[Development of three-dimensional kinematic analysis system for artificial knee implants using X-ray fluoroscopic imaging].

To achieve quantitative assessment of 3D dynamic motion of artificial knee implants under clinical conditions, we developed a 3D kinematic analysis system using X-ray fluoroscopic imaging. The 3D pose-estimation technique for knee implants was built on a 2D/3D registration algorithm, which determines the spatial pose for each femoral and tibial component from the knee implant contours and computer-assisted design (CAD) models of the implant. In order to validate the accuracy of the 3D pose estimation and the system, computer simulation and in vitro tests were performed using images of knee implants taken in 10 different poses with respect to X-ray focus. Computer simulation tests showed that the root mean square errors (RMSE) for all variables were less than 1.0 mm 1.0 degrees. In vitro tests showed that the RMSE for translation perpendicular to the X-ray image plane was about 1.5 mm, while the accuracy of the remaining two translational and three rotational variables was found to be sufficient for analyzing knee kinematics. Computation time in 3D pose estimation was then obtained in less than 30 seconds for each frame. In clinical application, dynamic movement in deep knee bending was quantitatively analyzed, and the feasibility and effectiveness of the system was demonstrated.

Algorithms↗

Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy.

The purpose of this study was to build a visualization technique of the femorotibial contact in fixed-bearing total knee arthroplasty (TKA) using X-ray fluoroscopy, and to apply this technique to a TKA patient during dynamic motion. In vivo kinametcis of the metallic knee implant was determined using a 2D/3D registration technique, which uses computer assisted design (CAD) model of the implant to estimate the 3D pose of radiopaque metallic femoral and tibial components from a single-plane fluoroscopic image. In fixed-bearing TKA, a 3D pose of radiolucent tibial polyethylene insert can be determined from the estimated pose of the tibial component. To visualize femorotibial contact, the proximity between surfaces of femoral component and tibial insert was calculated, and mapped onto the insert surface model. For the clinical application, dynamic states of contact on the tibial insert were observed including axial rotation and unilateral loading during knee flexion, and post-cam contact of posterior stabilized TKA. The present technique provided us new information and enabled us to better understand the relationship between in vivo knee kinematics and articular shape of the implant.

Arthroplasty, Replacement, Knee↗

In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion.

The current study aimed to analyze kinematics during deep knee bending motion by subjects with fully congruent mobile-bearing total knee arthroplasties allowing axial rotation and anteroposterior (AP) gliding. Twelve subjects were implanted with Dual Bearing Knee prostheses (DBK, slot type: Finsbury Orthopaedics, Surrey, UK). These implants include a mobile-bearing insert that is fully congruent with the femoral component throughout flexion and allows axial rotation and limited AP translation. Sequential fluoroscopic images were taken in the sagittal plane during loaded knee bending motion. In vivo kinematics were analyzed using a two- to three-dimensional registration technique, which uses computer-assisted design models to reproduce the spatial position of femoral and tibial components from single-view fluoroscopic images. The average femoral component demonstrated 13.4 degrees external axial rotation for 0-120 degrees flexion. On average, the medial condyle moved anteriorly 6.2 mm for 0-100 degrees flexion, then posteriorly 4.0 mm for 100-120 degrees flexion. On average, the lateral condyle moved anteriorly 1.0 mm for 0-40 degrees flexion, then posteriorly 8.7 mm for 40-120 degrees flexion. The typical subject exhibited a lateral pivot pattern from extension to 60 degrees flexion and a central pivot pattern from 60 degrees to 100 degrees flexion, patterns that are not usually observed in normal knees. Subsequently from 100 degrees to 120 degrees flexion, a rollback pattern was reproduced in which bilateral condyles moved backward.

Aged↗

Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy.

Two-dimensional (2-D)/three-dimensional (3-D) registration techniques using single-plane fluoroscopy are highly important for analyzing 3-D kinematics in applications such as total knee arthroplasty (TKA) implants. The accuracy of single-plane fluoroscopy-based techniques in the determination of translation perpendicular to the image plane (depth position), however, is relatively poor because a change in the depth position causes only small changes in the 2-D silhouette. Accuracies achieved in depth position using conventional 2-D/3-D registration techniques are insufficient for clinical applications. Therefore, we propose a technique for improving the accuracy of depth position determination in order to develop a system for analyzing knee kinematics over the full six degrees of freedom (6 DOF) using single-plane fluoroscopy. In preliminary experiments, the behaviors of errors for each free variable were quantified as evaluation curves by examining changes in cost function with variations in the free variable. The evaluation curve for depth position was more jagged, and the curve peak less pointy, compared to the evaluation curves of the other five variables, and the curve was found to behave differently. Depth position is therefore optimized independently of the other variables, using an approximate evaluation curve of depth position prepared after initial registration. Accuracy of the proposed technique was evaluated by computer simulation and in vitro tests, with validation of absolute position and orientation performed for each knee component. In computer simulation tests, root-mean-square error (RMSE) in depth position was improved from 2.6 mm (conventional) to 0.9 mm (proposed), whereas for in vitro tests, RMSE improved from 3.2 mm to 1.4 mm. Accuracy of the estimation of the remaining two translational and three rotational variables was found to be almost the same as that obtained by conventional techniques. Results of in vivo tests are also described in which the possibility of full 6 DOF kinematic analysis of TKA implants is shown.

Algorithms↗

In vivo elbow biomechanical analysis during flexion: three-dimensional motion analysis using magnetic resonance imaging.

The purpose of this article is to evaluate in vivo 3-dimensional kinematics of the elbow joint during elbow flexion. We studied the ulnohumeral and radiohumeral joint noninvasively in 3 elbows in healthy volunteers using a markerless bone registration algorithm. Magnetic resonance images were acquired in 6 positions of elbow flexion. The inferred contact areas on the ulna against the trochlea tended to occur only on the medial facet of the trochlear notch in all of the elbow positions we tested. The inferred contact areas on the radial head against the capitellum occurred on the central depression of the radial head in all of the tested elbow positions except for 135 degrees flexion, where the anterior rim of the radial head articulates with the capitellum.

Adult↗