = 0.03). There was no significant difference in defibrillation voltage or energy. However, shock impedance was higher in the former configuration (57 (10) v. 43 (6) Omega, p = 0.001). CONCLUSIONS: In the majority of cases placement of a defibrillation lead in MCV is feasible. Defibrillation current requirements are 25% less when the shock is delivered using a MCV electrode.

Aged↗

Increased defibrillation threshold with right-sided active pectoral can.

UNLABELLED: The aim of this study was to identify the optimal position on the chest wall to place an implant able cardioverter defibrillator in a two-electrode system, consisting of a right ventricular electrode and active can. METHODS AND RESULTS: Defibrillation thresholds (DFT) were measured in 10 anaesthetised pigs (weight 33-45 kg). An Angeflextrade mark lead was introduced transvenously to the right ventricular apex. The test-can (43 cc) was implanted submuscularly in each of four locations: left pectoral (LP), right pectoral (RP), left lateral (LL) and apex (A). The sequence in which the four locations were tested was randomized. Ventricular fibrillation (VF) was induced using 60 Hz alternating current. Rectangular biphasic shocks were delivered 10 seconds after VF induction. The DFT was measured using a modified four-reversal binary search. The results of the four configurations were: LP, 14.6+/- 4.0 J; RP, 18.8+/- 4.2 J; LL, 14.7+/- 4.1 J; A, 14.9+/- 3.1 J. Repeated measures analysis of variance showed that the DFT of RP was significantly higher than LP, LL and A (p < 0.05). CONCLUSIONS: Implanting an active can in the RP position increases the DFT by 29% compared to LP, LL and A sites. The can position on the left thorax does not appear to have a significant influence on DFT.

Animals↗

Reduction in defibrillation threshold using an auxiliary shock delivered in the middle cardiac vein.

Defibrillation in the middle cardiac vein (MCV) has been shown to reduce ventricular defibrillation thresholds (DFTs). Low amplitude auxiliary shock (AS) from an electrode sutured to the left ventricle at thoracotomy have also been shown to reduce DFT if delivered immediately prior to a biphasic shock (between the ventricular RV and superior vena caval (SVC) electrodes). This study investigates the impact on DFT of an AS shock from a transvenously placed MCV lead system. A standard defibrillation electrode was positioned in the RV in eight anesthetized pigs (35-43 kg). A 50 x 1.8-mm electrode was inserted in the MCV through an 8 Fr angioplasty guide catheter. A 150-V (leading edge) monophasic AS was delivered (95 microF capacitor) from the MCV-->Can with three different pulse widths (3, 5, 7 ms). A primary biphasic shock (PS) (95 microF capacitor, phase 1: 44% tilt, 1.6-ms extension and phase 2: 2.5-ms fixed duration) was delivered from the RV-->Can +/- AS. The four configurations were randomized and DFTs (PS + AS) assessed using a modified binary search. Ventricular fibrillation (VF) was induced with 60 Hz AC followed 10 seconds later by the test shock. The DFTs were compared using repeated measures analysis of variance (ANOVA). All configurations incorporating AS produced significant (P < 0.05) reduction in the DFT compared to no AS (13.8 +/- 7.4 J). There was no difference in the efficacy of differing pulse widths (P > 0.05); 3 ms (11.0 +/- 5.4 J), 5 ms (11.5 +/- 6.0), and 7 ms (10.6 +/- 5.3 J). In conclusion, delivering an AS from a transvenous lead system deployed in the MCV reduces the DFT by 23% compared to a conventional RV-->Can shock alone.

Analysis of Variance↗

Performance characteristics of rapid (30-second) prescreening. Implications for calculating the false-negative rate and comparison with other quality assurance techniques.

Rapid (30-second) prescreening of cervicovaginal smears can be used to detect false-negative cases and determine the false-negative rate of primary screening, but the performance characteristics have not been evaluated fully. A test set of 242 cases including 80 originally false-negative cases were rapidly screened by 4 different cytotechnologists on 2 occasions. Intraobserver and interobserver reproducibility were good. Median specificity for each round of observations was 89% (range, 30%-96%). Median sensitivity for all true-positive cases was 78% (range, 63%-97%); for all false-negative cases it was 59% (range, 38%-89%). The relative sensitivity of rapid screening for true-positive and false-negative cases varied with the diagnosis. Rapid screening detected almost the same percentage of false-negative cases of atypical squamous cells of uncertain significance (ASCUS) as true-positive ASCUS cases (median ratio, 1.12; range, 0.72-1.52). The median ratio of false-negative to true-positive ASCUS cases was significantly different than the ratio for low-grade plus high-grade squamous intraepithelial lesions (0.68; range, 0.50-0.96). Although performance varies between individuals, in this test population the reproducibility, specificity, and sensitivity were good. Because it detects more false-negative cases at a lower cost per case than routine rescreening, rapid prescreening should be considered as an alternative to current quality control measures.

False Negative Reactions↗

Design of ICUs.

Explore the source record for details and available documents.

Environment Design↗

Teaching interactive signing in a dialogue situation to mentally retarded individuals.

Verbal prompts, modeling, physical guidance, positive reinforcement, fading, and chaining procedures were used to teach two nonverbal individuals, one severely and one moderately mentally retarded, an interactive signing dialogue in a naturalistic snack time setting. Both were required to initiate signed communication and to respond to signed communication with either action or manual signing. Using a multiple probe design across three dialogue situations, each client was successively taught his role in each dialogue with a staff member serving as his partner. After both trainees had mastered a dialogue role, signing competency was formally probed as they interacted with their staff partner in a maintenance situation and with the other trainee in a generalization situation. Results showed that clients could learn to use signed communication in each dialogue situation but that extensive training was required. Data also indicated that only partial generalization to the client-client situation occurred.

Adolescent↗

Significance of cell groups in voided urine.

OBJECTIVE: To determine the significance of different types of cell groups in voided urine for diagnosing transitional cell carcinoma (TCC). STUDY DESIGN: We reviewed voided urine specimens, with corresponding biopsies taken within 120 days after urine collection, for cell groups. Type and number of cell groups were correlated with the histologic diagnoses. RESULTS: Of 5,001 voided urine specimens, 134 (3%) had corresponding biopsies. Flat sheets were significantly more common in urine specimens with corresponding negative biopsies (24%) than in those with biopsies showing TCC (6%) (chi 2 P = .0032). The incidence of collared, three-dimensional cell groups was low (0-7%) and not associated with biopsy findings. Irregular, three-dimensional cell groups were more common than collared cell groups and were most common in cases with invasive TCC on biopsy (38%). While this was statistically significantly more common than in urines associated with negative biopsies (17%) (chi 2 P = .0499), it was not specific. Requiring three or more irregular cell groups did not improve discrimination between TCC and benign cases. Cell groups of any type or number were not more common in cases associated with grade 1 papillary TCC than negative biopsies. Diagnoses associated with multiple irregular, three-dimensional cell groups and a negative biopsy included medullary sponge kidney, hemorrhagic cystitis, cystitis not otherwise specified, and urolithiasis. CONCLUSION: Irregular, three-dimensional cell groups were most common in voided urine from patients with invasive TCC, but the identification of cell groups of any type in voided urine had little diagnostic utility.

Adult↗