Irregularities on the surface of single-piece AcrySof SA60AT intraocular lenses.

PURPOSE: To report a case series of what initially appeared to be macroscopic biomaterial deposits and irregularities on the surface of AcrySof SA60AT intraocular lenses (IOLs) (Alcon Inc.) SETTING: Department of Ophthalmology and Somerset Hospital, Taunton, United Kingdom; Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, Utah, USA; and Intraocular Implant Unit, Sydney Eye Hospital, University of Sydney, Sydney, Australia. METHODS: Twelve AcrySof SA60AT IOLs were initially thought to have irregularities on their surfaces when examined under the operating microscope before implantation in the capsular bag during cataract surgery. The IOLs were sent for further analysis, including gross examination and light and scanning electron microscopy, to John A. Moran Eye Center, Salt Lake City, Utah, USA, and to Alcon Laboratories, Hemel Hempstead, United Kingdom. RESULTS: Light microscopy revealed the presence of irregular fine lesions on the IOLs' optics and haptics. The lesions consisted of elevations and depressions of the IOL surface that were present on both the anterior and the posterior surfaces of the IOLs. Scanning electron microscopy confirmed the presence of physical/mechanical damage to the IOLs, which was thought to originate from the packaging. The manufacturer believed this to have resulted from compression of the IOL between the container and its cover. CONCLUSIONS: Implantation of an imperfect IOL remains a potentially serious occurrence. Faults still occur in modern IOLs, and some defects can be detected by examining the IOL under the operating microscope before implantation into the eye.

Acrylic Resins↗

Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer.

PURPOSE: To assess the effects of central corneal thickness (CCT) and corneal curvature (CC) on the measurements of intraocular pressure (IOP) using Goldmann applanation tonometer (GAT) and the ocular blood flow pneumatonometer (OBFT). METHODS: 104 patients were recruited from a glaucoma clinic. The CCT was measured using ultrasound pachymetry and the mean radius of CC using a keratometer. The IOP of each eye was measured using both GAT and the OBFT in a random order. Right eyes only were analysed for statistical purposes. RESULTS: The mean (+/-SD) IOP by GAT and OBFT was 18.2 mmHg (+/-4.4) and 18.2 mmHg (+/-4.0), respectively, with no statistically significant difference. IOP measurement with both instruments varied with CCT and CC. GAT showed an IOP increase of 0.40 mmHg per 10 microm increase of CCT and OBFT showed an increase of 0.38 mmHg in IOP per 10 microm increase of CCT. Multiple regression analysis showed that the effect of CCT was statistically significant (P<0.001) on IOP recorded by both the GAT and OBFT but CC did not have a statistically significant effect on IOP recordings performed by either technique. CONCLUSION: IOP measurements by GAT and OBFT are positively correlated with CCT with both tonometers being similarly affected. There was no significant correlation between CC and IOP measured by either tonometer.

Adult↗

Suprachoroidal hemorrhage during cataract surgery in a vitrectomized eye.

We report a case of surprachoroidal hemorrhage (SCH) that occurred during cataract surgery in a previously vitrectomized eye. The only sign of SCH was a progressive shadow obscuring the red reflex. There was no increase in intraocular pressure (IOP), shallowing of the anterior chamber, or iris prolapse. Postoperatively, the SCH gradually resolved without complications, leaving a series of subretinal pigmentary lines. Surgeons should be aware that the signs normally expected in SCH may not develop in vitrectomized eyes. Obscuration of the red reflex may be the only sign of the hemorrhage, and when this happens, it may be prudent to keep the IOP elevated and suture the incision at the end of the procedure.

Aged↗