PubMed Health⌕ Search

Biomedical subjects

Tanja Drosch

Publications and source records attributed to Tanja Drosch.

4 recordsLinked to original sources

Coronary artery bypass grafts: assessment of graft patency and native coronary artery lesions using 16-slice MDCT.

The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction.

Angina Pectoris↗

Non-invasive evaluation of coronary artery bypass grafts using 16-row multi-slice computed tomography with 188 ms temporal resolution.

BACKGROUND: Cardiac multi-slice computed tomography (MSCT) scanners permit visualization of the coronary arteries and coronary artery bypass grafts. The latest MSCT generation with true 16-detector slices (Sensation 16 Speed 4 D, Siemens, Forchheim, Germany) provides improved temporal and spatial resolution, as well as significantly reduced scan time. To assess, whether this technical improvement has also an impact on image quality and accuracy of MSCT diagnosis in patients with previous coronary artery bypass graft (CABG) surgery the following study was conducted. METHODS AND MATERIAL: Thirteen consecutive patients (pts) (10 male, 3 female, mean age 62 +/- 6.4 [55-73] years, heart rate 68 +/- 11 [52-88] bpm) and a total number of 43 coronary bypass grafts (11 arterial, 32 venous grafts) were examined by MSCT (gantry rotation time 375 ms). In addition to the analysis of coronary bypass grafts, 13 coronary segments (sgts) were evaluated in each patient (n = 169 sgts). MSCT results were compared with coronary angiography. RESULTS: Forty-one of 43 bypass grafts (95%) were analyzable by MSCT. In conventional angiography 16 of 43 (37%) grafts were occluded. Sixteen of them were correctly diagnosed by MSCT (sensitivity 100%). One graft showed a 50% anastomosis stenosis which was also detected. Twenty-five of 27 grafts without severe lesion showed no significant stenosis in MSCT (specificity 93%, positive predictive value (PPV) 89%, negative predictive value (NPV) 100%). Ninety of 108 (83%) high-grade stenosis (>70%) of the native coronary vessels were correctly detected (sensitivity 83%, PPV 78%). From the 61 sgts without high grade stenosis 36 were correctly classified (specificity 59%, NPV 67%). If sgts number 8, 9 and 10, which are normally not target for revascularization, are excluded sensitivity rises to 89%, specificity to 71%, PPV to 87% and NPV to 75%. The correct clinical diagnosis (absence or presence of a high grade stenosis of at least one bypass graft) was achieved in all patients. CONCLUSIONS: True 16-slice MSCT with faster gantry rotation time allows detection of lesions in coronary artery bypass grafts with high sensitivity and specificity. The evaluation of native vessels in pts with known CAD remains a diagnostic challenge. However, the correct clinical diagnosis was achieved in all pts. MSCT is a non-invasive tool to assess coronary artery bypass grafts.

Aged↗

Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution.

OBJECTIVES: The aim of our study was to evaluate the diagnostic accuracy of 16-multi-detector spiral computed tomography (MDCT) with 188 ms temporal resolution. BACKGROUND: Because of rapid technical innovations, MDCT coronary imaging has significantly improved in the last five years. Recent results indicate a high diagnostic accuracy, especially in patients with clinical suspicion of coronary artery disease (CAD). METHODS: A total of 72 consecutive patients (30 women, 42 men, age 64 +/- 10 years) scheduled for invasive coronary angiography (ICA) because of suspected CAD were additionally studied by MDCT (Sensation 16 Speed 4D, Siemens, Forchheim, Germany). Thirty-seven of 72 patients (51%) received an additional beta-blockade before MDCT because of heart rates >65 beats/min. The MDCT scans were analyzed regarding the presence of coronary artery lesions. Results were compared with ICA. RESULTS: All 72 scans showed diagnostic image quality (heart rate: 64.1 +/- 9.2 beats/min, calcium mass: 86 +/- 156 mg). Thirteen coronary segments were evaluated in each patient. Sixty-two of 936 (6.6%) segments showed a nondiagnostic image quality. All segments were included in the analysis. A total of 117 relevant lesions (diameter stenosis >50%) were detected using ICA, and 96 of 117 (82%) were detected by MDCT. Sensitivity, specificity, and positive and negative predictive values for the whole study group were as follows: 82%, 98%, 87%, and 97%, respectively. The correct clinical diagnosis of presence or absence of significant CAD was obtained in 65 of 72 (90%) patients. All stenoses were detected by MDCT in 52 of 72 (72%) patients. CONCLUSIONS: Our results indicate a high diagnostic accuracy of 16-slice MDCT with improved temporal resolution.

Adult↗

Coronary vessel visualization using true 16-row multi-slice computed tomography technology.

BACKGROUND: Multi-slice computed tomography (MSCT) scanners with retrospective ECG-gating permit visualization of the coronary arteries. Limited spatial and temporal resolution as well as breathing artefacts due to the scan time can cause poor distal vessel segment and side branch visualization. The latest MSCT generation with true 16-detector slices (Sensation 16), Siemens, Forchheim, Germany) provides furthermore improved temporal and spatial resolution, as well as significantly reduced scan time. To assess, whether this technical improvement has also an impact on image quality we conducted the following study. METHODS AND MATERIAL: Sixty-two consecutive patients (33 male, 29 female, mean age 63+/-8 [47-79] years, heart rate after beta-blockade 63+/-7 [45-86] bpm) with suspicion of coronary artery disease (CAD) were examined by cardiac MSCT. Parameter settings were: 0.75 mm collimation, 2.8mm table feed/rotation, caudocranial scan direction, 80 cc contrast media biphasic injection protocol, gantry rotation time 375 ms, temporal resolution 188 ms). Thirteen coronary segments (sgts) were evaluated in each patient (total number: 806 sgts). Image quality of each segment was determined as: excellent--free of motion artefacts, good--mild motion artefacts, relevant artefacts--still diagnostic value, severe calcification and insufficient image quality--not visualized segment. RESULTS: 301/806 (37%) sgts showed excellent and 294/806 (36%) sgts good image quality. Relevant artefacts were seen in 107/806 (13%) sgts, calcifications in 41/806 (5%) sgts. 63/806 (8%) sgts could not be visualized (34 of them (54%) either segment 9 or 10). Diagnostic image quality was achieved in 702/806 (87%) sgts. CONCLUSIONS: Due to true 16-slice technology and faster gantry rotation time MSCT image quality could be improved and allows a visualization of the entire coronary tree. Larger, randomized, catheter-controlled studies have to be conducted to determine, whether this improved visualization also translates into better diagnostic accuracy.

Aged↗