PubMed Health⌕ Search

Biomedical subjects

Tatiana Fleck

Publications and source records attributed to Tatiana Fleck.

4 recordsLinked to original sources

The incidence of reoperations in pacemaker recipients.

OBJECTIVE: To evaluate the incidence of reoperation due to complications or battery depletion in patients who underwent endocardial permanent pacemaker implantation during an 8-year period. METHODS: All pacemaker implantation and related procedures from January 1996 to June 2003 were retrospectively collected and entered into a database. During this time period a total number of 3856 operations with 2242 primary implantations and 1614 redo operations were performed at our department. As 809 patients were referred from another hospital, where the primary operation was done, these patients were excluded from further analysis. The mean follow-up time was 48 months, ranging from 6 to 96 months. RESULTS: A total of 547 patients underwent 805 reoperations during this 8-year period. The most common cause for reoperation was lead malfunction, which occurred in 326 patients (8.4%). Atrial leads were affected more commonly (206 patients, 63%) than ventricular leads (120 patients, 37%). Eighty percent of lead failure occurred during the first 3 months after implantation and was due to dislocation of the lead, whereas the remaining 20% occurred more than 3 months after implantation and were caused by lead fracture, insulation failure, and exit block. Elective replacement indication of a pacemaker was necessary in 312 patients (8%), and pacemaker pocket erosion or infection required reoperation in 167 patients (4%). CONCLUSION: Permanent pacemaker implantation is now accepted as a highly effective and safe procedure. However, cost effectiveness and the relatively simple procedure have to be weighed against the need of reoperations due to system malfunction or replacement indication.

Aged↗

Total endoscopic CABG using robotics on beating heart.

BACKGROUND: The implementation of a total endoscopic coronary surgery on the beating heart with the aid of the Da Vinci surgical system (Intuitive, Sunnyvale, CA) requires a stepwise learning process. After cadaveric training and clinical start of the program in November 2002, we gained experience with arrested heart procedures starting in May 2003. In November 2003, we moved to beating heart surgery. METHODS: From November 2003 to January 2005, 14 patients with coronary artery disease (mean age of 62 +/- 5 years, female to male ratio 2:12) were operated with the intention to perform a beating heart TECAB (totally endoscopic coronary artery bypass grafting) procedure. RESULTS: Total conversion rate was 35% (5/14), due to pleural adhesions in 2 patients, injury of the lung during port placement, inability to occlude the LAD with saddle loops, atherosclerotic diseased mammary artery in 1 patient each. Mean operating time was 298 +/- 110 minutes with a steady decline throughout the study period (first 5 patients: 342 +/- 61 minutes, patients 6 to 9: 337 +/- 87 minutes, last 4 patients: 290 +/- 53 minutes), resulting in a 60 minute shorter operating time. Mean ICU stay was 1.3 days and hospital stay lasted on average 8.4 +/- 2.8 days. CONCLUSION: Total endoscopic bypass surgery on the beating heart with the Da Vinci surgical system can be safely implemented in clinical use. The learning curve results in a constantly decreasing procedure time due to a more effective table team-console surgeon-robotic system interaction and a moderate conversion rate.

Coronary Artery Bypass, Off-Pump↗

Complicated acute aortic dissection type B caused by femoral cannulation for endoscopic coronary artery bypass surgery.

PURPOSE: To report endovascular treatment of a patient with complicated acute aortic type B dissection caused by cannulation of the femoral artery for endoscopic coronary artery bypass (CAB) surgery. CASE REPORT: A 63-year-old man underwent single-vessel CAB surgery facilitated by the Da Vinci surgical system. After the procedure, acute lower limb ischemia led to the discovery of a type B dissection from the left subclavian artery to the iliac arteries. The subclavian artery was also dissected, with only minimal flow in the left mammary artery. The visceral and renal vessels originated from the false lumen and were not perfused. Emergent stent-graft placement was undertaken to close the entry tear and re-establish perfusion of the lower extremity as well as visceral and renal organs. Additional stent-grafts were placed in the dissected left subclavian artery to perfuse the left internal mammary bypass and in the inferior mesenteric artery, which arose from the false lumen. Six months after operation, the patient is well. CONCLUSIONS: Acute iatrogenic aortic dissection secondary to endoscopic CAB surgery can be treated emergently to restore distal perfusion to vital organs.

Aneurysm↗