Miniature vibrating flow blood pump using a cross-slider mechanism for external shunt catheter.

The prototype of the miniature vibrating flow pump (VFP) is developed for the external shunt catheter. The cross-slider mechanism is applied to vibrate the tube, which causes the pumping effect. This mechanism results in successful development of the miniature and lightweight VFP. By the use of the prototype VFP, the experiment of the basic pump performance is made in detail based on the authorized procedure in the research field of fluids engineering. The typical H-Q curve of VFP, which is the relationship between the pump head and the flow rate, can be obtained. This result suggests that the miniature VFP developed here can be expected to be used as the booster pump for the external shunt catheter in clinical applications.

Arteriovenous Shunt, Surgical↗

Fluctuations of Emax of the left ventricle: effect of atrial natriuretic polypeptide.

Recently the circadian rhythm of fluctuations in heart rate variability (HRV) has gained increasing attention, and the use of appropriate treatment corresponding to the circadian rhythm has become an important issue. However, the question has been raised as to whether the rhythm of fluctuation is only limited to HRV, and if a rhythm is also present in the contraction of the heart. The mathematical technique of electrical circuit simulation of the cardiovascular system was used to observe the Emax rhythm. In this study, the therapeutic effect of various drugs, including atrial natriuretic polypeptide (ANP), was confirmed. The effect of inotropic drugs including ANP on Emax was observed, and the results based on an old and a new method of determining Emax . were examined. Furthermore, the chaos analysis of Emax was also made. The time series of Emax showed an increased complexity due to the administration of ANP. In conclusion, it might be important to consider not only the fluctuation of HRV, but also an analysis of the fluctuation in the contraction of the heart.

Adrenergic beta-Antagonists↗

Automatic detection and classification of abnormalities for artificial hearts using a hierarchical self-organizing map.

A hierarchical self-organizing map (SOM) has been developed for automatic detection and classification of abnormalities for artificial hearts. The hierarchical SOM has been applied to the monitoring and analysis of an aortic pressure (AoP) signal measured from an adult goat equipped with a total artificial heart. The architecture of the network actually consists of 2 different SOMs. The first SOM clusters the AoP beat patterns in an unsupervised way. Afterward, the outputs of the first SOM combined with the original time-domain features of beat-to-beat data are fed to the second SOM for final classification. Each input vector of the second SOM is associated with a class vector. This class vector is assigned to every node in the second map as an output weight and learned according to Kohonen's learning rule. Some experimental results revealed that a certain abnormality caused by breakage of sensors could be identified and detected correctly and that the change in the state of the circulatory system could be recognized and predicted to some extent.

Animals↗

Recent progress on the vibrating flow pump as a totally implantable ventricular assist device.

This study describes the present state of progress in the development of the vibrating flow pump (VFP) ventricular assist system. We have proceeded with development aiming at a totally implantable ventricular assist system with smaller size and lighter weight appropriate for Asians like the Japanese by increasing the drive frequency. An actuator is important for the development of the miniature sized and lightweight artificial heart. We applied a linear motor for the mechanical part at first. The step motor was applied after that. This form may be best if we want the lightweight small sized motor for an actuator. The cross slider form is applied at present. It succeeded in the miniaturization compared with the linear motor. In the VFP-type ventricular assist system, the blood contact parts are a central vibration tube with inflow and outflow chambers. We designed round diaphragms to prevent thrombus formation. In addition, we developed an energy transmission system for total implantation. The VFP creates a high frequency oscillated blood flow. It has a unique flow pattern. Brain blood flow increased although the total flow of the circulation did not change in the frequency of 25 to 30 Hz. The quantitative evaluation of the autonomic nerve function during the left heart assistance with an oscillated blood flow was carried out by spectral analysis. Some influences on an autonomic nerve were observed by the VFP left heart assistance. We will continue development research with the aim of clinical application.

Animals↗

[Relationship between depression and lipid metabolism in the elderly with hypertension].

In order to examine the relationship between depressive symptoms and the lipid metabolism in the elderly with hypertension, we recruited 311 outpatients aged 65 or older with hypertension and defined depression as patients with 6 or more symptoms on Geriatric Depression Scale short form. We further classified depressed patients into three groups: mild depressed with 6-7 symptoms, moderate depressed with 8-10 symptoms and severe depressed with 11 or more symptoms. Serum total cholesterol, serum HDL cholesterol and serum LDL cholesterol levels were significantly higher in female depressed patients than those in nondepressed patients (TC, 194.6 +/- 30.1 vs 208.0 +/- 32.8 p < 0.01; HDL, 67.3 +/- 19.3 vs 72.3 +/- 16.2 p < 0.01; LDL, 107.6 +/- 26.5 vs 116.0 +/- 29.1 p < 0.05). In male patients, serum lipids were not significantly associated with depressive symptoms but depressed patients were significantly older than nondepressed patients (75.3 +/- 6.2 vs 78.0 +/- 5.9 p < 0.05). Concerning the analysis of the severity of depression, serum total cholesterol and serum LDL cholesterol levels were significantly higher in mildly depressed patients than nondepressed patients in females and the same tendency was seen in male patients. No linear associations were shown between the severity of depression and serum lipids. We concluded that hyperlipidemia may be associated with depressive symptoms in elder patients with hypertension and that it might be related the severity of depression. We need to further investigate the relationship between depression and lipid metabolism in larger population samples.

Aged↗

Evaluation of the inner-surface morphology of an artificial heart by acoustic microscopy.

The total artificial heart (TAH) is being developed for permanent replacement of the natural heart instead of heart transplantation. The need for detecting the material fatigue in the TAH is increasing in order to guarantee long-term use. In this study, the inner surface morphology of the TAH was evaluated by a specially developed scanning acoustic microscope (SAM) system operating in the frequency range of 100-200 MHz. The inner sac of our TAH consisted of polyvinylchloride coated with polyurethane, and the SAM investigations were performed before and after the implantations in goats. The amplitude images of the SAM demonstrated protein adhesion on the inner surface of the TAH after the animal experiment, and the phase images showed distortion of the wall with spatial resolution of 0.2 microm. These results suggest the feasibility of a high-frequency ultrasound for evaluating the material fatigue of TAH.

Animals↗

Totally implantable ventricular assist system that can increase brain blood flow.

In the clinical usage of the ventricular assist device (VAD), multiple organ failure becomes an important problem. To improve the clinical record of the VAD, another organ function may be vitally important. For that reason, we have been developing a VAD system aiming at improving another organ's function. Development of the vibrating flow pump (VFP), which can generate a very unique flow pattern from 10 Hz to 50 Hz, was ongoing in our Institute. In order to evaluate brain blood flow and oxygen consumption, HbO2 was measured with a NIRO monitoring device in healthy adult goats. Four goats were anesthetized with halothane inhalation; then left thoracotomy was performed for the left heart bypass. HbO2 of the brain was measured by recording of the hemodynamic variables during left heart assistance with the VFP system. During left heart bypass with the VFP system, hemodynamic parameters stayed within normal range, and satisfactory pump output was easily obtained. Pump output stayed within 20-40% bypass to evaluate the effect of high frequency oscillated assist flow on brain blood flow during the same cardiac output. Interesting results were observed during the experiments. During 30 Hz drive of the VFP left heart assistance, HbO2 suggested that brain blood flow significantly increased compared with another drive frequency assistance during the same total cardiac output. These results suggest that we can control the brain blood flow with a totally implantable VAD system such as the VFP system.

Animals↗

[Type A behaviour pattern and hypercholesterolemia in elder patients].

To examine the relationship between type A behavior pattern and hypercholesterolemia, we recruited 109 primary hypercholesterolemic patients without treatment for hyperlipidemia (30 males and 79 females) and then classified them according to Maeda's questionnaire into two groups; type A group (16 males and 35 females, aged 73.1 +/- 8.7) and type B group (14 males and 44 females, aged 71.3 +/- 8.7). We studied serum total cholesterol, serum triglyceride and BMI. Serum total cholesterol was shown significantly higher in type A group than that in type B (233.0 +/- 22.8 vs 223.9 +/- 14.2 p < 0.01) and BMI lower (24.0 +/- 3.9 vs 25.4 +/- 3.9 p < 0.05), however, there was no significant difference in serum triglyceride between two groups (148.96 +/- 8.2 vs 134.0 +/- 48.8). Although there was no significant difference in BMI, serum total cholesterol was significantly higher in the women's group and in the 60s. This study suggests that type A behavior pattern is related to lipid metabolism, however we should take gender and age into consideration to study the relationship between type A behavior pattern and lipid metabolism.

Aged↗

Chaotic dynamics in circulation with Tohoku University vibrating flow pump.

For the development of a totally implantable ventricular assist system (VAS), we have been developing the vibrating flow pump (VFP), which can generate oscillated blood flow with a relative high frequency (10-50 Hz) for a totally implantable system. In this study, the effects of left ventricular assistance with this unique oscillated blood flow were analyzed by the use of nonlinear mathematics for evaluation as the whole circulatory regulatory system, not as the decomposed parts of the system. Left heart bypasses using the VFP from the left atrium to the descending aorta were performed in chronic animal experiments using healthy adult goats. The ECG, arterial blood pressure, VFP pump flow, and the flow of the descending aorta were recorded in the data recorder during awake conditions and analyzed in a personal computer system through an A-D convertor. By the use of nonlinear mathematics, time series data were embedded into the phase space, the Lyapunov numerical method, fractal dimension analysis, and power spectrum analysis were performed to evaluate nonlinear dynamics. During left ventricular assistance with the VFP, Mayer wave fluctuations were decreased in the power spectrum, the fractal dimension of the hemodynamics was significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that nonlinear dynamics, which mediate the cardiovascular dynamics, may be affected during left ventricular (LV) bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. Decreased sympathetic discharges may be the origin of the decreased Mayer wave and fractal dimension. These nonlinear dynamic analyses may be useful to design optimal VAS control.

Analog-Digital Conversion↗

A future prediction type artificial heart system.

The demand of the biological system needs to be predicted to consider the quality of life (QOL) of a patient with an artificial heart system. The purpose of this study was the prediction of the imminent cardiac output and the predictive control for an artificial heart. For that purpose, autonomic nerve information was applied in this study. Nervous sympathicus action potentials were measured, and a prediction function of cardiac output was made using the sympathetic tone and preload and after-load measurement with multiple regression analysis. The predicted value showed significant correlation with the measured value after 2.9 s. Currently, however, long-term instrumentation of the nervous sympathicus potential is difficult. Thus, hemodynamic fluctuations, which recently have attracted attention, were used in this study. A prediction function using the Mayer wave, which represented nervous sympathicus, was determined. As a result, mid-term prediction became possible. Furthermore, a measurement of the vagal nerve was used as a possible long-term prediction parameter. For long-term prediction, Hurst exponent analysis was used in this study. Vagal nerve discharges in the changing position showed alteration of long-term determination. In conclusion, the future prediction control of an artificial heart takes shape using these prediction functions.

Action Potentials↗

Vagal nerve activity recording in the awake condition for the control of an artificial heart system.

To detect useful information for an artificial heart control system, we paid attention to the autonomic nervous system. For stable recording, we used vagal nerve activity in chronic animal experiments using healthy adult goats in an awake condition because this nerve was sufficiently bold and large enough. Vagal nerve discharges were successfully recorded from awake goats. They were synchronized with respiration and responded to the hemodynamic changes induced by drug administration, suggesting that they may provide useful information for an artificial heart control algorithm. For automatic control, some time delay plays a vitally important role. Thus, predictive control for an artificial heart system may be desirable. It may be embodied by the use of autonomic nerve information.

Action Potentials↗

Total vascular resistance and blood flow frequency during left ventricular assistance using a vibrating flow pump.

A vibrating flow pump (VFP) can generate high frequency oscillated blood flow within 10-30 Hz by the oscillation of its central tube. A totally implantable artificial heart using a VFP is being developed as a unique type of blood pump. In this study, left ventricular (LV) assist circulation was performed using a VFP. The total vascular resistance and driving frequency of the VFP were estimated from their relationship. The effect of oscillation on the vascular system was studied by the frequency analysis method and vascular impedance. Adult goats were anesthetized by halothane using an inhaler and a left fourth thoracotomy was performed. The inflow cannula was inserted into the left ventricle, and the outflow cannula was sutured to the descending aorta. The VFP and a centrifugal pump were set in parallel for alternation and comparison. The driving frequency of the VFP was changed and included 15, 20, 25, and 30 Hz. The hemodynamic parameters were continuously recorded during experiments by a digital audio tape (DAT) data recorder. The internal pressure of the left ventricular cavity and aortic pressure were monitored by the pressure manometers continuously. One hundred percent LV assistance was judged by the separation of LV and aortic pressure. The total vascular resistance was decreased by the start of operation of each pump. The decrease during flow using the VFP was not as large as that using a centrifugal pump (CP). The arterial input impedance during oscillated blood flow by the VFP showed a slow curve appearance. It was similar to the frequency characteristics curve of natural heart beats within the lower frequencies. The study of arterial impedance may be important for the estimation of the reflection of the pulsatile wave from the arterial branch, among other things.

Animals↗

Peripheral vascular resistances during total left heart bypass with an oscillated blood flow.

For development aimed at a totally implantable type ventricular assist device (VAD), the vibrating flow pump (VFP) has been developed at Tohoku University. A transcutaneous energy transmission system (TETS) using amorphous fibers was developed to power the totally implantable VAD system. The VFP works at a high frequency compared to that of a natural heart of a biological system. It is a frequency of 10-50 Hz. In this research, animal experiments with left heart bypass were carried out with healthy adult goats. For comparison between nonpulsatile flow and oscillated flow, a rotary pump (RP) and the VFP were used in the experiments. For the achievement of total left heart bypass, left ventricular approaches were carried out, and blood was pumped from the left ventricle to the descending aorta. Adequate support of the left heart was provided by both pumps. In terms of the results, the vascular resistances tended to decrease during the use of both pumps during 100% bypass driving. When we compared these pumps at the same flow rate, the resistances during RP driving were significantly smaller than those during VFP driving. These results may suggest that the influences of the VFP upon the peripheral vessels may be relatively small compared to those of the RP. This may be an important result when a stable hemodynamic condition is required during artificial circulation. The VFP was considered as a candidate for a totally implantable VAD as a result.

Animals↗

Detection of the cardiac function by fractal dimension analysis.

Nonlinearity in circulation control attracts attention because nonlinearity is thought to be essential in the function of the living body. Many investigators have pointed out that the analysis of heart rate variability in particular is important in the analysis of autonomic nerve and cardiac function evaluation. Heart rate variability shows nonlinear behavior. However, until the present, many reports have been premised on linearity; linear correlation by frequency analysis has been used by many studies. However, in terms of this methodology, there is a problem applying it to the nonlinear living body. Therefore, fractal and chaos methodology has been used. The ascertainment of cardiac function has become important in allowing the clinical stage of a ventricular assist system to be successful. The purpose of this study was cardiac function evaluation by a methodology that was premised on nonlinearity. Chaos and fractal theory was used as a nonlinear dynamic theory. As a methodology of measurement, the volume of the left ventricle was used rather than an electrocardiogram, the waveform of arterial blood pressure. The volume was measured using acoustic quantification (AQ) ultrasonic echocardiography. Using these methodologies, the time series of many patients were analyzed. For example, drug administration was attempted in this study, and it was found that some drugs like ACE inhibitors showed a significant effect upon nonlinear dynamics in the cardiovascular system. The result, which attempted cardiac function evaluation by these various methodologies, is reported.

Angiotensin-Converting Enzyme Inhibitors↗

Vagal nerve activity and the high frequency peak of the heart rate variability.

For the Quality of life (QOL) of patients with an artificial heart system, monitoring an information of the cardiovascular control system may be important. We have been evaluating the autonomic nervous system for that purpose. Recently, fluctuations in hemodynamic parameters including heart rate variability (HRV) were evaluated by means of spectral analysis and nonlinear mathematical analysis. Respiratory wavers in HRV were thought to reflect ongoing information of the parasympathetic nerve activity. Is it true? In order to confirm this hypothesis, we recorded vagal nerve activity directly in the chronic animal experiments. Six healthy adult goats were anesthetized with Halothene inhalation and thoracotomy were performed by the fourth lib resection during mechanical ventilation. Arterial blood pressure, right and left atrial pressures were continuously monitored with the catheter insertion. Cardiac output was measured by the electromagnetic flowmeter attached to the ascending aorta. After the chest was closed, incision was made to the left neck and left vagal nerve was separated. Stainless steel electrodes were inserted into the vagal nerve and fixed by the plasticizer. After the incision was closed, the goats were transferred to the cage and extubated after waking. Hemodynamic parameters and vagal nerve activity were measured in the awake condition. The results showed that clear observation of the autonomic nerve discharges were embodied by this experimental system. The vagal nerve discharges were synchronized with heart beat and respiration. The vagal nerve tonus was significantly influenced by the hemodynamic alteration. However in some condition, the respiratory wave was not always consistent with tonus of the vagal nerve activity, thus suggesting that we should check another information to evaluate the parasympathetic tone. We must continue this study to evaluate an autonomic nerve during artificial heart circulation.

Animals↗

Virtual percutaneous transluminal coronary angioplasty system for an educational support system.

With the increase of ischemic diseases of the circulatory system in Japan, the necessity for cardiovascular intervention continues to increase. However, because intervention operations have been developed only recently, the education system for the corresponding specialists in our country has not been established yet. In this study, an intervention educational support system using a virtual reality (VR) technique was developed. Of course, intervention includes percutaneous transluminal coronary angioplasty (PTCA). PTCA is an operation enlarging the stenosis of the coronary artery with a balloon through a guide catheter. The technique that lets the guide wire for the PTCA balloon cross the stenosis is one of the most difficult. A simulation system for the manipulation of a torque device for the PTCA guide wire was developed with this technology for VR. In virtual space, reconstitution of the 3-dimensional coronary artery with atherosclerosis was performed, and the virtual PTCA system was produced experimentally. An interesting system was produced experimentally as a system for the training of doctors studying to become interventional specialists. After the system was combined with an Expert system for treating ischemic heart diseases, its usefulness was steadily increased. With the development of more sophisticated VR methodology in the future, a PTCA training system without using a patient will be embodied.

Angioplasty, Balloon, Coronary↗

Left heart bypass using the oscillated blood flow with totally implantable vibrating flow pump.

Aiming at a totally implantable ventricular assist device (VAD), a vibrating flow pump (VFP) was developed in Tohoku University. A transcutaneous energy transmission system (TETS) using an amorphous fiber was developed for the totally implantable VAD system. The VFP works with a higher frequency than the natural heart of a biological system, a frequency of 10-50 Hz. In this research, animal experiments on left heart bypass were performed with healthy goats. Blood from the apex of the left ventricle was received and was sent to the aorta so that an adequate supporting effect of the left heart was provided. In particular, the depression effect of the left ventricle was obvious. As a result, sufficient artificial heart flow was provided. For a totally implantable type VAD, left heart bypass of almost 100% may become necessary in some situations. Therefore, apex approaches of left heart bypass may be desirable. From an anatomical consideration, an apex of the heart is suitable for the VFP of this totally implantable type. In the left heart bypass for which the apex of the heart was used, an almost 100% bypass was possible. This is a requirement that is important when waiting for recovery of sufficient cardiac function. It is also important that left heart circulation is maintained fully by an artificial heart of the complete implantation type. The VFP was considered to be useful as a totally implantable type artificial heart from the results.

Animals↗