PubMed Health⌕ Search

Biomedical subjects

T Y Kuo

Publications and source records attributed to T Y Kuo.

8 recordsLinked to original sources

Comparison of human, primate, and canine femora: implications for biomaterials testing in total hip replacement.

The canine model remains an animal of choice for determining the efficacy and safety of various materials and designs used in human total hip replacement (THR). The primate also is used in orthopedic-related research for studying limb anatomy, gait, and age-related bone loss. In order to better understand the appropriateness of these animal models for human THR, external morphologies of thirty-three adult Caucasian human, sixteen adult chimpanzee, and forty-two adult greyhound femora were compared using osteometric methods. Measured parameters included anteversion angle, cervico-diaphyseal angle, femoral head offset in the frontal plane, and anterior bow profiles along the femoral diaphysis. Although some of the measured parameters were approximately similar between species (e.g., mean cervico-diaphyseal angle of humans and chimpanzees), the majority demonstrated morphologic differences that may be biomechanically significant for interpreting stress transfer across the hip (e.g., mean anteversion angle and mean normalized femoral head offset between species). Additionally, age-related changes in proximal femoral morphology and gait pattern, as well as species-related differences in local muscle and inertial forces, may result in notably different loading conditions across the hip joint of each species. Therefore, discretion must be exercised when evaluating canine or primate THR materials and designs for potential use in the human hip.

Adolescent↗

Dosimetric measurements in the neutron field produced by a deuterium gas target with a compact medical cyclotron.

Several dosimetric measurements have been carried out in the neutron field produced by accelerated deuterons incident upon a pressurized deuterium gas target. A significant improvement has been achieved in central-axis depth dose when compared to the 9Be(3He,n)11C interaction previously studied . Designs for a target with a high-power dissipation capability are currently underway.

Deuterium↗

The influence of target thickness and backstop material on proton-produced neutron beams for radiotherapy.

Results are presented of measurements of skin sparing, penetration and total dose per unit of incident charge for various target thicknesses and filtrations for a neutron beam generated by 42 MeV protons on beryllium. These results are contrasted to predictions outlined in a previous paper. The differences from these predictions are attributed to the contribution of low-energy neutrons produced by the residual proton beam in the thick copper target backstop.

Activation Analysis↗

p(42)Be neutron therapy beams: dose rate and penetration as a function of target thickness and beam filtration.

It is shown that, in the production of p(42)Be neutron beams for clinical use, the use of semithick targets leads to more desirable beam characteristics when appropriate backstop materials are used. Furthermore, an algebraic representation of beam penetration and of dose per unit charge on target, including hardening by polyethylene filters, provides a method for target optimization.

Beryllium↗