PubMed Health⌕ Search

Biomedical subjects

Takehisa Matsuda

Publications and source records attributed to Takehisa Matsuda.

At least 19 recordsLinked to original sources

Shape-engineered fibroblasts: cell elasticity and actin cytoskeletal features characterized by fluorescence and atomic force microscopy.

The regulation of cell shape, which determines cell behaviors including adhesion, spreading, migration, and proliferation in an engineered artificial extracellular milieu, is an important task in tissue engineering and in development of functional biomaterials. To deepen the understandings of shape-dependent cell mechanics, the cell elasticity and structural features of the actin cytoskeleton (CSK) were characterized for shape-engineered fibroblasts; round and spindle-shaped cells cultured on photolithographically microprocessed surfaces, employing the cellular microindentation tests and fluorescence observation of actin CSK by the combination of atomic force microscopy (AFM) and fluorescence microscopy (FM). The relationships among cell elasticity, the structural features of actin CSK, and engineered cell shape were analyzed and compared with those of control cells that had been cultured on nonprocessed surfaces (termed naturally extended cells). Results showed that the spindle-shaped cells with sparse or no apical stress fibers (ASFs) exhibited similar stiffness to that of the naturally extended cells with dense ASFs. The elasticity of spindle-shaped cells was affected only slightly by the stress fiber (SF) density, which is in marked contrast to the significant correlation shown between cell elasticity and SF density in naturally extended cells. This result implies that the elasticity of regionally restricted adhesion-surface-induced shape-engineered cells, particularly of highly elongated cells, is affected predominantly by cell shape rather than by structural features of SFs.

3T3 Cells↗

Shape-engineered vascular endothelial cells: nitric oxide production, cell elasticity, and actin cytoskeletal features.

Single cell shape determines cellular functions. Therefore, control of cell shape is of considerable importance for the tissue engineering field. This study was designed to assess the effect of surface-induced shaping of vascular endothelial cells (ECs) on the intracellular nitric oxide (NO) production level, the cell elasticity, and cytoskeletal (CSK) features on shape-engineered ECs (round, 90, 120 microm diameter; spindle-shaped, 20, 30, 40 microm width) prepared on a photolithographically microprocessed surface. Intracellular NO production was measured using a microscopic spectrometer with diaminofluorescein diacetate probe. Cell elasticity and actin CSK features were analyzed through microindentation measurement and fluorescence observations with fluorescence and atomic force microscopy. Results showed that spindle-shaped cells exhibited lower NO production, higher cell stiffness, and denser actin stress fibers than the round and nonrestrictedly cultured control cells. Relations between cell shape with NO production, cell elasticity, and actin CSK features were discussed.

Actins↗

The effect of gradually graded shear stress on the morphological integrity of a huvec-seeded compliant small-diameter vascular graft.

The premature endothelialization of tissue-engineered grafts had often induced cellular detachment at an early period of implantation in arterial circulation, resulting in occlusion at an early period of implantation. This study was aimed to determine whether gradually increased shear stress applied ex vivo improves cell retention and tissue morphological integrity including cell shape and alignment, actin fiber alignment and expression of vascular endothelial (VE) cadherin. Tissue-engineered grafts used for this study were human umbilical vein endothelial cell (HUVEC)-seeded compliant small-diameter grafts made of poly(L-lactide-co-epsilon-caprolactone) fiber meshes fabricated by electrospinning. The shear stresses applied to grafts, generated using a custom-designed mock circulatory apparatus, were 3.2, 8.7 and 19.6 dyn/cm(2). The grafts completely monolayered prior to shear stress exposure exhibited a polygonal cobblestone morphology with randomly distributed actin fibers and VE cadherin at the continuous peripheral region of adjacent cells. The 24-h-loading of high shear stresses (8.7 and 19.6 dyn/cm(2)) equivalent to those of the arterial circulatory system resulted in severe cellular damage resulting in the complete loss of cells. However, a gradually increased graded exposure from a low (3.2 dyn/cm(2)) to a high shear stress (19.6 dyn/cm(2)) resulted in a markedly reduced cell detachment, a highly elongated cell shape, and orientation or alignment of both cells and actin fibers, which were parallel to the direction of flow. Although VE-cadherin expression was not detected yet, a higher degree of tissue integrity was achieved, which may greatly improve the performance particularly at an early period of implantation.

Arteries↗

Structural features and mechanical properties of in situ-bonded meshes of segmented polyurethane electrospun from mixed solvents.

The relationships between the structural features and mechanical properties of electrospun segmented polyurethane (SPU) meshes and electrospinning parameters such as formulation (e.g., polymer concentration and solvent mixing ratio) and operation parameters (e.g., applied voltage, air gap, and flow rate) were studied with the use of a mixed-solvent system of tetrahydrofuran (THF) and N,N-dimethylacrylamide (DMF). After the relationships between the structure of electrospun SPU and the operation parameters under a fixed SPU concentration of single THF solution were established, SPU was electrospun from the mixed solvent of THF and DMF with different mixing ratios [DMF content: 5, 10, and 30% (v/v)]. Scanning electron microscopy showed that an increase in DMF ratio significantly enhances the degree of bonding between SPU fibers at contact sites and decreases the diameter of fibers formed. The porosimetric characterization showed the following: (1) The porosity of the electrospun SPU meshes decreased with an increase of DMF ratio. (2) The pore size distribution exhibited three representative peaks of different void sizes (i.e., approximately 5, 20, and 70 microm). (3) The proportion of the 20-microm void markedly decreased with an increase in DMF ratio. A tensile test on the meshes showed that an increase in DMF ratio induces an increase in elasticity of the mesh. Such a regulation of the structural features and mechanical properties of electrospun SPU meshes using a mixed-solvent system with low- and high-boiling-point solvents may be useful in the engineering of SPU-fiber based matrices or scaffolds.

Acrylamides↗

New technique of seeding chondrocytes into microporous poly(L-lactide-co-epsilon-caprolactone) sponge by cyclic compression force-induced suction.

The initial requirement for a functional engineered cartilage tissue is the effective and reproducible seeding of chondrocytes into the interior of microporous scaffolds. High seeding efficiency, high cell viability, uniform cell distribution, and short operation time are also essential. We devised a new technique of seeding rabbit chondrocytes into microporous poly(L-lactide-co-epsilon-caprolactone) (PLCL) (porosity, 71- 80%; wall thickness, 2 and 6 mm) sponges under compression force-induced suction using a custom designed loading apparatus. Cell distribution and cell viability were determined using confocal laser scanning microscopy with fluorescent dye-staining techniques. Factors that affect the quality of a cell seeded construct were studied, namely, the porosity and thickness of sponges and suction cycles. Under 1 cycle of suction, an increase in porosity promoted cell seeding efficiency (CSE; defined as the percentage of the number of cells in the sponges relative to the initial number of cells seeded), cell viability (at 1 day post seeding), and a relatively uniform cell distribution, whereas thick sponges exhibited an inhomogeneous cell distribution irrespective of incubation time. Multiple cycles of suction of 5 and 10 at 0.1 Hz significantly improved the CSE, whereas high cell viability was maintained and even spatial cell distribution was achieved in 1 week. This study revealed that our newly developed cell seeding technique with multiple cycles of suction is a promising approach to inoculating cells into microporous sponges with high CSE, high cell viability, and homogeneous cell distribution.

Animals↗

Encapsulation of chondrocytes in photopolymerizable styrenated gelatin for cartilage tissue engineering.

We have developed a photopolymerizable styrenated gelatin that can cross-link through polymerization induced by irradiation with visible light. The purpose of this study was to investigate the feasibility of using photopolymerizable styrenated gelatin as a cell carrier in chondrocyte transplantation. As visible light activates camphorquinone added as a photoinitiator, free radicals induce the polymerization of the gelatin macromer; the styrenated gelatin then becomes cross-linked. Rabbit articular chondrocytes were cultured in styrenated gelatin hydrogels and also in collagen gels as a control. After being cultured in the gels, the cells were collected from both gels and counted. Reverse transcriptase-polymerase chain reaction, histological examination, and quantification of the synthesized glycosaminoglycan were performed. On average, 26% of the embedded cells were collected from the gelatin hydrogel immediately after the crosslinking reaction. The surviving chondrocytes expressed the mRNA of type II collagen and aggrecan core protein and produced a cartilaginous matrix throughout the gelatin after 3 weeks. A slightly insufficient accumulation of the matrix was found in the internal region of the gelatin hydrogels, suggesting that less permeability for nutrients due to the high concentration and closely packed structure resulted in less cell viability. Although some limitations became evident, these results indicate that it may be possible to use photopolymerizable styrenated gelatin as a cell carrier in chondrocyte transplantation.

Animals↗

Mechano-active scaffold design based on microporous poly(L-lactide-co-epsilon-caprolactone) for articular cartilage tissue engineering: dependence of porosity on compression force-applied mechanical behaviors.

An essential component of functional articular cartilage tissue engineering is a mechano-active scaffold, which responds to applied compression stress and causes little permanent deformation. As the first paper of a series on mechano-active scaffold-based cartilage tissue engineering, this study focused on mechanical responses to various modes of loading of compression forces and subsequent selection of mechano-active scaffolds from the biomechanical viewpoint. Scaffolds made of elastomeric microporous poly(L-lactide-co-epsilon-caprolactone) (PLCL) with open-cell structured pores (300 approximately 500 microm) and with different porosities ranging from 71 to 86% were used. The PLCL sponges and rabbit articular cartilage tissue were subjected to compression/unloading tests (0.1 and 0.005 Hz) at 5 kPa, and stress relaxation tests at 10, 30, and 50% strain. The measurements of the maximum strain under loading and residual strain under unloading for compression tests and the maximum stress and equilibrium stress in the stress relaxation test showed that the lower the porosity, the closer the mechanical properties are to those of native cartilage tissue. Among the PLCL sponges, the sponge with 71% porosity appears to be a suitable cartilage scaffold.

Animals↗

Protein-protein interactions of the hyperthermophilic archaeon Pyrococcus horikoshii OT3.

BACKGROUND: Although 2,061 proteins of Pyrococcus horikoshii OT3, a hyperthermophilic archaeon, have been predicted from the recently completed genome sequence, the majority of proteins show no similarity to those from other organisms and are thus hypothetical proteins of unknown function. Because most proteins operate as parts of complexes to regulate biological processes, we systematically analyzed protein-protein interactions in Pyrococcus using the mammalian two-hybrid system to determine the function of the hypothetical proteins. RESULTS: We examined 960 soluble proteins from Pyrococcus and selected 107 interactions based on luciferase reporter activity, which was then evaluated using a computational approach to assess the reliability of the interactions. We also analyzed the expression of the assay samples by western blot, and a few interactions by in vitro pull-down assays. We identified 11 hetero-interactions that we considered to be located at the same operon, as observed in Helicobacter pylori. We annotated and classified proteins in the selected interactions according to their orthologous proteins. Many enzyme proteins showed self-interactions, similar to those seen in other organisms. CONCLUSION: We found 13 unannotated proteins that interacted with annotated proteins; this information is useful for predicting the functions of the hypothetical Pyrococcus proteins from the annotations of their interacting partners. Among the heterogeneous interactions, proteins were more likely to interact with proteins within the same ortholog class than with proteins of different classes. The analysis described here can provide global insights into the biological features of the protein-protein interactions in P. horikoshii.

Genes, Archaeal↗

Photoiniferter-based thermoresponsive graft architecture with albumin covalently fixed at growing graft chain end.

The aim of this study was to develop a novel surface graft architecture in which albumin is covalently fixed at the growing chain end of the hydrophilic polymers: poly(N, N-dimethylacylamide), PDMAM, and poly(N-isopropylacrylamide), PNIPAM. Photoiniferter-based surface-grafted polymers were prepared using either an albuminated iniferter or a nonalbuminated iniferter, both of which were derivatized on glass surfaces, and ultraviolet (UV)-light-irradiated in the presence of a DMAM or NIPAM monomer. Surface chemical composition analysis by X-ray photoelectron spectroscopy, contact angle measurement, immunostaining using fluorescence labeled antibody and the measurement of graft thickness, as determined from force-distance curves obtained in water at 25 degrees C and 37 degrees C by atomic force microscopy, evidenced that the thickness of graft layer increased with photoirradiation time and albumin molecules exist at growing chain ends. For PNIPAM-grafted surfaces, the interconversion between swollen and collapsed graft chains was observed below and above the lower critical solution temperature of PNIPAM. The potential application of a thermoresponsive graft with albumin covalently fixed at its growing chain end was discussed in terms of "active" nonfouling surface design based on the temperature-dependent switching of phase transition.

Acrylic Resins↗

Novel bactericidal surface: Catechin-loaded surface-erodible polymer prevents biofilm formation.

We developed a novel bactericidal surface based on a catechin-loaded surface-erodible polymer. (-)-Epigallocatechin-3-gallate (EGCg), which is the main constituent of tea catechins, showed a dose-dependent inhibitory effect on Escherichia coli biofilm formation and a dose-dependent enhanced destructive effect on biofilm. EGCg-immobilized surfaces were prepared by photopolymerization of liquid biodegradable polyesters. The releasing rate was enhanced with an increase in surface-erosion rate of photocured polymers. Polymers with high releasing capacity dose-dependently reduced biofilm formation on the surfaces. The confocal laser scanning microscopic and scanning electron microscopic observations revealed that EGCg induced biofilm-destructing activities, which include bacterial membrane damage, degradation of exopolysaccharides, and detachment of colonized cells. From these results, potential advantages of the clinical use of catechin-loaded polymer-coated implants or catheters are discussed in terms of a reduced occurrence of biomaterial-centered infections without substantial toxicity or adverse effects.

Anti-Infective Agents↗

Mechanical responses of a compliant electrospun poly(L-lactide-co-epsilon-caprolactone) small-diameter vascular graft.

To design a "mechano-active" small-diameter artificial vascular graft, a tubular scaffold made of elastomeric poly(L-lactide-co-epsilon-caprolactone) fabrics at different wall thicknesses was fabricated using an electrospinning (ELSP) technique. The wall thickness of the fabricated tube (inner diameter; approximately 2.3-2.5 mm and wall thickness; 50-340 microm) increased proportionally with ELSP time. The wall thickness dependence of mechanical responses including intraluminal pressure-induced inflation was determined under static and dynamic flow conditions. From the compliance-related parameters (stiffness parameter and diameter compliance) measured under static condition, the smaller the wall thickness, the more compliant the tube. Under dynamic flow condition (1 Hz, maximal/minimal pressure of 90 mmHg/45 mmHg) produced by a custom-designed arterial circulatory system, strain, defined as the relative increase in diameter per pulse, increased with the decrease in wall thickness, which approached that of a native artery. Thus, a mechano-active scaffold that pulsates synchronously by responding to pulsatile flow was prepared using elastomeric PLCL as a base material and an ELSP technique.

Animals↗

Student Research Award in the Undergraduate Degree Candidate category, 30th Annual Meeting of the Society for Biomaterials, Memphis, Tennessee, April 27-30, 2005. Monocyte/lymphocyte interactions and the foreign body response: in vitro effects of biomaterial surface chemistry.

To determine the effect of biomaterial surface chemistry on leukocyte interaction and activity at the material/tissue interface, human peripheral blood monocytes and lymphocytes were cultured on a series of poly(ethylene terephthalate) (PET)-based biomaterials. Both monocytes and lymphocytes were isolated from whole human blood and separated by a nonadherent density centrifugation method before being plated on PET disks, surface modified by photograft copolymerization to yield hydrophobic, hydrophilic, anionic, and cationic surface properties. Monocytes and lymphocytes were cultured separately, to elicit baseline levels of activity, in direct coculture, to promote direct cell surface interactions, or in an indirect coculture system with both cell types separated by a -0.02-microm Transwell apparatus, to promote indirect paracrine interactions. Monocyte adhesion, macrophage fusion, and lymphocyte proliferation were measured on days 3, 7, 10, and 14 of culture. Results demonstrated that the presence of monocytes increased the activity of cocultured lymphocytes at the biomaterial/tissue interface, while the corresponding presence of lymphocytes increased the activation and fusion of indirectly cocultured monocytes. Biomaterial surface chemistry was also found to have a significant effect on monocyte adhesion and activation, and lymphocyte activity. Hydrophilic surfaces significantly inhibited both initial and longterm monocyte adhesion, and inhibited lymphocyte proliferation at longer time points. Anionic and cationic surfaces both exhibited mild inhibition of monocyte adhesion at prolonged time points and increased levels of macrophage fusion, while cationic surfaces decreased levels of lymphocyte proliferation and inhibited monocyte activity. These results elucidate the complex role of juxtacrine and paracrine interactions between monocytes and lymphocytes in the foreign body response, as well as promote the consideration of hydrophilic surfaces in future designs of implantable biomedical devices and prostheses.

Biocompatible Materials↗

Photo-iniferter-based thermoresponsive block copolymers composed of poly(ethylene glycol) and poly(N-isopropylacrylamide) and chondrocyte immobilization.

A series of thermoresponsive poly(N-isopropylacrylamide) (PNIPAM)-poly(ethylene glycol) (PEG) block copolymers with various PNIPAM contents and copolymer architectures, such as linear, four-armed and eight-armed configurations, were prepared by iniferter-based photopolymerization of dithiocarbamylated PEGs (DC-PEGs) under ultraviolet (UV)-light irradiation. The increase in monomer/DC-PEG feed ratio resulted in an increase in both the molecular weight and PNIPAM content of copolymers. The measurement of the optical transmittances of aqueous solutions of PNIPAM-PEG block copolymers determined the lower critical solution temperatures (LCSTs) of block copolymers, which ranged from 31.3 to 34.0 degrees C. LCST decreased with increasing block length of PNIPAM and with the formation of a branched architecture. Rabbit chondrocytes were immobilized and cultured in a three-dimensional (3D) gel composed of PNIPAM-PEG block copolymer at 37 degrees C. Gels prepared from copolymers with higher PNIPAM contents at higher concentrations appeared to exhibit a minimal decrease in both cell number and cell viability during a 7-day culture. Cell viability dependencies on material and formulation parameters and the potential use of PNIPAM-PEG block copolymers as an in situ formable scaffold for an engineered cartilage tissue were discussed.

Acrylic Resins↗

Mechano-active scaffold design of small-diameter artificial graft made of electrospun segmented polyurethane fabrics.

To fabricate a "mechano-active" tubular scaffold of nonwoven mesh-type small-diameter artificial graft made of the synthetic durable elastomer, segmented polyurethane, the fabrication technique of electrospinning on a mandrel under a high rotation speed and transverse movement was used. Emphasis was placed on how the rotation speed of the mandrel and the fusion or welding states of fibers at contact points affect the compliance (ease of intraluminal pressure-dependent circumferential inflation) and Young's modulus determined by uniaxial stretching in the longitudinal and circumferential directions. The results showed that a high rotation speed is attributed to exhibit isotropic mechanical properties in the entire range of applied strain but reduces the compliance, and a high fusion state, which is produced using a mixed solvent with a high content of high-boiling-point solvent, reduces the compliance but is expected to exhibit high durability in a continuously loaded pulsatile stress field in an arterial circulatory system.

Artificial Organs↗

New infusion device for trans-tissue, sustained local delivery of anticancer agent to surgically resected tissue: potential use for suppression of local recurrence of pancreatic cancer.

Local recurrence is a major cause of death of patients who have undergone resection for pancreatic cancer. To reduce the incidence of local recurrence, a new drug-infusion device, which is fixed on resected tissues immediately after surgery, was devised for trans-tissue, sustained local delivery. The drug-infusion device proposed here has the following functions: tight adhesion of the device on resected tissues, sustained drug infusion to the tissue, drug reloading, and easy removal from the body after use. The fabricated prototype experimental device, described here, was a thin infusion pouch made of a thin elastomer film (segmented polyurethane), which is connected to an elastomeric tube for drug reloading. The suppressive effect of the device delivering the anticancer agent, gemcitabine (GEM), was examined using subcutaneous tumor-bearing athymic mouse. A low-dose, local sustained GEM delivery using the device significantly suppressed the tumor growth and regrowth after surgery. The preliminary model experimental result appears to provide a promising therapeutic procedure for increased survival rate of the patients undergoing surgery for pancreatic cancer.

Animals↗

Mesoscopic spatial designs of nano- and microfiber meshes for tissue-engineering matrix and scaffold based on newly devised multilayering and mixing electrospinning techniques.

To design a mesoscopically ordered structure of the matrices and scaffolds composed of nano- and microscale fiber meshes for artificial and tissue-engineering devices, two new electrospinning techniques are proposed: multilayering electrospinning and mixing electrospinning. First, the following four kinds of component polymers were individually electrospun to determine the conditions for producing stable nano- and microfibers by optimizing the formulation parameters (solvent and polymer concentration) and operation parameters (voltage, air gap, and flow rate) for each polymer: (a) type I collagen, (b) styrenated gelatin (ST-gelatin), (c) segmented polyurethane (SPU), and (d) poly(ethylene oxide). A trilayered electrospun mesh, in which individual fiber meshes (type I collagen, ST-gelatin, and SPU) were deposited layer by layer, was formed by sequential electrospinning; this was clearly visualized by confocal laser scanning microscopy. The mixed electrospun-fiber mesh composed of SPU and PEO was prepared by simultaneous electrospinning on a stainless-steel mandrel with high-speed rotation and traverse movement. A bilayered tubular construct composed of a thick SPU microfiber mesh as an outer layer and a thin type I collagen nanofiber mesh as an inner layer was fabricated as a prototype scaffold of artificial grafts, and visualized by scanning electron microscopy.

Biocompatible Materials↗

The potential of poly(N-isopropylacrylamide) (PNIPAM)-grafted hyaluronan and PNIPAM-grafted gelatin in the control of post-surgical tissue adhesions.

Poly(N-isopropylacrylamide)-grafted hyaluronan (PNIPAM-HA) and PNIPAM-grafted gelatin (PNIPAM-gelatin), which exhibit sol-to-gel transformation at physiological temperature, were applied as control of tissue adhesions: tissue adhesion prevention material and hemostatic aid, respectively. The rat cecum, which was abraded using surgical gauze, was coated with PNIPAM-HA-containing PBS (concentration: 0.5 w/v%). The coated solution was immediately converted to an opaque precipitate at body temperature, which weakly adhered to and covered the injured rat cecum. One week after coating, tissue adhesion between the PNIPAM-HA-treated cecum and adjacent tissues was significantly reduced as compared with that between non-treated tissue and adjacent tissues. On the other hand, the coating of bleeding spots of a canine liver with PNIPAM-gelatin-containing PBS (concentration: 20 w/v%) resulted in spontaneous gel formation on the tissues and subsequently suppressed bleeding. Although these thermoresponsive tissue adhesion prevention and hemostatic materials are still prototypes at this time, both thermoresponsive biomacromolecules bioconjugated with PNIPAM, PNIPAM-HA and PNIPAM-gelatin, may serve as a tissue adhesion prevention material and hemostatic aid, respectively.

Acrylic Resins↗

Photo-polymerized microarchitectural constructs prepared by microstereolithography (muSL) using liquid acrylate-end-capped trimethylene carbonate-based prepolymers.

Precision microarchitectural constructs made of acrylated trimethylene carbonate (TMC)-based liquid prepolymers were photo-polymerized using a custom-designed microstereolithographic apparatus. In this study, three different photo-polymerizable liquid prepolymers were prepared by the polymerization of TMC with a low molecular weight poly(ethylene glycol) (PEG) (mol. wt. 200 or 1000); designated as PEG200 or PEG1000, respectively or trimethylolpropane (TMP) as an initiator, and subsequently end-capped with an acrylate group. As a result of layer-by-layer photo-irradiation of the prepolymer with a movable ultraviolet light pen driven by computer-aided design, a three-dimensional (3D) micropillar array, a microbank array, a microcone array, and multi-microtunnels formed on a platform plate or a glass plate were precisely fabricated. The PEG-based polymers exhibited a very low cell adhesion potential, whereas the TMP-based hydrophobic polymer exhibited high cell adhesion and proliferation potentials. The microbank array, which consisted of a plate made of the TMP-based polymer and microbanks made of the PEG200-based polymer, caused cell adhesion and proliferation only on the plate. Upon the implantation of microcone arrays under the subcutis of rats, the photo-polymerized construct made of the poorly swellable PEG200-based polymer exhibited only surface erosion and limited drug loading and releasing potentials. On the other hand, the photo-polymerized construct made of the highly swellable PEG1000-based polymer exhibited not only surface erosion but also bulk erosion and high drug loading and releasing potentials. In this paper, we discuss their potential biomedical applications.

3T3 Cells↗