PubMed Health⌕ Search

Biomedical subjects

Tamás Jávorfi

Publications and source records attributed to Tamás Jávorfi.

3 recordsLinked to original sources

Comparative study of integrating cavity absorption meters.

Integrating spheres (IS) are widely used for recording spectra of scattering samples by placing the specimen inside or outside the sphere. An unusual application of integrating spheres has been also demonstrated earlier where the liquid sample completely filled the spherical cavity; such a device is often called an integrating cavity absorption meter (ICAM). In the present work, integrating cavities with different coatings are compared. The spheres were made of glass, covered by metal or white paint, and their surfaces were prepared for diffuse or specular reflectance. The spheres were evaluated by recording kinetic traces following a short light pulse with the aid of time-correlated single photon counting (TCSPC), and by recording steady-state spectra through single-photon counting (SPC) detection. The relative efficiencies of the spheres were determined by comparing the steady-state spectra. Possible reasons for differences in the performance are discussed.

Absorption↗

Singlet oxygen quenching by thione analogues of canthaxanthin, echinenone and rhodoxanthin.

Thione analogues of three naturally occurring carotenones (canthaxanthin, echinenone, and rhodoxanthin) were synthesized just over ten years ago, and it was reported that substitution of the oxygen atom by sulphur brings about a large red shift and some broadening in the optical absorption spectrum of the compound. Since the three carotenothiones are scarce, determination of their molar absorption coefficients presents a challenge. A method for relating the molar absorption coefficient of a carotenothione (Car-S) to that of its ketone analogue (Car-O) has been developed, which has revealed that the peak molar absorption coefficient of a Car-S is only about 60% of the corresponding value for Car-O. Using methylene blue as the sensitizer and acetonitrile as the solvent, we have also investigated the quenching (under photostationary conditions) of the 1270nm phosphorescence emission of singlet oxygen by each of the six carotenoids. The data conform to the Stern-Volmer relation, and show that substitution of a carbonyl oxygen atom by sulphur does not lead to an appreciable change in the value of the quenching constant, which is close to 1.5 x 10(10)M(-1)s(-1) for all six quenchers.

Canthaxanthin↗

Quantitative spectrophotometry using integrating cavities.

Absorption spectrophotometry, a standard tool for quantitative analysis, suffers from two major drawbacks: lack of sensitivity and vulnerability to scattering. It has been pointed out earlier that the solution to these problems lies in using a reflecting cavity as a sample holder. Due to multiple reflections at the cavity wall, the effective pathlength becomes considerably larger than the diameter of the cavity, and scattering losses are eliminated because scattered light is prevented from escaping the detector. Though much effort has been spent in analysing and improving the performance of such a device, often called an integrating cavity absorption meter (ICAM), a simple strategy for deducing the absorbance of the sample is still lacking. It is shown here that the absorbance A' measured by using an ICAM exhibits a sublinear increase with the solute concentration C. The physical reason for this departure from linearity is explained, and a straightforward procedure for converting A' to the true absorbance A (proportional to C) is established. The reliability of the procedure is demonstrated by comparing the ICAM absorption spectrum of dilute dye solutions with the spectra of more concentrated solutions recorded in a conventional spectrophotometer. The ability of the device to cope with scattering was tested by filling the ICAM with a suspension of chloroplasts, and the spectrum was found, as expected, to be free from scattering artefacts.

Calibration↗