PubMed Health⌕ Search

Biomedical subjects

Takehiro Miyasaka

Publications and source records attributed to Takehiro Miyasaka.

9 recordsLinked to original sources

Heart slice NMR.

Nuclear magnetic resonance (NMR) spectroscopy of the heart is normally carried out using whole heart preparations under coronary perfusion. In such preparations, either radical changes in ionic composition of the perfusate or applications of numerous drugs would affect coronary microcirculation. This report communicates the first (31)P NMR spectroscopy study using a heart slice preparation (left ventricular slices) superfused with extracellular medium. The ratio of phosphocreatine concentration to ATP concentration was approximately 2.1. Also, intracellular pH and Mg(2+) concentration ([Mg(2+)](i)), estimated from the chemical shifts of inorganic phosphate and ATP, were comparable with those under retrograde perfusion. [Mg(2+)](i) was significantly increased by the removal of extracellular Na(+), supporting the essential role of Na(+)-coupled Mg(2+) transport in Mg(2+) homeostasis of the heart. Heart slice preparation could also be used to evaluate the potency of cardiac drugs, regardless of their possible effects on coronary microcirculation.

Adenosine Triphosphate↗

Iris movement mediates vascular apoptosis during rat pupillary membrane regression.

In the course of mammalian lens development, a transient capillary meshwork known as the pupillary membrane (PM) forms, which is located at the pupil area; the PM nourishes the anterior surface of the lens and then regresses to make the optical path clear. Although the involvement of apoptotic process has been reported in the PM regression, the initiating factor remains unknown. We initially found that regression of the PM coincided with the development of iris motility, and iris movement caused cessation and resumption of blood flow within the PM. Therefore, we investigated whether the development of the iris's ability to constrict and dilate functions as an essential signal that induces apoptosis in the PM. Continuous inhibition of iris movement with mydriatic agents from postnatal day 7 to day 12 suppressed apoptosis of the PM and migration of macrophage toward the PM, and resulted in the persistence of PM in rats. The distribution of apoptotic cells in the regressing PM was diffuse and showed no apparent localization. These results indicated that iris movement induced regression of the PM by changing the blood flow within it. This study suggests the importance of the physiological interactions between tissues-in this case, the iris and the PM-as a signal to advance vascular regression during organ development, and defines a novel function of the iris during ocular development in addition to the well-known function, that is, optimization of light transmission into the eye.

Animals↗

Systemic nitric oxide production rate during hemodialysis and its relationship with nitric oxide-related factors.

BACKGROUND/AIMS: Nitric oxide (NO) plays a key role in the regulation of vascular tone and controls both local and systemic hemodynamics. Here, we estimated systemic NO production rates of hemodialysis (HD) patients, based on the time course of plasma concentration of nitrate (an oxidative end product of NO) and investigated possible roles of NO-related factors. METHODS: We measured plasma concentrations of nitrate, L-arginine (a substrate of NO synthase: NOS), asymmetric dimethylarginine (ADMA, an endogenous NOS inhibitor), tetrahydrobiopterin (BH4, a NOS cofactor), dihydrobiopterin (BH2, an oxidized form of BH4) and oxidized low-density lipoprotein (oxyLDL; an index of oxidative stress) before and after 30-min and 4-hour HD (n = 10). RESULTS: The time-averaged NO production rate during HD was estimated by fitting the time course of plasma nitrate concentration with a single-compartment model (4.00 +/- 0.82 micromol/min, 4.99 +/- 1.08 micromol/kg/h). The L-arginine/ADMA ratio (L-arginine availability) after 30-min HD showed a positive correlation with the NO production rate (p < 0.05). CONCLUSION: The systemic NO production rate during HD could be estimated by the single-compartment analysis. The L-arginine/ADMA ratio seems to play an important role in the regulation of the NO production during HD.

Arginine↗

Evaluation of bioavailability of nitric oxide in coronary circulation by direct measurement of plasma nitric oxide concentration.

Although bioavailability of NO in the coronary circulation is commonly evaluated by acetylcholine (ACh)-induced vasodilation, a change in plasma NO concentration and its relation to the flow response after injection of ACh are still unknown. Thus, we directly measured the concentration of NO in the coronary sinus by using a catheter-type NO sensor for coronary sinus. An NO-sensitive sensor was located and fixed in a 4-Fr catheter with a soft tip for protection of vascular wall. After calibration with an NO-saturated pure water, the catheter-type NO sensor was located in the coronary sinus in anesthetized dogs. The coronary flow velocity (CFV) was measured with a Doppler guide wire. Intracoronary injection of ACh (0.4 and 1.0 microg/kg) increased plasma NO concentration in a dose-dependent manner (3-10 nM). Although ACh increased CFV by 95%, there was no significant difference between the two ACh doses. After ACh, the peak value of plasma NO concentration was observed significantly later than CFV. N(G)-methyl-L-arginine (NO synthase inhibitor) decreased basal NO concentration by 3 nM and suppressed the ACh-induced NO synthesis with no significant change in average peak velocity. We conclude that production of NO in the coronary circulation can be evaluated in the coronary sinus. Although ACh increases both CFV and NO concentration, CFV dose not reflect NO concentration in terms of magnitude and time course. Direct measurement of plasma NO concentration by the catheter-type NO sensor is useful to evaluate bioavailability of NO in the coronary circulation.

Acetylcholine↗

Hollow-fiber blood-dialysis membranes: superoxide generation, permeation, and dismutation measured by chemiluminescence.

The interaction of blood with a material surface results in activation of the body's humoral immune system and the generation of reactive oxygen species (ROS). It has recently become clear that ROS are central to the pathology of many diseases. In this study, we evaluated the superoxide generation, permeation, and dismutation in hollow-fiber dialysis membranes by using 2-methyl-6-p-methoxyphenylethynyl-imidazopyrazinone (MPEC) as a superoxide-reactive chemiluminescence producer and an optical fiber probe to detect the resulting chemiluminescence in the hollow fiber lumen. We measured the superoxide generated when bovine blood leukocytes were brought into contact with dialysis membranes. Superoxide permeation was determined by measuring MPEC chemiluminescence in the hollow fiber lumen using an optical fiber probe. Additionally, superoxide dismutation was evaluated by examining the difference in superoxide permeability for membranes with and without vitamin E coating. Superoxide generation varies for different membrane materials, depending on the membrane's biocompatibility. Superoxide permeability depends on the diffusive permeability of membranes. No marked decrease in superoxide permeability was observed among membrane materials. The superoxide permeability of vitamin E-coated membrane was smaller than that of uncoated membrane. The antioxidant property of vitamin E-coated membranes is hence effective in causing superoxide dismutation.

Animals↗

Regression of capillary network in atrophied soleus muscle induced by hindlimb unweighting.

Little is known about the mechanisms responsible for the adaptation and changes in the capillary network of hindlimb unweighting (HU)-induced atrophied skeletal muscle, especially the coupling between functional and structural alterations of intercapillary anastomoses and tortuosity of capillaries. We hypothesized that muscle atrophy by HU leads to the apoptotic regression of the capillaries and intercapillary anastomoses with their functional alteration in hemodynamics. To clarify the three-dimensional architecture of the capillary network, contrast medium-injected rat soleus muscles were visualized clearly using a confocal laser scanning microscope, and sections were stained by terminal deoxynucleotidyltransferase-mediated dUTP nick-end labeling (TUNEL) and with anti-von Willebrand factor. In vivo, the red blood cell velocity of soleus muscle capillaries were determined with a pencil-lens intravital microscope brought into direct contact with the soleus surface. After HU, the total muscle mass, myofibril protein mass, and slow-type myosin heavy chain content were significantly lower. The number of capillaries paralleling muscle fiber and red blood cells velocity were higher in atrophied soleus. However, the mean capillary volume and capillary luminal diameter were significantly smaller after HU than in the age-matched control group. In addition, we found that the number of anastomoses and the tortuosity were significantly lower and TUNEL-positive endothelial cells were observed in atrophied soleus muscles, especially the anastomoses and/or tortuous capillaries. These results indicate that muscle atrophy by HU generates structural alterations in the capillary network, and apoptosis appears to occur in the endothelial cell of the muscle capillaries.

Animals↗

Measurement of acetylcholine-induced endothelium-derived nitric oxide in aorta using a newly developed catheter-type nitric oxide sensor.

Intra-aortic measurement of nitric oxide (NO) would provide valuable insights into NO bioavailability in systemic circulation and vascular endothelial function. In the present study, we thus developed a catheter-type NO sensor to measure intra-aortic NO concentration in vivo. An NO sensor was encased and fixed in a 4-Fr catheter. The sensor was then located in the thoracic aorta via the femoral artery through a 7-Fr catheter to measure intra-aortic plasma NO concentration in vivo in anesthetized dogs. Infusion of acetylcholine (10 microg/kg) increased base-to-peak plasma NO level in the aorta by 2.4+/-0.4 nM (n=7). After 20-min infusion of N(G)-methyl-L-arginine (NO synthase inhibitor), changes in plasma NO concentration in response to acetylcholine were attenuated significantly (1.8+/-0.4 nM, P<0.003, n=7). In conclusion, the newly developed catheter-type NO sensor successfully measured acetylcholine-induced changes in intra-aortic plasma concentration of endothelium-derived NO in vivo and demonstrated applicability to direct evaluation of intravascular NO bioavailability.

Acetylcholine↗

Evaluation of basic performance and applicability of a newly developed in vivo nitric oxide sensor.

Direct measurement of nitric oxide (NO) is of great importance and value for both in vitro and in vivo studies on dynamic NO bioactivity. Here, we evaluated the basic performance of a newly developed NO sensor (Innovative Instruments, Inc.). Unlike other NO sensors, the new NO sensor has a highly durable, gas-permeable coating and is affected much less by electrical interference due to its integrated structure where working and reference electrodes are combined in a single element. Calibration with NO gas showed high sensitivity of about 580 pA per nmol-NO l(-1) (the detection limit 0.08 nmol-NO l(-1), S/N = 3). This sensor also showed high selectivity (25,000 times and more) to NO, compared with NO-related reagents such as L-arginine, N(G)-monomethyl-L-arginine, acetylcholine, nitroglycerin (NTG) and tetrahydrobiopterin as well as dissolved oxygen. As an in vivo application, the sensor was located in the anaesthetized rat abdominal aorta to measure NTG-derived plasma NO. lntra-aortic infusion of 0.5 mg NTG caused a measurable increase in plasma NO level (2.0 +/- 2.2 nmol l(-1), mean +/- SD, n = 3). In conclusion, the new NO sensor demonstrated a satisfying performance for both in vitro and in vivo applications.

Acetylcholine↗

Development of a contamination free 6 valve injector inline monitoring system for endotoxin measurement in dialysate.

Use of dialysate as supplement fluid in hemodiafiltration requires controlling contamination by endotoxin of the dialysate. We thus aimed at developing an endotoxin monitoring system with complete exclusion of endotoxin contamination for simple, easy, and accurate measurement of endotoxin concentration in dialysate. In the present study, we used a 6 valve injector along with a high performance liquid chromatogram system. This new system showed a sensitivity of approximately 1 endotoxin units (EU)/L in the range of 0 to 30 EU/L endotoxin in dialysate and no trace of endotoxin contamination. In conclusion, the new endotoxin monitoring system showed high sensitivity and reproducibility, with easy operation.

Endotoxins↗