PubMed Health⌕ Search

Biomedical subjects

Takashi Anazawa

Publications and source records attributed to Takashi Anazawa.

5 recordsLinked to original sources

Improvement of biomolecule quantification precision and use of a single-element aspheric objective lens in fluorescence correlation spectroscopy.

We found a way to increase the precision with which biomolecules present at concentrations below 10(-10) M can be quantified by fluorescence correlation spectroscopy (FCS). The effectiveness of the way was demonstrated experimentally by using a single-element aspheric objective lens, which was newly developed to reduce the cost of FCS instruments. In the first part of this paper, the relative standard deviation (RSD) of FCS-based concentration measurements is estimated theoretically by an analytical approximation assuming the detection volume profiles in FCS setups to be Gaussian and by molecular simulations in which more realistic profiles are calculated from physical parameters of the measurement setups. In a limit of infinitely bright molecules and zero background emission, the analytical approximation predicts that the RSD at a concentration is minimized when the mean number of molecules in a detection volume is approximately 0.5. A detection volume of the order of 10(-13) L thus gives smaller RSD values for concentrations from 10(-11) to 10(-10) M than does one of the order of 10(-15) L, which is widely used in FCS. This prediction is supported by the molecular simulations, taking into account the finite molecule brightness and background emission. In the second part of the paper, the RSD is evaluated experimentally with an FCS setup with a detection volume of 1.1 x 10(-13) L. The newly developed objective lens, serving as the bottom of the sample cell in this setup, has a large numerical aperture (0.9) without using immersion liquid. When a calibration line was made by 30-s FCS measurements of Cy3-labeled, 112-mer single-stranded DNA solutions, the RSD roughly agreed with the simulation result and was less than 0.1 for DNA concentrations from 2 x 10(-11) to 10(-10) M.

Algorithms↗

Ultra-slim laminated capillary array for high-speed DNA separation.

We developed a new kind of capillary array for electrophoresis by using the numerical-control (NC) wiring technique conventionally used to produce printed-circuit boards. Laminating two polyimide sheets after laying cylindrical capillaries between them according to designed geometries, we fabricated a 16-lane laminated capillary array (LCA) 9.9 cm long, 7.2 cm wide, and 0.5 mm thick in which the effective length of all capillaries was only 10.9 cm. This compact LCA thus had separation columns as short as those in capillary array electrophoresis chips fabricated by lithography techniques. Like conventional capillary arrays, it also enabled pipetting-less direct injection of analytes from sample preparation plates. Using the LCA with LIF detection and a replaceable fluid sieving matrix, we demonstrated high-speed ssDNA fragment separations. At an electric field strength of 316 V/cm, 15 fragments ranging from 50 to 500 bases were completely separated within 5.8 min in all lanes. The lane-to-lane CV of migration time was only 0.38%, and the fragment size for which the resolution per base was 0.59 was 258 +/- 15 bases (average +/-SD).

DNA, Single-Stranded↗

High-speed DNA sequencing by tube-based capillary electrophoresis.

We assessed the feasibility of high-speed DNA sequencing by tube-based capillary electrophoresis (TCE) with electrokinetic sample injections. We developed a water-circulated TCE system to control the capillary temperature precisely. Using this system and a ready-made sieving matrix at 50 degrees C, single-stranded DNA size marker fragments were separated at various pairs of the electric field strength, E, of 128-480 V/cm and the capillary effective length, L, of 100-360 mm. Assuming the read length (RL) is the fragment size at which the peak width equals the peak interval per base in obtained electropherograms, we estimated the values of RL (E, L), the RL at the pair (E, L). The points in ELz-space, (E, L, RL(E, L)), form a curved surface expressed by z = RL(E, L). Analyzing the contour lines of this curved surface, we determined the pairs of E and L providing target RLs of 300-500 bases within a minimum time. At a pair optimized for a 500-base RL (330 V/cm, 200 mm), one-color sequencing fragments were successfully separated up to 529 bases within 9.6 min. These results demonstrate that high-speed DNA sequencing comparable with that obtained by microfabricated chip-based capillary electrophoresis (MCE) can be achieved with TCE, which is more suitable in automation than MCE.

Electrophoresis, Capillary↗

Integrated on-capillary instrumentation for gene expression measurement directly from cells.

We studied the fundamental instrumental issues relevant to a capillary-based integrated system to measure expression of a specific gene directly from cells. Samples were introduced into a capillary by use of a syringe pump. All reactions were carried out in a microthermocycler, where a part of the capillary having 1 microL inner volume was used as a reaction vessel. First, cells were lysed by heating to release RNA, followed by deoxyribonuclease (DNase) treatment. Then, reverse transcription-polymerase chain reaction (RT-PCR) was performed to obtain amplified products from the targeted mRNA. Finally, the product was verified by capillary electrophoresis (CE) with laser-induced fluorescence detection. The whole protocol was completed in the system in 3 h. PCR product from beta-actin mRNA in 16 human lymphoblast cells was obtained with a signal-to-noise ratio (S/N) of 3400 +/- 730 (n = 3). Therefore, the system is reproducible and sensitive enough to measure gene expression from a single cell. We show that the amplified fragment from breast cancer-specific mRNA was obtained from cells of breast cancer cell line, but was not obtained from cells of hepatoma cell line. These results therefore lay the foundations for future CE or microchip instrumentation for high-throughput automated gene-expression analysis.

Actins↗

Electrophoretic quantitation of nucleic acids without amplification by single-molecule imaging.

We have developed a novel high-performance quantitative assay for unamplified nucleic acids that is based on single-molecule imaging. The apparatus is a simple but highly sensitive single-molecule detection system that uses a normal CCD camera instead of an image-intensified CCD camera. After the DNA molecules in a sample were labeled with YOYO-1, they were induced to migrate electrophoretically in a polymer solution and imaged. No chemical or biochemical amplification was required. Direct quantitation of the sample by counting molecules was possible, because the number counted over the measurement period was directly proportional to the concentration of DNA molecules in the sample. Nonspecifically labeled impurities that would degrade the sensitivity of the assay were successfully reduced and discriminated from the DNA molecules by differences in electrophoretic mobility. By using beta-actin DNA (838 bp) as a model sample, we demonstrate that this protocol was fast (10-min measurement period), highly sensitive (limit of quantitation: approximately 10(3) copies/sample, or 3 x 10(-16) M), quantitative, and covered a wide linear dynamic range (approximately 10(4)). This high-performance assay promises to be a powerful technology for the quantitation of specific varieties of mRNA in the study of gene functions and diseases and in the clinical detection of mutant cells.

Actins↗