PubMed Health⌕ Search

Biomedical subjects

T Wohland

Publications and source records attributed to T Wohland.

5 recordsLinked to original sources

Mapping the antagonist binding site of the serotonin type 3 receptor by fluorescence resonance energy transfer.

We have measured fluorescence resonance energy transfer (FRET) between a fluorescent antagonist, bound to the purified detergent-solubilized serotonin type 3 receptor, and a lipophilic acceptor probe partitioned into the micelle surrounding the detergent-solubilized receptor. The experimentally observed FRET efficiency was evaluated on the basis of the characteristic dimensions of the receptor-micelle complex and the average number of acceptor molecules in such micelles. The binding site was determined to be 5.4 +/- 0.9 nm above the center of the detergent micelle. The experiments were performed below the critical micellar concentration of the detergent (C(12)E(9)) used to solubilize the receptor, under which conditions it was demonstrated that the ligand binding activity was fully preserved. This reduces considerably the fluorescence background arising from probes not associated with the receptor, allowing a precise determination of the transfer efficiency.

Animals↗

The standard deviation in fluorescence correlation spectroscopy.

The standard deviation (SD) in fluorescence correlation spectroscopy (FCS) has been mostly neglected in applications. However, the knowledge of the correct SD is necessary for an accurate data evaluation, especially when fitting theoretical models to experimental data. In this work, an algorithm is presented that considers the essential features of FCS. It allows prediction of the performance of FCS measurements in various cases, which is important for finding optimal experimental conditions. The program calculates the SD of the experimental autocorrelation function online. This procedure leads to improved parameter estimation, compared to currently used theoretical approximations for the SD. Three methods for the calculation of the SD are presented and compared to earlier analytical solutions (D. E. Koppel. 1974. Phys. Rev. A. 10:1938-1945.), calculation directly from fluorescence intensity values, by averaging several FCS measurements, or by dividing one measurement into a set of shorter data packages. Although the averaging over several measurements yields accurate estimates for the SD, the other two methods are considerably less time consuming, can be run online, and yield comparable results.

Computer Simulation↗

Fluorescence techniques: shedding light on ligand-receptor interactions.

The ability of organisms, or individual cells, to react to external chemical signals, which are detected and transduced by cell-surface receptors, is crucial for their survival. These receptors are the targets of the majority of clinically used medicines. Combinatorial genetics can provide almost unlimited numbers of mutant receptor proteins and combinatorial chemistry can produce large libraries of potential therapeutic compounds that act on these membrane receptors. What is missing for the fundamental understanding of receptor function and for the discovery of new medicines are efficient procedures to screen both ligand-receptor interactions and the subsequent functional consequences. Ultrasensitive fluorescence spectroscopic approaches, in combination with efficient labelling protocols, offer enormous possibilities for highly parallel functional bioanalytics at the micro- and nanometer level.

Animals↗

Study of ligand-receptor interactions by fluorescence correlation spectroscopy with different fluorophores: evidence that the homopentameric 5-hydroxytryptamine type 3As receptor binds only one ligand.

The 5-hydroxytryptamine receptor of type 3 was investigated by fluorescence correlation spectroscopy (FCS). Binding constants of fluorescently labeled ligands, the stoichiometry, and the mass of the receptor are readily accessible by this technique, while the duration of measurement is on the order of seconds to minutes. The receptor antagonist 1,2,3, 9-tetrahydro-3-[(5-methyl-1H-imidazol-4-yl)methyl]-9-(3-aminopropyl)- 4H-carbazol-4-one (GR-H) was labeled with the fluorophores rhodamine 6G, fluorescein, N-[7-nitrobenz-2-oxa-1,3-diazol-4-yl], and the cyanine dye Cy5. These labels cover a large part of the visible electromagnetic spectrum. It is shown that the photophysical and chemical properties have a direct influence on the measurement quality (duration of measurement, signal-to-noise ratio) and the ligand-receptor interactions (dissociation constants), respectively. This makes it necessary to choose a suitable label or a combination of labels for receptor studies. The affinities of the fluorescently labeled ligands determined by FCS were virtually identical to the values obtained by radioligand binding experiments. Moreover, the dissociation constant of a nonfluorescent receptor ligand was determined successfully by an FCS competition assay. The experimental results showed that only one antagonist binds to the receptor, in agreement with measurements previously published [Tairi et al. (1998) Biochemistry 37, 15850-15864].

4-Chloro-7-nitrobenzofurazan↗

Resolution of fluorescence correlation measurements.

The resolution limit of fluorescence correlation spectroscopy for two-component solutions is investigated theoretically and experimentally. The autocorrelation function for two different particles in solution were computed, statistical noise was added, and the resulting curve was fitted with a least squares fit. These simulations show that the ability to distinguish between two different molecular species in solution depends strongly on the number of photons detected from each particle, their difference in size, and the concentration of each component in solution. To distinguish two components, their diffusion times must differ by at least a factor of 1.6 for comparable quantum yields and a high fluorescence signal. Experiments were conducted with Rhodamine 6G and Rhodamine-labeled bovine serum albumin. The experimental results support the simulations. In addition, they show that even with a high fluorescence signal but significantly different quantum yields, the diffusion times must differ by a factor much bigger than 1.6 to distinguish the two components. Depending on the quantum yields and the difference in size, there exists a concentration threshold for the less abundant component below which it is not possible to determine with statistical means alone that two particles are in solution.

Animals↗