PubMed Health⌕ Search

Biomedical subjects

Tadeusz Stepinski

Publications and source records attributed to Tadeusz Stepinski.

2 recordsLinked to original sources

Synthetic aperture imaging using sources with finite aperture: deconvolution of the spatial impulse response.

A method for ultrasonic synthetic aperture imaging using finite-sized transducers is introduced that is based on a compact, linear, discrete model of the ultrasonic measurement system developed using matrix formalism. Using this model a time-domain algorithm for deconvolution of the transducer's spatial impulse responses (SIRs) is developed that is based on a minimum mean square error (MMSE) criterion. The algorithm takes the form of a spatiotemporal filter that compensates for the SIRs associated with a finite-sized transducer at every point of the processed image. A major advantage of the proposed method is that it can be used for any transducer, provided that its associated SIRs are known. This is in contrast to the synthetic aperture focusing technique (SAFT), which treats the transducer as a point source. The performance of the method is evaluated with simulations and experiments, performed in water using a linear phased array. The results obtained using the proposed method are compared to those obtained with a classical time-domain SAFT algorithm. For a finite aperture source, it is clearly shown that the resolution obtained using the proposed method is superior to that obtained using the SAFT algorithm.

Journal Article↗

A spatial impulse response based method for determining effective geometrical parameters for spherically focused transducers.

This paper proposes a novel method for determining effective geometrical parameters (GPs) of spherically focused transducer. Theoretical basis of the method is the spatial impulse response method (SIRM) that is a powerful tool to calculate transient fields from a piston-like transducer. Experimentally, the method is implemented by measuring arrival times of the pulse signals (either transmission or pulse echo signals) and using them to determine the time intervals between the direct and edge wave pulses. Since the time intervals for a given measurement position depend on the transducer's GPs, then the effective GPs can be obtained. The measurements are carried out in the near-field so that the time intervals can be resolved. The proposed method has been applied to a spherically focused transducer operating in pulse echo mode. The results have shown that the effective GPs used in the SIRM give a closer agreement between the theory and the measurements than the nominal GPs. The method is best suited for characterizing broadband transducers with short pulse excitations. With certain modification it can be also applied to narrowband transducers. The method can be also applied to transducers of other shapes, e.g., planar circle, and planar or curved rectangle provided the piston approximation is appropriate.

Journal Article↗