PubMed HealthSearch

Biomedical subjects

TE Skinner

Publications and source records attributed to TE Skinner.

4 recordsLinked to original sources

A vector model of adiabatic decoupling

A vector model of adiabatic decoupling is enunciated for an IS-coupled system of two spin-(1/2) heteronuclei in the high-power limit of ideal adiabatic pulses. The observed S-spin magnetization evolves according to a time-dependent coupling that scales as the z component of an I-spin vector which evolves due to the applied decoupling irradiation. Simple analytical expressions are derived both on and off resonance for the reduced coupling during an ideal sech/tanh inversion pulse and for the resulting signal when either in-phase or antiphase magnetization is present at the start of decoupling. The resulting model allows one to readily envision decoupling experiments, make accurate estimates of sideband intensity, and assess the relative performance of different decoupling schemes. The utility of the model is further demonstrated by applying it to several recently proposed methods for reducing sidebands. In the limit of ideal adiabatic pulses, the predictions of the vector model are almost identical to those of quantum mechanics. At the lower RF power levels used in practical adiabatic decoupling applications, where the pulses are no longer perfectly adiabatic, phase cycles are employed to achieve performance that approximates the ideal limits derived here, so the vector model is more generally applicable, as well. These limits establish standards for future determination of the most efficient parameters for practical applications of broadband adiabatic decoupling in a single transient. Copyright 1998 Academic Press.

Journal Article

Calibration of STUD+ parameters to achieve optimally efficient broadband adiabatic decoupling in a single transient

To provide the most efficient conditions for spin decoupling with least RF power, master calibration curves are provided for the maximum centerband amplitude, and the minimum amplitude for the largest cycling sideband, resulting from STUD+ adiabatic decoupling applied during a single free induction decay. The principal curve is defined as a function of the four most critical experimental input parameters: the maximum amplitude of the RF field, RFmax, the length of the sech/tanh pulse, Tp, the extent of the frequency sweep, bwdth, and the coupling constant, Jo. Less critical parameters, the effective (or actual) decoupled bandwidth, bweff, and the sech/tanh truncation factor, beta, which become more important as bwdth is decreased, are calibrated in separate curves. The relative importance of nine additional factors in determining optimal decoupling performance in a single transient are considered. Specific parameters for efficient adiabatic decoupling can be determined via a set of four equations which will be most useful for 13C decoupling, covering the range of one-bond 13C1H coupling constants from 125 to 225 Hz, and decoupled bandwidths of 7 to 100 kHz, with a bandwidth of 100 kHz being the requirement for a 2 GHz spectrometer. The four equations are derived from a recent vector model of adiabatic decoupling, and experiment, supported by computer simulations. The vector model predicts an inverse linear relation between the centerband and maximum sideband amplitudes, and it predicts a simple parabolic relationship between maximum sideband amplitude and the product JoTp. The ratio bwdth/(RFmax)2 can be viewed as a characteristic time scale, tauc, affecting sideband levels, with tauc approximately Tp giving the most efficient STUD+ decoupling, as suggested by the adiabatic condition. Functional relationships between bwdth and less critical parameters, bweff and beta, for efficient decoupling can be derived from Bloch-equation calculations of the inversion profile for a single sech/tanh pulse. Residual splitting of the centerband, normally associated with incomplete or inefficient decoupling, is not seen in sech/tanh decoupling and therefore cannot be used as a measure of adiabatic decoupling efficiency. The calibrated experimental performance levels achieved in this study are within 20% of theoretical performance levels derived previously for ideal sech/tanh decoupling at high power, indicating a small scope for further improvement at practical RF power levels. The optimization procedures employed here will be generally applicable to any good combination of adiabatic inversion pulse and phase cycle. Copyright 1998 Academic Press.

Journal Article

Coherence sidebands in adiabatic decoupling

RF pulse sequences applied to IS spin systems may produce substantial transverse antiphase S magnetization coupled to antiphase I magnetization, just prior to detection of the S signal, for samples containing a range of J coupling constants, or when pulse sequence delays are misset from ideal values. This magnetization is generally considered to be unobservable. Adiabatic decoupling on the I spins during signal detection efficiently converts this magnetization to observable S signal in the form of sidebands which we dub "coherence sidebands." Three single-transient pulsed-field-gradient methods are described for eliminating these unwanted sidebands. The techniques are applicable to 1H-detected 13C-decoupled experiments on spectrometers operating at a 1H frequency of up to 2 GHz. Copyright 1997 Academic Press. Copyright 1997Academic Press

Journal Article