PubMed Health⌕ Search

Biomedical subjects

Teresa Gallo

Publications and source records attributed to Teresa Gallo.

3 recordsLinked to original sources

Equatorially connected diruthenium(II,III) units toward paramagnetic supramolecular structures with singular magnetic properties.

The reaction of Ru2Cl(O2CMe)(DPhF)3 (DPhF = N,N'-diphenylformamidinate) with mono- and polycarboxylic acids gives a clean substitution of the acetate ligand, leading to the formation of complexes Ru2Cl(O2CC6H5)(DPhF)3 (1), Ru2Cl(O2CC6H4-p-CN)(DPhF)3 (2), [Ru2Cl(DPhF)3(H2O)]2(O2C)2 (3), [Ru2Cl(DPhF)3]2[C6H4-p-(CO2)2] (4), and [Ru2Cl(DPhF)3]3[C6H3-1,3,5-(CO2)3] (5). The preparation of [Ru2(NCS)(DPhF)3]3[C6H3-1,3,5-(CO2)3] (6) and {[Ru2(DPhF)3(H2O)]3[C6H3-1,3,5-(CO2)3]}(SO3CF3)3 (7) from 5 is also described. All complexes are characterized by elemental analysis, IR and electronic spectroscopy, mass spectrometry, cyclic voltammetry, and variable-temperature magnetic measurements. The crystal structure determinations of complexes 2.0.5THF and 3.THF.4H2O (THF = tetrahydrofuran) are reported. The reactions carried out demonstrate the high chemical stability of the fragment [Ru2(DPhF)3]2+, which is preserved in all tested experimental conditions. The stability of this fragment is also corroborated by the mass spectra. Electrochemical measurements reveal in all complexes one redox process due to the equilibrium Ru2(5+) <--> Ru2(6+). In the polynuclear complex 7, some additional oxidation processes are also observed that have been ascribed to the presence of two types of dimetallic units rather than two consecutive reversible oxidations. The magnetic behavior toward temperature for complexes 1-7 from 300 to 2 K is analyzed. Complexes 1-7 show low values of antiferromagnetic coupling in accordance with the molecular nature in 1 and 2 and the absence of important antiferromagnetic interaction through the carboxylate bridging ligands in 3-7, respectively. In addition, the magnetic properties of complex 7 do not correspond to any magnetic behavior described for diruthenium(II,III) complexes. The experimental data of compound 7 are simulated considering a physical mixture of S = 1/2 and 3/2 spin states. This magnetic study demonstrates the high sensitivity of the electronic configuration of the unit [Ru2(DPhF)3]2+ to small changes in the nature of the axial ligands. Finally, the energy gap between the pi and delta orbitals in these types of compounds allows the tentative assignment of the transition pi --> delta.

Journal Article↗

Polyp measurement and size categorisation by CT colonography: effect of observer experience in a multi-centre setting.

The extent measurement error on CT colonography influences polyp categorisation according to established management guidelines is studied using twenty-eight observers of varying experience to classify polyps seen at CT colonography as either 'medium' (maximal diameter 6-9 mm) or 'large' (maximal diameter 10 mm or larger). Comparison was then made with the reference diameter obtained in each patient via colonoscopy. The Bland-Altman method was used to assess agreement between observer measurements and colonoscopy, and differences in measurement and categorisation was assessed using Kruskal-Wallis and Chi-squared test statistics respectively. Observer measurements on average underestimated the diameter of polyps when compared to the reference value, by approximately 2-3 mm, irrespective of observer experience. Ninety-five percent limits of agreement were relatively wide for all observer groups, and had sufficient span to encompass different size categories for polyps. There were 167 polyp observations and 135 (81%) were correctly categorised. Of the 32 observations that were miscategorised, 5 (16%) were overestimations and 27 (84%) were underestimations (i.e. large polyps misclassified as medium). Caution should be exercised for polyps whose colonographic diameter is below but close to the 1-cm boundary threshold in order to avoid potential miscategorisation of advanced adenomas.

Chi-Square Distribution↗

CT colonography interpretation times: effect of reader experience, fatigue, and scan findings in a multi-centre setting.

Our purpose was to assess the effect of reader experience, fatigue, and scan findings on interpretation time for CT colonography. Nine radiologists (experienced in CT colonography); nine radiologists and ten technicians (both groups trained using 50 validated examinations) read 40 cases (50% abnormal) under controlled conditions. Individual interpretation times for each case were recorded, and differences between groups determined. Multi-level linear regression was used to investigate effect of scan category (normal or abnormal) and observer fatigue on interpretation times. Experienced radiologists (mean time 10.9 min, SD 5.2) reported significantly faster than less experienced radiologists and technicians; odds ratios of reporting times 1.4 (CI 1.1, 1.8) and 1.6 (1.3, 2.0), respectively (P<or=0.001). Experienced and less-experienced radiologists took longer to report abnormal cases; ratio 1.2 (CI 1.1,1.4, P<0.001) and 1.2 (1.0, 1.3, P=0.03), respectively. All groups took 70% as long to report the final five cases as they did with an initial five; ratio 0.7 (CI 0.6 to 0.8), P<0.001. For technicians only, accuracy increased with longer reporting times (P=0.04). Experienced radiologists report faster than do less-experienced observers and proportionally spend less time interpreting normal cases. Technicians who report more slowly are more accurate. All groups reported faster as the study period progressed.

Clinical Competence↗