PubMed Health⌕ Search

Biomedical subjects

Tatsuaki Tsukamoto

Publications and source records attributed to Tatsuaki Tsukamoto.

7 recordsLinked to original sources

Hepatic metastases: diffusion-weighted sensitivity-encoding versus SPIO-enhanced MR imaging.

PURPOSE: To retrospectively compare accuracy of diffusion-weighted (DW) single-shot echo-planar imaging with sensitivity encoding (SENSE) with that of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging in the evaluation of hepatic metastases due to extrahepatic malignancies. MATERIALS AND METHODS: Patients provided informed consent; ethics committee approval was not required. The data of 24 patients (16 men, eight women; age range, 41-68 years; mean age, 61.9 years) with 40 resected hepatic metastases were retrospectively reviewed. Before SPIO administration, DW SENSE imaging and T2-weighted fast spin-echo (SE) and T1-weighted dual-echo fast field-echo (FFE) MR imaging were performed. After SPIO administration, T2-weighted fast SE, T1-weighted dual-echo, and T2*-weighted FFE MR examinations were performed. Images were divided into two sets: The SPIO-enhanced MR image set consisted of pre- and postcontrast T2-weighted fast SE and dual-echo T1-weighted FFE images and postcontrast T2*-weighted FFE images. The DW SENSE image set included DW SENSE images and precontrast T2-weighted fast SE and dual-echo T1-weighted FFE images. Three radiologists individually interpreted these images and sorted the confidence levels for presence of hepatic metastasis in each section into five grades. Area under the receiver operating characteristic (ROC) curve (A(z)) was calculated for each image set. RESULTS: Hepatic metastases showed higher signal intensity on DW SENSE images than on T2-weighted fast SE images. Conversely, signals from vessels and cysts were suppressed with DW SENSE imaging. ROC analysis showed higher A(z) values when the DW SENSE image set was interpreted (0.90) than when the SPIO-enhanced MR image set was interpreted (0.81). The sensitivity and specificity, respectively, of total cases were 0.66 and 0.90, for the SPIO-enhanced MR image set and 0.82 and 0.94 for the DW SENSE image set. During SPIO-enhanced MR image interpretation, lesions 1 cm in diameter or smaller showed significantly lower sensitivity than lesions larger than 1 cm in diameter. During both interpretation sessions, left lobe lesions showed significantly lower sensitivity than right lobe lesions. CONCLUSION: Combined reading of DW SENSE images and T2-weighted fast SE and dual-echo T1-weighted FFE MR images showed higher accuracy in the detection of hepatic metastases than did reading of SPIO-enhanced MR images.

Adult↗

MDCT of pancreatic adenocarcinoma: optimal imaging phases and multiplanar reformatted imaging.

OBJECTIVE: The objective of our study was to evaluate the individual contributions of arterial, pancreatic parenchymal, and portal venous phase (PVP) images and the utility of coronal and sagittal multiplanar reformatted (MPR) images in the assessment of pancreatic adenocarcinoma using triple-phase MDCT. MATERIALS AND METHODS: Thirty-one patients with and 35 patients without pancreatic adenocarcinoma underwent triple-phase MDCT. Three radiologists independently attempted to detect pancreatic adenocarcinoma and assess local extension using the MDCT images in five sessions. The first three sessions involved sets of images obtained in arterial phase, pancreatic parenchymal phase, and PVP separately and respectively. In the fourth session, a combination of axial images from all phases was evaluated. During the fifth session, radiologists had access to coronal and sagittal MPR images together with the axial images obtained in all phases. Results were compared with surgical findings using receiver operating characteristic (ROC) analysis and kappa statistics. RESULTS: Regarding tumor detection, the image set composed of coronal and sagittal MPR images and of axial images obtained in all phases had a significantly higher value for the area under the ROC curve (A(Z), 0.98 +/- 0.01) than the other image sets and yielded the highest sensitivity (93.5%). The sensitivity of the arterial phase image set (80.6%) was significantly lower than that of all other image sets. Whereas the image set composed of coronal and sagittal MPR images and axial images obtained in all phases yielded the highest kappa values for all local extension factors evaluated, the image set composed of only arterial phase images yielded the lowest kappa values for almost all of the factors. CONCLUSION: A combination of pancreatic parenchymal phase and PVP imaging is necessary and efficient for the assessment of pancreatic adenocarcinoma. The addition of coronal and sagittal MPR images increased the performance of MDCT, especially in the evaluation of local extension.

Adenocarcinoma↗

[Improving diffusion-weighted imaging of liver with SENSE technique: a preliminary study].

Diffusion-weighted imaging (DWI) has not commonly been performed for assessment of the liver because of technical and physiologic problems. The sensitivity-encoding (SENSE) technique enables the acquisition time to be shortened and reduces artifacts on DWI. We compared the DWI without SENSE, with SENSE only, and with SENSE and half-Fourier technique using a 1.5 Tesla MRI unit. In general, imaging quality was improved and fewer artifacts were observed in DWI with SENSE. DWI of liver with SENSE is expected to be a useful tool for clinical application.

Aged↗

A case with primary amyloidosis of the liver and spleen: radiologic findings.

A case with primary amyloidosis of the liver and spleen is presented. In the liver, ultrasonography showed heterogeneous echogenicity. Portal phase CT showed heterogeneous enhancement, and delayed phase CT showed delayed enhancement with focal hypoattenuating areas. Bone scintigraphy showed diffuse accumulation. In the spleen, arterial phase CT showed the lack of parenchymal enhancement, and T2-weighted MR imaging showed decreased signal intensity. The combination of imaging findings of the liver and spleen was suggestive of amyloidosis.

Aged↗

Hypervascular hepatocellular carcinoma: can double arterial phase imaging with multidetector CT improve tumor depiction in the cirrhotic liver?

OBJECTIVE: We assessed the efficacy of double arterial phase CT with multidetector CT for the detection of hypervascular hepatocellular carcinoma in the cirrhotic liver. MATERIALS AND METHODS: Double arterial phase images with multidetector CT were evaluated using quantitative, qualitative, and receiver operating characteristic analyses for 59 patients with 78 hepatocellular carcinomas. Early and late arterial phase (double arterial phase) CT scans were obtained at a fixed time of 25 and 40 sec, respectively, after administration of contrast material. Total dose and injection rate of contrast material were 100 mL and 3 mL/sec, respectively. RESULTS: On the basis of the receiver operating characteristic curves, the mean area under the curve values of the late (0.98) and combined arterial phase CT scans (0.98) were equivalent, and both were significantly greater than the mean of the early arterial phase CT scans (0.842) for detecting hepatocellular carcinoma (p < 0.05). The mean relative sensitivity values obtained with the late (69/78, 88%) and combined arterial phase CT scans (70/78, 90%) were also equivalent and were significantly greater than those obtained with the early arterial phase CT scans (52/78, 67%; p < 0.001). CONCLUSION: Double arterial phase CT with multidetector CT showed no significant improvement in effectiveness compared with single late arterial phase CT used alone for detecting hypervascular hepatocellular carcinoma in the cirrhotic liver.

Adult↗

A case of aorto-bronchial fistula after insertion of left main bronchial self-expanding metallic stent in a patient with recurrent esophageal cancer.

We report a case of aorto-bronchial fistula (ABF) caused by a self expanding metallic stent (EMS) 51 days after insertion into the left main bronchus. The patient presented with left main bronchial stenosis caused by post-operative local recurrence of esophageal cancer. Post-operative radio therapy totaling 40 Gy and post-recurrence radiotherapy totaling 34 Gy were administered, with daily fractions of 2 Gy. Stenosis of the left main bronchus improved slightly, and was followed with insertion of EMS to prevent restenosis. The patient experienced massive hemoptysis for 3 days before sudden death. Autopsy revealed the EMS edge perforating the descending aortic lumen. Tumor infiltration and bacterial infection were observed on the wall of the left bronchus, and atherosclerosis was present on the aortic wall around the fistula. It should be noted that the left main bronchus was at considerable risk of ABF after insertion of EMS for malignant stenosis, and prophylactic sent insertion into the left bronchus without imperative need must be avoided.

Aged↗

Pancreatic adenocarcinoma: MDCT versus MRI in the detection and assessment of locoregional extension.

PURPOSE: To compare dynamic-contrast enhanced multirow detector computed tomography (MDCT) including multiplanar reformatted images (MPR) and magnetic resonance imaging (MRI) including magnetic resonance cholangiopancreatography images for the detection and assessment of locoregional extension of pancreatic adenocarcinoma. MATERIALS AND METHODS: Twenty-four patients with and 21 patients without pancreatic adenocarcinoma underwent triple-phase MDCT and MRI. Three radiologists independently attempted to detect pancreatic adenocarcinoma and assess locoregional extension in 3 sessions. First session involved MDCT images. In the second session, radiologists had access to coronal and sagittal MPR images together with the axial images (MDCT + MPR). Third session involved MR images. Results were compared with surgical findings using receiver operating characteristic analysis and kappa statistics. RESULTS: Regarding tumor detection, MDCT + MPR had a significantly higher value for areas under the curve (0.96 +/- 0.02) at receiver operating characteristic analysis compared with those of MRI (0.90 +/- 0.03) and MDCT (0.85 +/- 0.04). MDCT + MPR had the highest mean sensitivity (96%), and MRI had the highest mean specificity (98%). For locoregional extension, MDCT + MPR showed the highest kappa values of the study for all factors evaluated (range, 0.63-0.86). CONCLUSIONS: In conclusion, multiphasic MDCT imaging with MPR images was superior to multiphasic MDCT imaging without MPR images and to comprehensive MRI employing 2-D sequences and magnetic resonance cholangiopancreatography for both the detection and assessment of locoregional extension of pancreatic adenocarcinomas. MRI might be used for further lesion characterization regarding its high specificity.

Adenocarcinoma↗