PubMed Health⌕ Search

Biomedical subjects

Takeo Ishigaki

Publications and source records attributed to Takeo Ishigaki.

At least 19 recordsLinked to original sources

Prostate cancer detection with 3-T MRI: comparison of diffusion-weighted and T2-weighted imaging.

OBJECTIVE: To compare the clinical value of diffusion-weighted (DW) and T2-weighted (T2W) imaging in detecting prostate cancer using a 3-Tesla (3T) magnetic resonance (MR) system. MATERIALS AND METHODS: Thirty-seven patients with suspected prostate cancer underwent T2W and DW imaging at 3T using an 8-channel phased-array coil. These images and apparent diffusion coefficient (ADC) maps were read retrospectively and blindly. The results were compared with histopathologic findings, and receiver operating characteristic (ROC) analysis was used to compare the cancer detection performance of T2W and DW imaging. RESULTS: The areas under the ROC curves for DW imaging and T2W imaging were 0.89 and 0.82, respectively. The performance of DW imaging in prostate cancer detection was significantly better than that of T2W imaging (P=0.0371). CONCLUSION: With a 3T MR system, the performance of DW imaging in detecting prostate cancer was better than that of T2W imaging. DW imaging appears to be a robust and reliable method to examine the whole prostate within an acceptable scan time in clinical settings.

Adenocarcinoma↗

CT depiction of small arteries in the pancreatic head: assessment using coronal reformatted images with 16-channel multislice CT.

BACKGROUND: To assess the capabilities of 16-channel multislice CT in acquiring almost exclusively arterial-phase images of the pancreas and depicting small pancreatic arteries in coronal reformatted images. MATERIALS AND METHODS: In 45 consecutive patients, arterial-phase contrast enhancement was measured in the aorta and its branches, portal venous system, and pancreas. Coronal reformatted images of 1.2- or 1.3-mm slice thickness at 0.8- or 0.9-mm intervals were generated from axial images acquired with 0.5-mm collimation. Two radiologists evaluated the quality of imaging in the arterial phase and the visibility of the pancreatic arteries in coronal reformatted images. RESULTS: Mean enhancement in the aorta and its branches was greater than 300 HU, while that in the portal venous system and pancreas was less than 100 HU. The images were judged to be suitable for delineating the pancreatic arteries in all patients. The following arteries were visualized: anterior superior pancreaticoduodenal (39 patients), posterior superior pancreaticoduodenal (41), anterior inferior pancreaticoduodenal (39), posterior inferior pancreaticoduodenal (33), dorsal pancreatic (42), its right branch (34), and transverse pancreatic (37). CONCLUSION: Multislice CT can depict small pancreatic arteries using coronal reformatted images generated from almost exclusively arterial-phase axial images acquired with 0.5-mm collimation.

Adult↗

Diagnostic value of curved multiplanar reformatted images in multislice CT for the detection of resectable pancreatic ductal adenocarcinoma.

The purpose of this study was to assess the usefulness of curved multiplanar reformatted (MPR) images obtained by multislice CT for the depiction of the main pancreatic duct (MPD) and detection of resectable pancreatic ductal adenocarcinoma. This study included 28 patients with pancreatic carcinoma (size range 12-40 mm) and 22 without. Curved MPR images with 0.5-mm continuous slices were generated along the long axis of the pancreas from pancreatic-phase images with a 0.5- or 1-mm slice thickness. Seven blinded readers independently interpreted three sets of images (axial images, curved MPR images, and both axial and curved MPR images) in scrolling mode. The depiction of the MPD and the diagnostic performance for the detection of carcinoma were statistically compared among these images. MPR images were significantly superior to axial images in depicting the MPD, and the use of both axial and MPR images resulted in further significant improvements. For the detection of carcinoma, MPR images were equivalent to axial images, and the diagnostic performance was significantly improved by the use of both axial and MPR images. High-resolution curved MPR images can improve the depiction of the MPD and the diagnostic performance for the detection of carcinoma compared with axial images alone.

Adult↗

Relationship between CT densitometry with a slice thickness of 0.5 mm and audiometry in otosclerosis.

The appropriate cutoff Hounsfield unit (HU) value for the diagnosis of otosclerosis was determined and the correlation between the bone conduction threshold and the findings of computed tomography (CT) densitometry investigated. CT images, 0.5-mm thick, were evaluated in 24 ears with otosclerosis and 19 control ears. Eight regions of interest were set around the otic capsule. The mean HU values in the area anterior to the oval window (A-OW) and anterior to the internal auditory canal (A-IAC) were significantly lower in otosclerosis than in controls. Based on receiver operating characteristic (ROC) analysis, the cutoff HU value in A-OW was determined to be 2,187.3 HU. The mean HU value in retrofenestral otosclerosis was significantly lower in the area A-OW, A-IAC and around the cochlea than in controls. Based on ROC analysis, the cutoff HU value in the latter was determined to be 2,045 HU. A statistically significant correlation was found between the density of the area A-OW and the hearing level at 500 and 1,000 Hz, and between the density of the area around the cochlea and the hearing level at most frequencies. These results suggest the semi-automated diagnosis of otosclerosis may be possible.

Absorptiometry, Photon↗

Influence of rib structure on detection of subtle lung nodules.

PURPOSE: To access the influence of anatomic noise on the detectability of subtle lung nodules depicted on chest radiographs. MATERIAL AND METHODS: From normal chest radiography images, 132 square regions were extracted, of which the centers were on the upper margin of a rib, the inside of a rib, the lower margin of a rib, and the central region between two adjoining ribs. Simulated nodules were digitally superimposed at the centers of these extracted square images. Twelve radiologists viewed 50 soft-copy images consisting of these 792 processed images, including the noise-added images. The observer's confidence level for the square images containing single nodules was used as an index of observer performance. RESULTS: Results indicated statistically reliable effects of the relationship between rib structures and nodule positions on the detection performance (P < 0.001). The nodule detectability on the images with a center located between two adjoining ribs was significantly the best, whereas it was significantly the worst on the noise-added images with a center located between two adjoining ribs. CONCLUSION: The rib structures overlying a subtle lung nodule on chest X-ray images have a detrimental effect on nodule detection performance as anatomic noise, regardless of the nodule location on ribs.

Adult↗

Intraarterial cisplatin/nedaplatin and intravenous 5-fluorouracil with concurrent radiation therapy for patients with high-risk uterine cervical cancer.

OBJECTIVE: The purpose of this study was to determine the effectiveness of the combination of intraarterial and intravenous concurrent chemoradiation therapy (CIAIV-CCRT) for the treatment of high-risk uterine cervical cancer. METHODS: Between January 2000 and November 2004, we reviewed 45 cervical cancer patients treated by CIAIV-CCRT. The numbers of patients with stage IB2, IIA, IIB, IIIA, IIIB, and IVA were 3, 6, 14, 1, 17, and 4, respectively. Patients with stage III and IVA or patients with tumors >3 cm in diameter were enrolled in this study. Two sessions of CCRT were administered every 3 weeks using a combination of 70 mg/m2 x h(-1) cisplatin or 50 mg/m2 x h(-1) nedaplatin via the bilateral uterine artery and 2800 mg/m2 x 96 h(-1) 5-fluorouracil intravenously. Patients concurrently received external beam radiation therapy and brachytherapy. A nonrandomized control group of 47 patients who underwent radiation therapy alone between 1993 and 2000 was used for comparison. RESULTS: Of the 45 patients, 28 (62%) exhibited complete response and 16 (36%) exhibited partial response. One IIIB patient (2%) did not show any response. The 5-year overall survival (OAS) rates in the CCRT group and control group were 80.6% and 54.9%, respectively. With regard to late toxicities, no statistically significant differences were observed between the two groups. In uni- and multivariate analyses, positive pelvic lymph node showed a statistically significant influence on the OAS in the CIAIV-CCRT group (P = 0.049). CONCLUSION: These preliminary results suggest that CIAIV-CCRT can improve the prognosis of patients with high-risk cervical cancer.

Adult↗

An abnormal accumulation of fluorine-18-FDG PET in cytomegalovirus enteritis--a case report.

The source of a fever of unknown origin (FUO) and watery diarrhea in a 63-yr-old female with a history of disturbance of consciousness due to moyamoya disease was examined. Fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET), colonoscopy, blood analysis, and determination of cytomegalovirus (CMV) antigenemia were performed. FDG was found to be accumulated in the wall of a dilated colon, and extended from the transverse to sigmoid colon. Colonoscopy revealed edematous, inflammatory, and punched out lesions in accordance with the areas of abnormal FDG uptake. A biopsy specimen showed the antibody of CMV in the colonic mucosa, and CMV antigenemia was detected by an immunohistochemical assay using a monoclonal antibody for CMV pp65 antigen. From these findings, we strongly suspected CMV enteritis.

Cytomegalovirus↗

Cerebral glucose metabolism change in patients with complex regional pain syndrome: a PET study.

PURPOSE: The aim of this study was to examine abnormalities of the central nervous system in patients with chronic pain who were diagnosed with complex regional pain syndrome (CRPS). MATERIALS AND METHODS: Brain activity was assessed using (18)F-fluorodeoxyglucose positron emission tomography. The data collected from 18 patients were compared with data obtained from 13 normal age-matched controls. RESULTS: Our results showed that glucose metabolism was bilaterally increased in the secondary somatosensory cortex, mid-anterior cingulated cortex (ACC) or posterior cingulated cortex (PCC) (or both), parietal cortex, posterior parietal cortex (PPC), and cerebellum as well as in the right posterior insula and right thalamus in our patients. In contrast, glucose metabolism was reduced contralaterally in the dorsal prefrontal cortex and primary motor cortex. Glucose metabolism was bilaterally elevated in the mid-ACC/PCC and the PPC, which correlated with pain duration. CONCLUSION: These data suggested that glucose metabolism in the brains of patients with CRPS changes dramatically at each location. In particular, glucose metabolism was increased in the areas concerned with somatosensory perception, possibly due to continuous painful stimulation.

Adult↗

The effect of patient age on contrast enhancement during CT of the pancreatobiliary region.

OBJECTIVE: The objective of our study was to assess whether it is possible to reduce the dose and rate of contrast material injection in elderly patients in triple-phase contrast-enhanced CT of the pancreatobiliary region with an MDCT scanner. SUBJECTS AND METHODS: One hundred twelve patients were divided into three groups: contrast injection at 0.08 mL/kg body weight/s (an upper limit of 5 mL/s) over 30 seconds in patients 60 years old or younger (group 1, n = 49), the same contrast injection as group 1 in patients more than 60 years old (group 2, n = 32), and contrast injection at 0.07 mL/kg body weight/s (an upper limit of 4.5 mL/s) over 30 seconds in patients more than 60 years old (group 3, n = 31). Contrast enhancement in the aorta, portal venous system, pancreas, and liver was assessed quantitatively. Two radiologists blinded to the patients' clinical information and the injection protocol used to acquire the CT images graded the degree of contrast enhancement using a 5-point scoring system. The results for the different groups were statistically compared. RESULTS: Contrast enhancement in the main phases for all organs was significantly more intense in group 2 than in groups 1 and 3. Cases in which pancreatic enhancement in the pancreatic phase was graded as excessive were more frequently observed in group 2. No statistically significant differences were observed between groups 1 and 3 in either quantitative or visual assessment for enhancement of any organ in any phase. CONCLUSION: We recommend reducing the dose and rate of contrast material injection by at least 10% for elderly patients undergoing MDCT examination of the pancreatobiliary region.

Adult↗

Assessment of anomalous pancreaticobiliary ductal junction with high-resolution multiplanar reformatted images in MDCT.

OBJECTIVE: The objective of our study was to assess the capabilities of MDCT for the diagnosis of an anomalous pancreaticobiliary ductal junction using high-resolution multiplanar reformatted (multiplanar reconstruction) images. MATERIALS AND METHODS: This study included nine patients with and 54 without an anomalous pancreaticobiliary ductal junction confirmed on direct cholangiopancreatography. Multiplanar reconstruction images with 0.5-mm continuous slices were generated from isotropic or nearly isotropic pancreatic phase images. By mainly interpreting the multiplanar reconstruction images using the Scrolling mode, two blinded reviewers independently determined whether the confluence of the pancreatic and biliary ducts joined in the pancreatic parenchyma (in other words, outside the duodenal wall). The results were correlated with the findings of direct cholangiopancreatography. The diagnostic capabilities of CT for revealing associated pancreatobiliary diseases were assessed in patients with this anomaly. RESULTS: Interobserver agreement in the classification of the duct confluence was high (kappa = 0.804). The duct confluence was identified in all patients except four without an anomalous pancreaticobiliary ductal junction. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CT for diagnosing an anomalous pancreaticobiliary ductal junction were 100% (9 of 9 patients), 87% (47 of 54 patients), 89% (56 of 63 patients), 75% (9 of 12 patients), and 100% (47 of 47 patients) in the final decisions, respectively. CT showed all associated pancreatobiliary diseases except bile duct stones in two patients. CONCLUSION: MDCT enabled the diagnosis of an anomalous pancreaticobiliary ductal junction by showing whether the pancreatic and biliary ducts join within the pancreatic parenchyma on high-resolution multiplanar reconstruction images.

Adult↗

Low efficacy of 18F-FDG PET for detection of uveal malignant melanoma compared with 123I-IMP SPECT.

UNLABELLED: Earlier investigations showed that N-isopropyl-p-123I-iodoamphetamine SPECT (123I-IMP SPECT) is useful for the diagnosis of uveal malignant melanoma, whereas the feasibility and usefulness of 18F-FDG PET in uveal malignant melanoma have not yet been established. We compared the usefulness of 123I-IMP SPECT and 18F-FDG PET for the detection of uveal malignant melanoma on the same subjects. METHODS: Nineteen patients (10 men, 9 women) with suspected uveal malignant melanoma were examined by 123I-IMP SPECT. Thirteen of them were also examined by 18F-FDG PET. 123I-IMP SPECT was performed at 15 min or at 3 and 24 h after intravenous administration of 123I-IMP. RESULTS: In 12 of 19 study patients, 123I-IMP SPECT obtained at 24 h after intravenous administration of 123I-IMP delineated an area of increased uptake in the site corresponding to the ocular tumor. All of the ocular tumors in the 12 123I-IMP SPECT-positive patients were confirmed histopathologically and clinically to be uveal malignant melanoma. The other 7 123I-IMP-SPECT-negative patients have been monitored under the diagnosis of choroidal nevus, choroidal hemangioma, hyperplasia of the pigment epithelium of the retina, or idiopathic inflammatory lesions without any complications. In a total of 13 patients examined by 18F-FDG PET, 9 of whom were 123I-IMP SPECT positive and 4 were negative, only 1 patient showed abnormal uptake of 18F-FDG PET in the site corresponding to the ocular tumor. Therefore, 8 of 9 patients with uveal malignant melanoma showed false-negative results in 18F-FDG PET. The 18F-FDG PET-positive patient with uveal malignant melanoma had the largest tumor mass with a short diameter of 12 mm, a long diameter of 17 mm, and a height of 7 mm. In the other 8 18F-FDG PET-negative patients, the tumors had a dimension of 11 x 13 x 7 mm or less. CONCLUSION: 123I-IMP SPECT is a sensitive and accurate method for the detection of uveal malignant melanoma, whereas the efficacy of 18F-FDG PET for this purpose is low because of a high incidence of false-negative results. 123I-IMP SPECT is far more superior in comparison with 18F-FDG PET in detecting uveal malignant melanoma.

Adult↗

Influence of monitor luminance and room illumination on soft-copy reading evaluation with electronically generated contrast-detail phantom: comparison of cathode-ray tube monitor with liquid crystal display.

The influence of monitor brightness and room illumination on soft-copy diagnosis by both cathode-ray tube (CRT) monitor and liquid crystal display (LCD) was evaluated and compared using a contrast-detail phantom. Nine observers (7 radiologists and 2 radiological technicians) interpreted six types of electronically generated contrast-detail phantom images using a 21-inch CRT (2,048x2,560) and a 21-inch LCD (2,048x2,560) under 6 kinds of viewing conditions, i.e. monitor brightness of 330 cd/m2 or 450 cd/m2, and room illumination of 20, 100 or 420 lux at the center of the display. Observers were requested to determine the visible borderline of the objects. Between 330 cd/m2 and 450 cd/m2, no significant difference in the visible area was found under any of the three lighting conditions. However, in two low-contrast phantom images, the visible area on the LCD was significantly larger than that on the CRT, independent of both monitor brightness and room illumination. (p<0.05). The effect of room illumination was not significant, suggesting that the use of LCD at high room illumination is acceptable.

Computers↗

Evaluation of new image processing conditions for digital mammograms from Fuji computed radiography.

PURPOSE: A new processing parameter (T-type parameter) setting for gray scale was developed to improve the image quality of digital mammograms. To clarify the usefulness of this parameter setting, we have evaluated the image quality of digital mammograms (hard copy images) processed with this parameter, and compared it with S/F mammography. MATERIAL AND METHODS: Mammograms were made under the same radiographic conditions by the S/F and FCR systems (type 1, S/F; type 2 and 3, FCR with new T-type parameters; type 4 and 5, FCR with conventional parameters). A total of 49 images from 10 cases was selected for evaluation testing. Evaluation items were the contrast visibility of mammary glands and adipose tissues together with their granularity and sharpness. Eleven medical doctors participated in evaluating the images. RESULTS: The FCR hard copy images processed with the T-type parameter settings were significantly preferred over the conventional S/F images for the contrast visibility of mammary glands and adipose tissue. As for the other items (except for granularity), the FCR hard copy images processed with the T-type parameter settings were subjectively evaluated as slightly better than or equal to the S/F images. In contrast, the conventional S/F images were significantly preferred over the FCR hard copy images processed with the conventional parameter settings. CONCLUSION: The image quality of FCR hard copy images processed with the T-type parameter settings was preferred over that of conventional S/F images as evaluated by medical doctors who specialized in mammography interpretation.

Female↗

Application of subsecond rotation scan to helical CT for lung cancer screening.

PURPOSE: To clarify whether the benefit of a reduced effective scan width obtained using a smaller pitch outweighs the disadvantage of increased noise in the application of a subsecond helical CT to mass screenings for lung cancer. MATERIALS AND METHODS: Twenty-two helical CT scans of the lung were obtained in 11 healthy subjects using the following parameters: 1) scan 1 was performed at 120 kVp, 50 mA, 10-mm collimation, 1-second/rotation, helical pitch of 2.0; and 2) scan 2 was performed at 120 kVp, 50 mA, 10-mm collimation, 0.75-second/rotation, helical pitch of 1.5. Computer-generated nodules measuring 10 mm and 6 mm in diameter showing ground-glass opacity were superimposed on these images. The detectability of each nodule was evaluated by six blinded readers using ROC analysis. RESULTS: Detectability of the 6-mm nodules was significantly higher in scan 2 than in scan 1. Detectability of the 10-mm nodules was not significantly different between scans 1 and 2. CONCLUSION: The use of a smaller pitch by employing a subsecond rotation scan in a helical CT for lung cancer screenings improves the detection of small lesions without increasing either the scanning time or radiation dose.

Adult↗

Intra- and interobserver agreement and performance score of breast phantom image interpretation: influence of ambient room lighting levels.

The influence of ambient room lighting conditions on soft-copy breast phantom image interpretation was evaluated by comparing cathode ray tube (CRT) monitors with liquid crystal displays (LCDs). Nine observers were asked to use a three-point scale to rate the visibility of various phantom objects (masses, specks, and fibers) displayed on a 21-inch CRT (2,560 x 2,048) and a 21-inch LCD (2,560 x 2,048) under three different levels of ambient lighting (20, 100 and 420 lux at the display center). Each phantom image was interpreted twice, and the reproducibility of judgment and inter-observer agreement was evaluated using kappa statistics. Except for the "mass" score, the LCD score showed a significantly higher value (p<0.05) compared with that of CRT. Nevertheless, no significant differences were found among the three lighting levels. Furthermore, intra- and inter-observer agreement in judgments showed no effects of room illumination. Although the breast phantom objects were better visualized on LCDs than on CRT monitors, room illumination did not affect the performance score of soft-copy reading.

Breast Neoplasms↗

Diffusion-weighted imaging of the liver: technical challenges and prospects for the future.

Diffusion-weighted imaging (DWI) has recently been attempted in the abdominal region. We review diffusion-weighted images of the liver, especially from the technical point of view. We discuss selection of pulse sequence parameters, effects of anti-breathing motion technique, tips for measuring apparent diffusion coefficient (ADC), and utility of superparamagnetic iron oxide (SPIO), showing clinical cases, including those at 3T. Our current trial of new pulse sequencing, such as SPIO-mediated breath-holding black-blood fluid-attenuated inversion recovery (BH-BB-FLAIR), imaging is shown. Some prospects for the future in DWI of the liver are also stated.

Adult↗

Measurement of modulation transfer functions for liquid crystal displays by rectangular waveform analysis.

We measured modulation transfer functions (MTFs) of liquid crystal displays (LCDs) by rectangular waveform analysis. This method consists of taking a picture of the bar pattern on the display surface with a digital camera, and analyzing the picture with a personal computer. The displays used are LCDs of 1M (about 1 million pixels), 2M, 3M, and 5M, and a cathode ray tube (CRT) display with a pixel number of 5M. Two kinds of 2M displays were used, an in-plane switching (IPS) system and vertical alignment (VA) system, from which liquid crystal operation mode differs. MTFs increased as pixels increased. For the LCDs, MTFs in the horizontal direction were higher than those in the vertical direction except for the 2M VA system. For the LCD of the 2M VA system, MTF in a horizontal direction was equal to MTF in a vertical direction. For the displays with the same number of pixels (5M), MTF of a LCD was higher than that of a CRT display. MTFs of LCDs are influenced by the pixel form, pixel composition, and the liquid crystal operation mode.

Data Display↗

Observation of contrast enhancement in the cochlear fluid space of healthy subjects using a 3D-FLAIR sequence at 3 Tesla.

In animals, the enhancement of perilymph in the cochlea has been reported using 1.25 mmol/kg of Gd-DTPA, allowing the separate visualisation of perilymph and endolymph for the diagnosis of Meniere's disease. The purpose of this study was three-fold: (1) to determine the optimal timing for detecting cochlear fluid enhancement using 3D-FLAIR (fluid-attenuated inversion recovery) after intravenous administration of 0.1 mmol/kg of Gd-DTPA in healthy human subjects; (2) to examine the reliability of enhancement in multiple healthy subjects; and (3) to investigate whether endolymph and perilymph space can be visually discriminated. In two healthy subjects, 3D-FLAIR images were obtained before, immediately after and 2 h, 4 h and 6 h after the injection. Three more healthy subjects were scanned before and 4 h after the injection. In all four ears of the initial two subjects, cochlear fluid was found to be most intensely enhanced 4 h after the injection. In all of the additional three subjects, the cochlear fluid signal had increased after 4 h from injection. However, visual differentiation of endolymph and perilymph fluid could not be achieved. Using 3D-FLAIR and Gd-DTPA, cochlear fluid enhancement can be observed in healthy human ears, even with a single dose of contrast-medium injection.

Cochlea↗