[Image quality and detection performance of a direct digital radiography system].

The physical characteristics of a direct amorphous Selenium (a-Se) digital fluoroscopy and radiography system were investigated. Pre-sampled modulation transfer functions (MTF) were measured using a slit method. Noise power spectra were determined for different input exposures by fast Fourier transform of uniformly exposed samples. The MTFs of direct digital radiography systems showed significantly higher values than those of indirect digital radiography and screen-film systems. The direct digital radiography systems showed higher noise levels compared with those of indirect systems under roughly the same exposure conditions. Contrast-detail analysis was performed to compare detection by direct digital radiography systems with that of the screen-film (FUJI HG-M2/UR2) systems. The average contrast-detail curves of digital and film images were obtained from the results of observation. Image quality figures (IQF) were also calculated from the individual observer performance tests. The results indicated that digital contrast-detail curves and IQF are, on average, are equal those of the screen-film system.

Fourier Analysis↗

Physical imaging properties and low-contrast performance of a newly developed flat-panel digital radiographic system.

We investigated the clinical usefulness of a newly developed flat-panel detector (FPD) system by comparing its physical imaging properties and low-contrast detectability with those of a current FPD system. The newly developed CsI-based indirect FPD (Canon, CXDI-40C) and current Gd(2)O(2)S-based FPD (Canon CXDI-11) systems were used. Characteristic curves, resolution properties, radiographic noise, detective quantum efficiencies (DQEs) and low-contrast detectability for both systems were measured. The new FPD system showed considerably lower noise levels than those of the current FPD system. DQE (0) s of the new and current FPD systems were 75% and 35%, respectively. Observer performance tests of the contrast-detail (C-D) phantom indicated that the new FPD system can significantly improve low-contrast performance over that obtainable with the current FPD system under the same conditions of exposure. The new FPD system provided approximately 50% reduction in exposure while providing comparable detectability. The newly developed FPD system provides radiographic images with excellent inherent physical image quality and low-contrast performance.

Cesium↗

[CR-mammography with pixel size of 50 microm and dual-sided reading system: effect of the oblique incident of the X-ray beam on imaging properties and detection].

In mammography units, the X-ray tube focal spot is located directly above the chest wall edge of the detector. Therefore, the X-ray beam is incident at a different angle along the cathode-anode axis. When the X-ray beam is incident on the imaging plate (IP) at a relatively large angle, the resolution property of a new imaging plate with dual-sided reading system would be degraded compared with the conventional imaging plate because of the parallax effect, which produces a shift in the image on two sides of the imaging plate. To evaluate the oblique incidence effect of the X-ray beam on the degradation of resolution properties and detection of simulated microcalcifications of a new CR system with a pixel size of 50 microm, its basic imaging properties and observer performance tests were compared with those of a conventional CR system. The resolution properties were evaluated by measuring modulation transfer functions (MTFs). Observer performance tests were conducted to compare the detectability of simulated microcalcifications of CR systems. Degradation of presampling MTFs for the new system is greater than that of the conventional CR system when the X-ray beam was incident at the same angle on the imaging plate. We found that the degradation of the area under the ROC curve (Az) for the new CR system was greater than that of the conventional CR system when the X-ray beam was incident at the same angle on the imaging plate.

Calcinosis↗

[Full-field digital mammography with amorphous silicon-based flat- panel detector: physical imaging characteristics and signal detection].

The physical characteristics of a clinical amorphous silicon-based flat-panel imager for full-field digital mammography were investigated. Pre-sampled modulation transfer functions (MTF) were measured by using a slit method. Noise power spectra were determined for different input exposures by fast Fourier transform. The MTFs of full-field digital mammography systems showed significantly higher values than those of the computed radiography (CR) system. The full-field digital mammography system showed a lower noise level than that of the CR system under the same exposure conditions. Contrast detail analysis has been performed to compare the detectability of the full-field digital mammography system with that of the screen-film (Min-R 2000/Min-R 2000) system. The average contrast-detail curves of digital and film images were obtained from the results of observation. Image quality figures (IQF) were also calculated from the individual observer performance tests. The results indicated that the digital contrast-detail curves and IQF, on average, are superior to those of the screen-film system.

Fourier Analysis↗

[ROC analysis of detection of interval changes in interstitial lung diseases on digital chest radiographs using the temporal subtraction technique].

PURPOSE: To demonstrate the clinical usefulness of a temporal subtraction technique for the detection of interval changes in various interstitial lung diseases on digital chest radiographs. MATERIALS AND METHODS: One hundred pairs of chest radiographs in 34 patients (63 with and 37 without interval changes) with various interstitial lung diseases were selected. All cases were confirmed by serial chest computed tomography (CT) and ascertained by radiologists. All chest radiographs were obtained with a computed radiography (CR) system, and temporal subtraction images were produced with an iterative image-warping technique. Four radiologists and two thoracic physicians provided confidence levels for interval changes in interstitial lung diseases with and without temporal subtraction. Their performances with and without temporal subtraction were evaluated by means of receiver operating characteristic (ROC) analysis using a sequential test. RESULTS: The area under the ROC curve (Az) values of six observers obtained with and without temporal subtraction were 0.90 and 0.78, respectively. Results showed that the detection of interval changes in interstitial lung diseases was significantly improved by the use of temporal subtraction images compared with CR images alone(P = 0.002). Furthermore, the high detection rate was achieved with temporal subtraction images regardless of the subtlety and location of interval changes. CONCLUSION: Temporal subtraction improved the diagnostic accuracy of radiologists in detecting interval changes in interstitial lung diseases on chest radiographs. It was also useful for cases of multiple interval changes.

Adult↗

[Usefulness of the opposite direction for Stenvers' method].

In otorthinolaryngology, Stenvers' method is employed in radiography of the pyramid (internal acoustic meatus and semicircular canals). However, in cases of dizziness, where the prone position is difficult to achieve, we occasionally use the opposite Stenvers' method instead of the conventional one. This makes it possible to perform radiography with the patient in the supine position. Compared with the conventional Stenvers' method, the problems of this method were increases not only in the rate of magnification but also in lens dose. In this study, we evaluated these problems by employing computed tomography (CT) and a glass dosimeter with phantom as well as by clinical evaluation. The results showed no statistically significant difference between Stenvers' method and the opposite Stenvers' method in both the rate of magnification and the clinical evaluation. The increase in lens dose with the opposite Stenvers' method was not significant. We concluded that the opposite Stenvers' method was useful.

Adult↗

[Canon's flat-panel detector].

We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ) ) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm(-1), but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of FPD system were better than those of FCR system a little at lower spatial frequencies than 1.6 mm(-1), but the overall NEQ of FPD and FCR systems were worse than that of S/F system at all spatial frequencies. Comparison of chest phantom images showed that the FPD produced images with quality comparable to or higher than those of the FCR system. From these results, we can expect that the FPD is useful machine by using digital image processing and so on in the radiology department.

Image Processing, Computer-Assisted↗

New CR system with pixel size of 50 microm for digital mammography: physical imaging properties and detection of subtle microcalcifications.

PURPOSE: To investigate the physical imaging properties and detection of simulated microcalcifications of a new computed radiography (CR) system with a pixel size of 50 microm for digital mammography. MATERIALS AND METHODS: New and conventional CR were employed in this study. The new CR system included a high-resolution imaging plate coupled with the FCR5000MA (50 microm pixel pitch) including transparent support and a dual-sided reader. The conventional CR system was coupled with the FCR9000 (100 microm pixel pitch). Modulation transfer functions (MTFs) and Wiener spectra (WS) of the new and conventional CR systems were measured. Observer performance tests were conducted to compare the effects of pixel size (50 microm vs. 100 microm) on the diagnostic accuracy of CR systems in the detection of simulated microcalcifications. RESULTS: The presampling MTF of the new CR system was higher at high frequencies than the conventional CR system. The WS of the new CR system was comparable to that of the conventional CR system at all frequencies. The area under the receiver operating characteristic (ROC) curve (Az) obtained with the new CR and the conventional CR systems were 0.84 and 0.79, respectively. Results showed that the detection of simulated clustered microcalcifications was significantly improved by use of the new CR system compared with the conventional CR system (p<0.05). CONCLUSION: The new CR mammography system improved physical imaging properties and detection of simulated microcalcifications over conventional CR mammography.

Animals↗