Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI.

Treatment planning based on probability distribution function (PDF) of patient geometries has been shown a potential off-line strategy to incorporate organ motion, but the application of such approach highly depends upon the reproducibility of the PDF. In this paper, we investigated the dependences of the PDF reproducibility on the imaging acquisition parameters, specifically the scan time and the frame rate. Three healthy subjects underwent a continuous 5 min magnetic resonance (MR) scan in the sagittal plane with a frame rate of approximately 10 f s-1, and the experiments were repeated with an interval of 2 to 3 weeks. A total of nine pulmonary vessels from different lung regions (upper, middle and lower) were tracked and the dependences of their displacement PDF reproducibility were evaluated as a function of scan time and frame rate. As results, the PDF reproducibility error decreased with prolonged scans and appeared to approach equilibrium state in subjects 2 and 3 within the 5 min scan. The PDF accuracy increased in the power function with the increase of frame rate; however, the PDF reproducibility showed less sensitivity to frame rate presumably due to the randomness of breathing which dominates the effects. As the key component of the PDF-based treatment planning, the reproducibility of the PDF affects the dosimetric accuracy substantially. This study provides a reference for acquiring MR-based PDF of structures in the lung.

Artifacts↗

The effects of SNR on ADC measurements in diffusion-weighted hyperpolarized He-3 MRI.

The theoretical dependence of the mean and standard deviation of ADC values on signal-to-noise ratio (SNR) was derived and compared to measured values in porous phantoms and the lungs of human subjects using diffusion-weighted hyperpolarized helium-3 MRI. For SNR values below 15, mean ADC values were highly SNR-dependent due to a combination of noise and choice of noise thresholding. Above SNR values of 15 and for mean ADC values within ranges relevant for evaluating lung disease (<0.6 cm2/s), the mean ADC was largely independent of SNR. The standard deviation, by contrast, was highly dependent on SNR over a much larger range, but this dependence was well predicted by theory, suggesting the histogram of ADC values might be corrected for these stochastic processes to more accurately evaluate disease using restricted diffusion measures in the lungs.

Artifacts↗

Evaluation of emphysema severity and progression in a rabbit model: comparison of hyperpolarized 3He and 129Xe diffusion MRI with lung morphometry.

The apparent diffusion coefficients (ADCs) of hyperpolarized (3)He and (129)Xe gases were measured in the lungs of rabbits with elastase-induced emphysema and correlated against the mean chord length from lung histology. In vivo measurements were performed at baseline and 2, 4, 6, and 8 wk after instillation of elastase (mild and moderate emphysema groups) or saline (control group). ADCs were determined from acquisitions that used two b values. To investigate the effect of b value on the results, b-value pairs of 0 and 1.6 s/cm(2) and 0 and 4.0 s/cm(2) were used for (3)He, and b-value pairs of 0 and 5.0 s/cm(2) and 0 and 10.0 s/cm(2) were used for (129)Xe. At 8 wk after instillation, the rabbits were euthanized, and the lungs were analyzed histologically and morphometrically. ADCs for the rabbits in the control group did not change significantly from baseline to week 8, whereas ADCs for the rabbits in the emphysema groups increased significantly (P < 0.05) for all gas and b-value combinations except (129)Xe with the b-value pair of 0 and 5.0 s/cm(2). The largest percent change in mean ADC from baseline to week 8 (15.3%) occurred with (3)He and the b-value pair of 0 and 1.6 s/cm(2) for rabbits in the moderate emphysema group. ADCs (all b values) were strongly correlated (r = 0.62-0.80, P < 0.001) with mean chord lengths from histology. These results further support the ability of diffusion-weighted MRI with hyperpolarized gases to detect regional and global structural changes of emphysema within the lung.

Animals↗

q-Space analysis of lung morphometry in vivo with hyperpolarized 3He spectroscopy.

PURPOSE: To examine the utility of a (3)He spectroscopic q-space technique for detecting changes in lung morphometry in vivo. MATERIALS AND METHODS: A diffusion-weighted spectroscopy sequence was used to collect global diffusion data from healthy adults (N = 11), healthy children (N = 5), and chronic obstructive pulmonary disease (COPD) patients (N = 2) using 40 cc of hyperpolarized (3)He gas within a two second breathhold. Displacement probability profiles (DPP) were obtained by Fourier transformation of diffusion data with respect to q. A bi-Gaussian model was used to decompose the DPPs into narrow and broad components, characterized by root-mean-square displacements X(rms1) and X(rms2), respectively. RESULTS: In healthy adults, the narrow component (X(rms,1)) of the DPP had a mean displacement of 188 +/- 10 microm, slightly less than the reported average size of the alveoli. The broad component (X(rms,2)) had a mean value of 474 +/- 44 microm, comparable to the diameter of the respiratory bronchioles in the acinus. In children, both X(rms1) (167 +/- 4 microm) and X(rms2) (382 +/- 22 microm) compared to healthy adults (P < 0.01). In COPD patients, the mean displacements were elevated (X(rms1): 265 +/- 71 microm; X(rms2): 530 +/- 109 microm) compared to healthy adults. Excellent correlation was found between rms displacements and age (age vs. X(rms,1): r = 0.78, P < 0.001; age vs. X(rms,2): r = 0.90, P < 0.001). CONCLUSION: The q-space parameters agreed remarkably well with published alveolar morphometry data. The results suggest that the technique may be sensitive to disease, as evident from the elevated mean displacements in COPD patients compared to healthy volunteers. Detailed lung microstructural information can be obtained using a very low volume of inhaled (3)He.

Adult↗

Assessment of lung development using hyperpolarized helium-3 diffusion MR imaging.

PURPOSE: To determine whether hyperpolarized helium-3 (HHe) diffusion MR can detect the expected enlargement of alveoli that occurs with lung growth during childhood. MATERIALS AND METHODS: A total of 29 normal subjects aged four to 30 years underwent HHe diffusion MR imaging with the b-value pair 0, 1.6 second/cm(2). A second acquisition during a separate breathhold was performed using the b-value pair 0, 4 second/cm(2) to evaluate the dependence on b-value. The mean apparent diffusion coefficient (ADC) and lung volume for each acquisition and each subject was determined. RESULTS: Subjects as young as four years of age were able to cooperate with the imaging procedure. The mean ADC increased with increasing subject age (r = 0.8; P < 0.001), with a 55% increase in mean ADC from the youngest to oldest subject. Lung volumes measured on MR were highly repeatable for the two HHe MR acquisitions (r = 0.980, P < 0.001). The mean ADC values measured with the two different b-value pairs were highly correlated (r = 0.975; P < 0.001), but the higher b-value pair resulted in slightly lower mean ADCs (P < 0.001). CONCLUSION: HHe diffusion MR appears to detect the expected increase in alveolar size during childhood, and thus HHe MR may be a noninvasive method to assess development of the lung microstructure.

Adolescent↗

Time dependence of 3He diffusion in the human lung: measurement in the long-time regime using stimulated echoes.

A stimulated-echo-based technique was developed to measure the long-time-scale apparent diffusion coefficient (ADC) of hyperpolarized 3He during a single breath-hold acquisition. Computer simulations were used to evaluate the performance of the technique and guide the selection of appropriate parameter values for obtaining accurate ADC values. The technique was used in 10 healthy subjects and two subjects with chronic obstructive pulmonary disease (COPD) to measure the global ADC for diffusion times between a few tenths of a second and several seconds, and to acquire spatial maps of the ADC for a diffusion time of 1.5 s. The reproducibility of the technique and its sensitivity to the direction of diffusion sensitization were also investigated. In healthy subjects, global ADC values decreased by severalfold over the range of diffusion times measured (mean values = 0.039 and 0.023 cm2/s at diffusion times of 0.61 and 1.54 s, respectively). ADC maps were generally uniform, with mean values similar to the corresponding global values. For the two COPD subjects, global ADC values were substantially greater than those of every healthy subject at all diffusion times measured. In addition, regional elevations of ADC values were far more conspicuous on long-time-scale ADC maps than on short-time-scale ADC maps.

Adult↗

Clinical experience with radiotracer-guided thoracoscopic biopsy of small, indeterminate lung nodules.

BACKGROUND: Although computed tomography lung-screening programs report a 31% to 51% incidence of subcentimeter pulmonary nodules, 85% are too small to biopsy or interrogate with positron emission spectroscopy scans. We developed a technique using transthoracic percutaneous radiotracer injection with thoracoscopic radioprobe localization and excision for small pulmonary nodules. This report describes our series of the first 46 patients evaluated with this technique. METHODS: Forty-six patients (79% smokers; 52% males; median age, 64 years) were evaluated. Patient selection was based on the surgeon's anticipated difficulty in thoracoscopically locating small nodules because of lesion size or location. Computed tomographic-guided injection of radiotracer solution was made into or adjacent to the nodule the day of surgery. Intraoperative gamma probe localization, followed by thoracoscopic excision of the lesion, was subsequently performed. RESULTS: Median nodule size was 9 mm (range, 3 to 22 mm), and median depth was 5 mm (range, 0 to 50 mm). Forty-four (96%) of the lesions were successfully localized and excised. Median time from injection to surgery was 270 minutes. Failures were the result of inadvertent pleural or chest wall radiotracer placement. Forty-six percent (21 of 46) of the lesions were malignant, of which 71% (15 of 21) were primary lung cancers. Patients with lung cancer underwent lobectomy or segmentectomy. Fourteen of 15 were stage IA, whereas 1 was stage IIIB (6 mm primary with 4 mm intralobar metastasis). Complications were three pneumothoraces at the time of radiotracer injection. CONCLUSIONS: Computed tomography-guided radiotracer localization of small pulmonary nodules combined with thoracoscopic excisional biopsy is feasible and safe. This technique successfully localized and excised the nodule in 96% of cases.

Biopsy↗

Evaluation of asthma with hyperpolarized helium-3 MRI: correlation with clinical severity and spirometry.

BACKGROUND: Accurate characterization of asthma severity is difficult due to the variability of symptoms. Hyperpolarized helium-3 MRI (H(3)HeMR) is a new technique in which the airspaces are visualized, depicting regions with airflow obstruction as "ventilation defects." The objective of this study was to compare the extent of H(3)HeMR ventilation defects with measures of asthma severity and spirometry. METHODS: Patients with a physician diagnosis of asthma and normal control subjects underwent H(3)HeMR. For each person, the number and size of ventilation defects were scored and the average number of ventilation defects per slice (VDS) was calculated. The correlations of the imaging findings with measures of asthma severity and spirometry were determined. RESULTS: There were 58 patients with asthma (mild-intermittent, n = 13; mild-persistent, n = 13; moderate-persistent, n = 20; and severe-persistent, n = 12) and 18 control subjects. Mean +/- SE VDS for asthmatics was significantly greater than for control subjects (0.99 +/- 0.15 vs 0.26 +/- 0.22, p = 0.004). Among asthmatics, VDS was significantly higher for the group with moderate-persistent and severe-persistent disease than for the group with mild-intermittent and mild-persistent disease (1.37 +/- 0.24 vs 0.53 +/- 0.12, p < 0.001). VDS correlated significantly with FEV(1)/FVC (r = - 0.51, p = 0.002), forced expiratory flow between 25% and 75% from the beginning of FVC (FEF(25-75%)) percentage of predicted for height, sex, and race (%predicted) [r = - 0.50, p = 0.001], and FEV(1) %predicted (r = - 0.40, p = 0.002), but not with FVC %predicted (r = - 0.26, p = 0.057) and peak expiratory flow %predicted (r = - 0.16, p = 0.231). Many asthmatics had an elevated VDS, but their spirometric indexes, except FEF(25%-75%), were normal. Most ventilation defects were < 3 cm in size for all asthmatics. In the group of patients with moderate-to-severe persistent asthma, there were more defects > or =3 cm than in the group with mild-intermittent and mild-persistent disease (p = 0.021). CONCLUSIONS: Regional changes of airflow obstruction in asthmatics depicted by H(3)HeMR correlate with measures of asthma severity and spirometry.

Adolescent↗

Hyperpolarized HHe 3 MRI of the lung in cystic fibrosis: assessment at baseline and after bronchodilator and airway clearance treatment.

RATIONALE AND OBJECTIVES: The purpose of this study is to determine hyperpolarized helium 3 (HHe) magnetic resonance (MR) findings of the lung in patients with cystic fibrosis (CF) compared with healthy subjects and determine whether HHe MR can detect changes after bronchodilator therapy or mechanical airway mucus clearance treatment. MATERIALS AND METHODS: Thirty-one subjects, 16 healthy volunteers and 15 patients with CF, underwent HHe lung ventilation MR imaging and spirometry at baseline. Eight patients with CF then were treated with nebulized albuterol, after which a follow-up HHe MR scan was obtained. Subsequently, recombinant human deoxyribonuclease (DNase) treatment and chest physical therapy were performed in these eight subjects, followed by a third HHe MR scan. For each MR study, the number of ventilation defects was scored by a human reader. RESULTS: Patients with CF had significantly more HHe MR ventilation defects per image than healthy subjects (mean, 8.2 defects in patients with CF vs 1.6 defects in healthy subjects; P < .05). Even the four subjects with CF with a normal forced expiratory volume in 1 second had significantly more ventilation defects than healthy subjects (mean, 6.5 defects in these patients with CF; P = .0002). After treatment with albuterol, there was a small, but statistically significant, decrease in number of ventilation defects (mean, 9.6-8.0 defects; P = .025). After DNase and chest physical therapy, there was a trend toward increasing ventilation defects (mean, 8.3 defects; P = .096), but with a residual net improvement relative to baseline. CONCLUSION: In patients with CF, HHe MR ventilation defects correlate with spirometry, change with treatment, and are elevated in number in patients with CF with normal spirometry results. Thus, HHe MR appears to possess many of the characteristics required of a biomarker for pulmonary CF and may be useful in the evaluation of CF pulmonary disease severity or progression.

Administration, Inhalation↗

Detection of age-dependent changes in healthy adult lungs with diffusion-weighted 3He MRI.

RATIONALE AND OBJECTIVES: To investigate changes in lung microstructure in healthy adult subjects with no smoking history using diffusion-weighted 3He MRI. MATERIALS AND METHODS: Diffusion magnetic resonance imaging using hyperpolarized helium 3 (3He) was applied to healthy volunteers to explore the dependence of lung microstructural changes with age, reflected by changes in the apparent diffusion coefficient (ADC) of 3He in lung air spaces. Data from three sites (University of Virginia (UVa), N = 25; University of Wisconsin (UW), N = 8; University of Nottingham (UN), N = 11) were combined in pooled analysis, including a total of N = 44 subjects (age range, 18-69 years; average age, 41.7 +/- 16.7 years). RESULTS: ADC was found to depend on age at all three sites (UW, R = +0.95, P = .0003; UVa, R = +0.74, P < .0001; UN, R = +0.96, P < .0001). Increases in mean ADCs with age appeared similar across sites (UW, +0.0017 cm2 s(-1) y(-1); UVa, +0.0015 cm2 s(-1) y(-1); pooled, +0.0015 cm2 s(-1) y(-1); P = .71). In a regional analysis performed on UW data, the increase in ADC affected all regions of the lung, but the apical and middle regions showed a greater increase compared with the base of the lung. CONCLUSION: Results suggest the observed age dependence of the ADC may be caused by changes in lung microstructure that increase alveolar volume during the aging process.

Adolescent↗

Pulmonary embolism: comprehensive evaluation with MR ventilation and perfusion scanning with hyperpolarized helium-3, arterial spin tagging, and contrast-enhanced MRA.

PURPOSE: Development of a comprehensive magnetic resonance (MR) examination consisting of MR angiography (MRA) and MR ventilation and perfusion (MR V/Q) scan for the detection of pulmonary emboli (PE) and assessment of the technique in a rabbit model. MATERIALS AND METHODS: Reversible PE was induced by inflating a non-detachable silicon balloon in the left pulmonary artery of five New Zealand White rabbits. MR V/Q scans were obtained prior to, during, and after balloon deflation. MRA was performed during balloon inflation. MR ventilation imaging was performed after the inhalation of hyperpolarized helium-3. MR perfusion imaging was performed with Flow-sensitive Alternating Inversion Recovery with an Extra Radiofrequency pulse technique (FAIRER). High-resolution contrast-enhanced MR pulmonary angiography was used to confirm the occlusion of the pulmonary artery. All imaging was performed on a 1.5-T whole body scanner with broadband capabilities. RESULTS: High-resolution ventilation images of the lungs were obtained. No ventilation defects were detected before, during, or after resolution of simulated PE. FAIRER imaging allowed visualization of pulmonary perfusion. No perfusion defects were detected prior to balloon inflation. During balloon inflation (PE), there was decreased perfusion in the left lower lobe. After reversal of the PE, there was improved perfusion to the left lower lobe. In analogy to nuclear medicine techniques, acute PE produced a mismatched defect in the MR V/Q scan. MRA verified the occlusive filling defect in the left pulmonary artery. CONCLUSION: High-resolution MRA and MR V/Q imaging of the lung is feasible and allows comprehensive assessment of pulmonary embolism in one imaging session.

Animals↗

Ventilation imaging of the lung: comparison of hyperpolarized helium-3 MR imaging with Xe-133 scintigraphy.

RATIONALE AND OBJECTIVES: To compare hyperpolarized helium-3 (HHe) magnetic resonance imaging (MRI) of the lung with standard Xe-133 lung ventilation scintigraphy. MATERIALS AND METHODS: We performed a retrospective review of 15 subjects who underwent HHe MRI and Xe-133 lung ventilation imaging. Coronal MRI sections were acquired after a single inhalation of HHe gas, and standard posterior planar lung ventilation scintigraphy was performed during continuous breathing of Xe-133 gas. The first breath scintigram of each patient was compared with a composite MR image composed of the sum of the individual MR images and with the individual helium-3 MR images. Ventilation defects on the two imaging modalities were compared for size, conspicuity, and concordance in presence and location. Assessment was done separately for each of four lung quadrants. RESULTS: Comparing the composite HHe MR images with Xe-133 scintigraphy, ventilation defect size, conspicuity and concordance were the same in 67% (40/60), 63% (38/60), and 62% (37/60) quadrants, respectively. Comparing the individual HHe MR image sections with the Xe-133 ventilation scan, there was concordance between the ventilation defects in 27% (16/60) of quadrants. More defects were identified on the individual HHe MR images in 62% (37/60) of quadrants. CONCLUSION: There was good agreement between composite HHe MR image and first breath Xe-133 scintigraphic images, supporting the widely held assumption that HHe MRI likely depicts first breath lung ventilation.

Adolescent↗

A novel technique for localization and excisional biopsy of small or ill-defined pulmonary lesions.

BACKGROUND: The purpose of this study was to develop and evaluate radiotracer-guided localization of small or ill-defined pulmonary nodules for thoracoscopic excisional biopsy. METHODS: This study consisted of two parts: a laboratory study in rats to determine the most suitable radiotracer, and a pilot study in humans to determine the feasibility of radiotracer lung nodule localization. The right lung of 12 rats was injected with a technetium 99m (Tc 99m) based radiotracer solution: 4 each with macroaggregated albumin (MAA), unfiltered sulfur colloid (SC), and pertechnetate (TcO(4)). Serial imaging was performed using a small animal gamma camera for 4 hours following injection. In 13 patients, computed tomographic (CT) guided injection of Tc 99m MAA solution was made into or adjacent to a pulmonary nodule suspicious for primary lung cancer. Gamma probe localization of the nodule was performed during subsequent thoracoscopic surgery. RESULTS: In the animal model, MAA provided more precise localization than SC or TcO(4) and was selected for the human study. In the human series, all 13 patients had successful gamma probe localization of their lesion. There were no radiologic or surgical complications. Seven of 13 nodules were malignant, and five of these nodules were stage IA primary lung carcinomas. CONCLUSIONS: Computed tomographic-guided radiotracer localization of small or ill-defined pulmonary nodules using Tc 99 m MAA before thoracoscopic excisional biopsy is feasible and may make excisional biopsy the preferred management strategy for the management of small pulmonary nodules in patients at high risk for malignancy.

Aged↗

Hyperpolarized gas MR imaging of the lung.

Hyperpolarized gases belong to a new class of MR contrast agents that, when inhaled, provide high temporal and spatial resolution images of the lung airspaces. At this time, hyperpolarized gas MRI is only being performed at a limited number of institutions. However, the availability of hyperpolarized gas MRI could increase dramatically in coming years as regulatory hurdles within the U.S. are surmounted. The intent of this paper is to provide an introduction to hyperpolarized gas MRI for the thoracic radiologist. It includes a description of the basic principles of hyperpolarized gas MRI and a review of the results of preliminary clinical investigations with this method.

Asthma↗

Rapid hyperpolarized 3He diffusion MRI of healthy and emphysematous human lungs using an optimized interleaved-spiral pulse sequence.

PURPOSE: To develop and validate an interleaved-spiral diffusion pulse sequence capable of hyperpolarized (3)He MR imaging of the whole lung in less than 10 seconds. MATERIALS AND METHODS: Hyperpolarized (3)He diffusion measurements were performed in seven healthy volunteers and five patients with emphysema using an interleaved-spiral pulse sequence that provided 11 contiguous 15-mm thick coronal ADC maps, with an in-plane resolution of 3.9 mm, covering the whole lung in 5.5 seconds. The resulting means and SDs of ADC values were compared statistically to those from a gradient-echo pulse sequence with identical resolution and diffusion-weighting gradients that acquired five ADC maps in 10.5 seconds. RESULTS: High-quality diffusion-weighted interleaved-spiral images covering the whole lung were obtained, and showed no significant susceptibility-induced image degradation compared to corresponding gradient-echo images. On a subject-by-subject basis, the means and SDs of ADC values for the interleaved-spiral technique were not statistically different from those for the gradient-echo technique. The mean ADC values from the two techniques were highly correlated on a section-by-section basis (R = 0.99). CONCLUSION: The interleaved-spiral diffusion pulse sequence permits rapid acquisition of contiguous ADC maps covering the whole lung during a short breath-hold period, and provides ADC values that are statistically equivalent to those from standard gradient-echo techniques.

Adult↗

Applications of hyperpolarized helium-3 gas magnetic resonance imaging in pediatric lung disease.

Hyperpolarized gas magnetic resonance imaging (MRI) of the lung provides high temporal and spatial resolution images of the air spaces of the lung and can be used to elucidate both lung ventilation and morphology. Because no ionizing radiation is involved, hyperpolarized gas MRI is ideal for the evaluation of pediatric lung diseases. In the article, we describe briefly the basic principles of hyperpolarized gas MRI, review the literature of hyperpolarized gas MRI in two pediatric lung diseases (asthma and cystic fibrosis), and discuss possible future clinical applications of hyperpolarized gas imaging in pediatric lung disease.

Asthma↗

MRI of the lungs using hyperpolarized noble gases.

The nuclear spin polarization of the noble gas isotopes (3)He and (129)Xe can be increased using optical pumping methods by four to five orders of magnitude. This extraordinary gain in polarization translates directly into a gain in signal strength for MRI. The new technology of hyperpolarized (HP) gas MRI holds enormous potential for enhancing sensitivity and contrast in pulmonary imaging. This review outlines the physics underlying the optical pumping process, imaging strategies coping with the nonequilibrium polarization, and effects of the alveolar microstructure on relaxation and diffusion of the noble gases. It presents recent progress in HP gas MRI and applications ranging from MR microscopy of airspaces to imaging pulmonary function in patients and suggests potential directions for future developments.

Animals↗

Emphysema: hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes--initial experience.

PURPOSE: To quantitatively evaluate hyperpolarized helium 3 ((3)He) diffusion magnetic resonance (MR) images of the lung in patients with emphysema and to determine whether apparent diffusion coefficients (ADCs) measured with MR imaging correlate with spirometric indexes. MATERIALS AND METHODS: Hyperpolarized (3)He diffusion MR imaging was performed in 16 healthy volunteers and 11 patients. Coronal diffusion-sensitized MR images were obtained during suspended respiration after inhalation of laser-polarized (3)He gas, and images of the ADC were calculated. Spirometry was performed immediately before imaging. The mean and SD of the ADCs were compared between subject groups and were correlated with spirometric indexes. RESULTS: ADC images were homogeneous in volunteers, but demonstrated regional variations in patients. The mean and SD of the ADCs for patients were significantly larger (P <.002) than those for volunteers. The mean ADCs for all subjects correlated with the percentage of predicted forced expiratory volume in 1 second, or FEV(1), (r = -0.797, P <.001) and the ratio of FEV(1) to forced vital capacity, or FVC, (r = -0.930, P <.001). ADC images in patients demonstrated a significant increase (P <.001) in the ADCs in the upper regions compared with the lower regions of the lung. CONCLUSION: Hyperpolarized (3)He diffusion MR imaging demonstrated potential for use in evaluating the global and regional severity of emphysema.

Adult↗