PubMed Health⌕ Search

Biomedical subjects

Tamer Büyükyilmaz

Publications and source records attributed to Tamer Büyükyilmaz.

5 recordsLinked to original sources

Degree of conversion of two lingual retainer adhesives cured with different light sources.

The aim of this study was to evaluate the degree of conversion (DC) of two lingual retainer adhesives, Transbond Lingual Retainer (TLR) and Light Cure Retainer (LCR), cured with a fast halogen light, a plasma arc light and a light-emitting diode (LED) at various curing times. A conventional halogen light served as the control. One hundred adhesive samples (five per group) were cured for 5, 10 or 15 seconds with an Optilux 501 (fast halogen light), for 3, 6 or 9 seconds with a Power Pac (plasma arc light), or for 10, 20 or 40 seconds with an Elipar Freelight (LED). Samples cured for 40 seconds with the conventional halogen lamp were used as the controls. Absorbance peaks were recorded using Fourier transform infrared (FT-IR) spectroscopy. DC values were calculated. Data were analysed using Kruskal-Wallis and Mann-Whitney U-tests. For the TLR, the highest DC values were achieved in 6 and 9 seconds with the plasma arc light. Curing with the fast halogen light for 15 seconds and with the LED for 40 seconds produced statistically similar DC values, but these were lower than those with the plasma arc light. All of these light exposures yielded a statistically significantly higher DC than 40 seconds of conventional halogen light curing. The highest DC value for the LCR was achieved in 15 seconds with the fast halogen light, then the plasma arc light curing for 6 seconds. These two combinations produced a statistically significantly higher DC when compared with the 40 seconds of conventional halogen light curing. The lowest DC for the LCR was achieved with 10 seconds of LED curing. The overall DC of the LCR was significantly higher than that of the TLR. The results suggest that a similar or higher DC than the control values could be achieved in 6-9 seconds by plasma arc curing, in 10-15 seconds by fast halogen curing or in 20 seconds by LED curing.

Adhesives↗

Effect of light-emitting diode on bond strength of orthodontic brackets.

The aim of this study was to evaluate the effect of light-emitting diode (LED) light curing on shear bond strength (SBS) of orthodontic brackets bonded to teeth. Light exposure of 40 seconds from a conventional halogen-based light-curing unit was used as a control. Eighty human premolars were divided into four groups of 20 each. Brackets were bonded to acid-etched teeth with Transbond XT light-cured adhesive. In the first group, the adhesive was light cured for 40 seconds with a conventional halogen unit (XL3000, 3M). In the other three groups, adhesive was cured with a commercial LED unit (Elipar FreeLight, 3M ESPE) for 10, 20, or 40 seconds. SBS of brackets was measured on a universal testing machine and recorded in megapascals. Adhesive remnant index (ARI) scores were determined after failure of brackets. Data were analyzed using analysis of variance and chi-square tests. No statistically significant differences were found among the SBS values of halogen-based light-cured (13.1 +/- 3.1 MPa) and 20- and 40-second LED-cured (13.9 +/- 4.8 MPa and 12.7 +/- 5.1 MPa) specimens (P > .05). However, 10 seconds of LED curing yielded significantly lower SBS (P < .05). No statistically significant differences were found between the ARI scores among groups. The results of this study are promising for the orthodontic application of LED-curing units, but further compatibility and physical characteristic studies of various orthodontic adhesives and clinical trials should be performed before validation.

Dental Bonding↗

Intraosseous screw-supported upper molar distalization.

The aims of the present study were to investigate (1) the efficiency of intraosseous screws for anchorage in maxillary molar distalization and (2) the sagittal and vertical skeletal, dental, and soft tissue changes after maxillary molar distalization using intraosseous screw-supported anchorage. Twenty-five subjects (18 girls and seven boys; 11.3 to 16.5 years of age) with skeletal Class I, dental Class II malocclusion participated in the study. An anchorage unit was prepared for molar distalization by placing an intraosseous screw behind the incisive canal at a safe distance from the midpalatal suture following the palatal anatomy. The screws were placed and immediately loaded to distalize upper first molars or the second molars when they were present. The average distalization time to achieve an overcorrected Class I molar relationship was 4.6 months. The skeletal and dental changes were measured on cephalograms and dental casts obtained before and after the distalization. In the cephalograms, the upper first molars were tipped 8.8 degrees and moved 3.9 mm distally on average. On the dental casts, the mean distalization was five mm. The upper molars were rotated distopalatally. Mild protrusion (mean 0.5 mm) of the upper central incisors was also recorded. However, there was no change in overjet, overbite, or mandibular plane angle measurements. In conclusion, immediately loaded intraosseous screw-supported anchorage unit was successful in achieving sufficient molar distalization without major anchorage loss.

Adolescent↗

A practical method of fabricating a lingual retainer.

Retention is a major part of orthodontic treatment, not an optional secondary protocol. In recent years, studies investigating dentofacial changes during and after the growth period have led most clinicians to use fixed retention appliances after treatment. Fixed retainers can be attached to the teeth directly or indirectly. We present a practical, indirect method for bonding fixed retainers, using Sondhi Rapid-set Indirect Bonding Adhesive (3M Unitek, Monrovia, Calif).

Dental Bonding↗

Effects of fast halogen and plasma arc curing lights on the surface hardness of orthodontic adhesives for lingual retainers.

The aims of this study were to (1) identify the optimum cure times of 2 different lingual retainer adhesives with a conventional halogen, a fast halogen, and a plasma arc light by measuring Vickers surface hardness, and (2) determine whether different lights produce similar surface hardness values for the same adhesive resin material. The investigated plasma arc curing unit was the PowerPac (American Dental Technologies, Corpus Christi, Tex), and the fast halogen unit was the Optilux 501 (Kerr, Orange, Calif). A conventional curing unit, the Ortholux XT (3M Dental Products, St. Paul, Minn) was used as the control. Two orthodontic lingual retainer adhesives were used: Transbond Lingual Retainer (3M Unitek, Monrovia, Calif) and Light Cure Retainer (Reliance Orthodontic Products, Itasca, Ill). Concise (3M Dental Products) and diluted Concise were used as controls. Transbond Lingual Retainer was polymerized by the PowerPac light in 6 seconds, by the Optilux in 10 seconds, and by the conventional halogen light in 20 seconds. The minimum curing times for Light Cure Retainer adhesive were 15 seconds for PowerPac, 10 seconds for Optilux, and 40 seconds for conventional halogen. Surface hardness values for each resin did not differ significantly with different curing units. However, different adhesives demonstrated significantly different surface hardness values. Final Vickers surface hardness values (averaged across curing units) of Transbond Lingual Retainer, Concise, diluted Concise, and Light Cure Retainer were 62.8, 52.4, 46.0, and 40.4, respectively. Plasma arc or fast halogen units polymerize resin composite adhesive in much shorter times than do conventional curing units, without a significant loss in surface hardness. Therefore, these units are suggested for clinical use to save chairside time.

Adhesives↗