PubMed Health⌕ Search

Biomedical subjects

Terence M Peters

Publications and source records attributed to Terence M Peters.

2 recordsLinked to original sources

Novel multistage three-dimensional medical image segmentation: methodology and validation.

In this paper, we propose a novel multistage method for three-dimensional (3-D) segmentation of medical images and a new radial distance-based segmentation validation approach. For the 3-D segmentation method, we first employ a morphological recursive erosion operation to reduce the connectivity between the region of interest and its surrounding neighborhood; then we design a hybrid segmentation method to achieve an initial result. The hybrid approach integrates an improved fast marching method and a morphological reconstruction algorithm. Finally, a morphological recursive dilation is employed to recover any lost structure from the first stage of the multistage method. This approach is tested on 12 CT and 3 MRI images of the brain, heart, and kidney, to demonstrate the effectiveness and accuracy of this technique across a variety of imaging modalities and organ systems. In order to validate the multistage segmentation method, a novel radial distance-based validation method is proposed that uses a global accuracy (GA) measure. The GA is calculated based on local radial distance errors (LRDE), where LRDE are calculated on the radii emitted from points along the skeleton of the object rather than the centroid, in order to accommodate more complicated organ structures. The experimental results demonstrate that the proposed multistage segmentation method is fast and accurate, with comparable performance to existing segmentation methods, but with a significantly higher execution speed.

Algorithms↗

Automatic fusion of freehand endoscopic brain images to three-dimensional surfaces: creating stereoscopic panoramas.

A major limitation of the use of endoscopes in minimally invasive surgery is the lack of relative context between the endoscope and its surroundings. The purpose of this work was to fuse images obtained from a tracked endoscope to surfaces derived from three-dimensional (3-D) preoperative magnetic resonance or computed tomography (CT) data, for assistance in surgical planning, training and guidance. We extracted polygonal surfaces from preoperative CT images of a standard brain phantom and digitized endoscopic video images from a tracked neuro-endoscope. The optical properties of the endoscope were characterized using a simple calibration procedure. Registration of the phantom (physical space) and CT images (preoperative image space) was accomplished using fiducial markers that could be identified both on the phantom and within the images. The endoscopic images were corrected for radial lens distortion and then mapped onto the extracted surfaces via a two-dimensional 2-D to 3-D mapping algorithm. The optical tracker has an accuracy of about 0.3 mm at its centroid, which allows the endoscope tip to be localized to within 1.0 mm. The mapping operation allows multiple endoscopic images to be "painted" onto the 3-D brain surfaces, as they are acquired, in the correct anatomical position. This allows panoramic and stereoscopic visualization, as well as navigation of the 3-D surface, painted with multiple endoscopic views, from arbitrary perspectives.

Algorithms↗