In-depth study of the electromagnetics of ultrahigh-field MRI.

In this work, numerical and experimental studies of the transverse electromagnetic (TEM) resonator modes at ultrahigh-field (UHF) MRI are performed using an in-house finite difference time domain package at 340 MHz and using an 8 T whole-body MRI system. The simulations utilized anatomically detailed human head mesh and a spherical head-sized phantom, while the experiments included an electromagnetically equivalent (to simulations) phantom and in vivo human head studies. An in-depth look at the homogeneity of the transmit-and-receive fields and local and global polarization of the electromagnetic waves inside the cavity of the head coil, and also the current distribution obtained on the resonator elements, is provided for several coil modes when the coil is empty and loaded. Based on the numerical and experimental results, which are in excellent agreement, an electromagnetic characterization of loading radio-frequency (RF) head coils during a UHF MRI experiment is provided. The possibility of using the aforementioned modes for specific types of imaging application is briefly reviewed.

Electromagnetic Fields↗

Evaluation of MRI RF probes utilizing infrared sensors.

The magnetic resonance imaging (MRI) coil's radio frequency (RF) field distribution has a strong effect on image quality as well as specific absorption rate. In this paper, a method of probing a coil's RF field distribution over any unoccupied region of the coil is presented. This technique is based on the use of infrared sensing. The proposed method was implemented and tested on a high field RF volume coil operating at 340 MHz. Very good agreement was achieved between the infrared measurements and numerical data obtained utilizing an in-house three-dimensional finite-difference time-domain package. The results demonstrate that the proposed technique is practical, robust, and efficient in making accurate measurements of the electric field distributions in loaded and unloaded MRI coils.

Equipment Design↗

Ultrahigh-field MRI whole-slice and localized RF field excitations using the same RF transmit array.

In this paper, a multiport driving mechanism is numerically implemented at ultra high-field (UHF) magnetic resonance imaging (MRI) to provide 1) homogenous whole-slice (axial, sagittal, or coronal) and 2) highly localized radio frequency (RF) field excitation within the same slices, all with the same RF transmit array (here chosen to be a standard transverse electromagnetic (TEM) resonator/coil). The method is numerically tested using a full-wave model of a TEM coil loaded with a high-resolution/18-tissue/anatomically detailed human head mesh. The proposed approach is solely based on electromagnetic and phased array antenna theories. The results demonstrate that both homogenous whole-slice as well as localized RF excitation can be achieved within any slice of the head at 7 T (298 MHz for proton imaging).

Algorithms↗

Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla.

In this work experimental and numerical studies of the MR signal were performed at frequencies ranging from 64 MHz to 485 MHz, utilizing three different MRI coils: a single-strut transverse electromagnetic (TEM)-based coil, a TEM resonator, and a high-pass birdcage coil. The experimental analyses were conducted using 1.5 and 8 Tesla whole-body systems and volume RF head coils. The simulation data were obtained utilizing an in-house-developed finite difference time domain (FDTD) model. Pertinent data from the numerical and experimental setups were compared, and a remarkable agreement between the two methods was found that clearly demonstrates the effectiveness of the FDTD method when it is applied rigorously. The numerical and experimental studies demonstrate the complexity of the electromagnetic (EM) fields and their role in the MR signal. These studies also reveal unique similarities and differences between the transmit and receive field distributions at various field strengths. Finally, for ultra high-field operations, it was demonstrated mathematically, numerically, and experimentally that highly asymmetric inhomogeneous images can be acquired even for linear excitation, symmetrical load geometries, and symmetrical load positioning within the coil.

Electromagnetic Fields↗

Analytical approach to the MR signal.

In this work, an analytical evaluation of the MR signal is presented using the principle of reciprocity for any transmit and receive probe(s) with general geometrical structure(s). It is shown that the excitation of the spins cannot be explained using the principle of reciprocity in its standard form due to the asymmetry in the permeability tensor of the transverse magnetization. In the reception problem, the standard form of the principle of reciprocity is then utilized to calculate the NMR signal. As expected, the analysis shows that the strength of the NMR signal is a function of the receive coil's (fictitious) circularly polarized component of the field that poses an opposite sense of rotation to that corresponding with the excitation field, produced by the same coil, if it were to be used for excitation.

Magnetic Resonance Imaging↗

Effects of coil dimensions and field polarization on RF heating inside a head phantom.

Deterioration of radiofrequency (RF) inhomogeneity with increasing static magnetic field in magnetic resonance imaging (MRI) is one of the fundamental challenges preventing their clinical rendition and posing safety hazards. Variation in RF coil designs could help redistribute RF energy absorption over the imaged object. This work is intended to determine experimentally the difference in RF heating produced within a human head phantom by in situ measurement of RF inhomogeneity as a function of coil design utilized at 8 T. The heating patterns of 1/4 wavelength (long) and 1/8 wavelength 11-cm (short) transverse electromagnetic (TEM) coils loaded with a homogeneous human head phantom at 340 MHz were evaluated. In addition, different transmit/receive (T/R) configurations were used in search for the possibility of "hot-spot" formation. Fluoroptic thermometry was used to measure temperatures in multiple positions in a head phantom made of ground turkey breast for RF powers corresponding to a specific absorption rate (SAR) of 4.0 W/kg for 10 min. Numerical simulations were performed to study the general RF power deposition patterns in phantoms at 340 MHz including the effects of field polarization. The temperature increases varied from 0 to 0.8 degrees C for the long RF coil, while the short RF coil produced a maximum temperature change of 0.5 degrees C. Similar to ultra high-field electromagnetic simulations, these measurements revealed low peripheral and high deep-tissue heating at 8 T. The findings indicated that the largest temperature changes for both cases were less than 1 degrees C. While these results showed an increase in localized heating due to RF pulses at 8 T, they highlight that RF inhomogeneity could be redistributed using different RF coil designs through which the hot spots could be made cooler.

Equipment Safety↗

Design and performance issues of RF coils utilized in ultra high field MRI: experimental and numerical evaluations.

In this paper, two TEM resonators were evaluated experimentally and numerically at 8 tesla (T) (340 MHz for 1H imaging). The coils were constructed to be 21.2-cm long (standard) and 11-cm long (a proposed less claustrophobic design). The experimental evaluation was done on a single cadaver using an ultra high field, 8 T, whole-body magnet. The numerical modeling was performed using an in-house finite difference time domain packagethat treats the coil and the load (anatomically detailed human head model) as a single system. The coils were tested with quadrature excitation at different coil alignment positions with respect to human head. For head imaging at 8 T, the overall numerical and experimental results demonstrated that when compared to the longer coil, the shorter coil provides superior signal-to-noise ratio, coil sensitivity, and excite field in the biological regions that lie within both of the coils' structures. A study of the RF (excite/receive fields) homogeneity showed variations in the performance of both coils that are mostly dependant on the region of interest and the position of coil with respect to the head. As such, depending on the application, the shorter coil could be effectively utilized.

Brain↗