PubMed Health⌕ Search

Biomedical subjects

Tara Rosewall

Publications and source records attributed to Tara Rosewall.

3 recordsLinked to original sources

A magnetic resonance imaging study of prostate deformation relative to implanted gold fiducial markers.

PURPOSE: To describe prostate deformation during radiotherapy and determine the margins required to account for prostate deformation after setup to intraprostatic fiducial markers (FM). METHODS AND MATERIALS: Twenty-five patients with T1c-T2c prostate cancer had three gold FMs implanted. The patients presented with a full bladder and empty rectum for two axial magnetic resonance imaging (MRI) scans using a gradient recalled echo (GRE) sequence capable of imaging the FMs. The MRIs were done at the time of radiotherapy (RT) planning and a randomly assigned fraction. A single observer contoured the prostate surfaces. They were entered into a finite element model and aligned using the centroid of the three FMs. RESULTS: During RT, the prostate volume decreased by 0.5%/fraction (p = 0.03) and the FMs in-migrated by 0.05 mm/fraction (p < 0.05). Prostate deformation was unrelated to differential bladder and bowel filling, but was related to a transurethral resection of the prostate (TURP) (p = 0.003). The standard deviation for systematic uncertainty of prostate surface contouring was 0.8 mm and for FM centroid localization was 0.4 mm. The standard deviation of random interfraction prostate deformation was 1.5 mm and for FM centroid variability was 1.1 mm. These uncertainties from prostate deformation can be incorporated into a margin recipe to determine the total margins required for RT. CONCLUSIONS: During RT, the prostate exhibited: volume decrease, deformation, and in-migration of FMs. Patients with TURPs were prone to prostate deformation.

Aged↗

Efficient on-line setup correction strategies using plan-intent functions.

With the introduction of image-guided radiation therapy (IGRT) delivery systems on-line set-up correction strategies have gained in popularity. Usually, the correction workload of these strategies is high compared to off-line strategies as daily setup corrections have to be performed based on a predefined action level. In this work, it is proposed that on-line strategies must not only be judged in terms of workload but also in terms of efficacy. While workload can be easily predicted for such strategies, the efficacy must ultimately reflect the efficiency with which the original treatment plan intent is met. The purpose of this work is to investigate the tradeoff between workload and efficacy of three different on-line set-up correction strategies: The common fixed action level strategy and two novel on-line setup correction strategies, i.e., a dose-volume histogram (DVH) constraint and an equivalent uniform dose (EUD) score strategy that aim directly for better compliance with original treatment plan intent. All strategies were reformulated in terms of a score function that reflected treatment plan intent. A retrospective study was conducted on 5 prostate patients (7-field conformal, 79.8 Gy, 42 fractions). PTV margins were 10 mm except in the posterior direction (7 mm). The original treatment plan intent for these patients was defined using a set of DVH constraints. The results show that the on-line setup correction strategy based on a fixed action level of 3 mm resulted in a considerable correction workload. For larger action levels, a dose benefit (in terms of EUD) in the rectum and bladder was observed for all patients which is clinically "fortuitous" but difficult to take advantage of. In contrast, the application of the two novel strategies generally resulted in a controlled decrease of the dose to the rectum and the bladder with a smaller workload. It is concluded that using information about target anatomy and the planned dose distribution allows the design of specific correction strategies that are better tailored to the individual patient and that comply effectively with initial treatment plan intent.

Artifacts↗

A phase II study of localized prostate cancer treated to 75.6 Gy with 3D conformal radiotherapy.

BACKGROUND AND PURPOSE: To prospectively evaluate toxicity, biochemical failure-free survival (bFFS) and biopsy-proven local control for prostate cancer patients treated with 75.6 Gy in 42 fractions using 6-field conformal radiotherapy to prostate alone. PATIENTS AND METHODS: From 1997 to 1999, 140 patients with T1-2NxM0, Gleason score or=grade 2: 2%, and GU>or=grade 2: 1%. The 3-year bFFS of patients failure-free before biopsy was 93% (95% CI: 83-100) from a negative biopsy and 22% (95% CI: 0-56) from a positive biopsy (P=0.001). Patients reported significantly more late toxicity than physicians (GI: P=0.003, GU: P<0.001). At 5.0 years median follow-up, cause-specific survival was 98% (95% CI: 96-100), overall survival was 91% (95% CI: 86-97), and bFFS was 55% (95% CI: 45-64). CONCLUSIONS: 75.6 Gy caused modest levels of acute and late toxicity. Three-year biopsies predicted subsequent biochemical outcome.

Adenocarcinoma↗