Least-mean-squares algorithm to determine submicrometer particle diameter, volume fraction, and size distribution width by elastic light scattering.

A computationally fast method to determine values and their uncertainty for particulate system volume median diameter, volume fraction, and size distribution width is presented. These properties cannot be obtained for submicrometer particulate by diffraction-based methods. The technique relies on a least-mean-squares method applied over a prespecified size range and distribution width. Prespecifying the range significantly reduces the number of calculations required to determine the particulate parameters from experimental data, allowing the practical evaluation of large data sets. The solution method that was developed has significant advantages over ratio-style calculations that are more commonly performed, the primary of which is a simple method to determine errors in the measurement parameters. We evaluated the predicted performance for a specific experimental system for various levels of noise, with monodisperse and log-normal distributions, by analyzing synthetic data with the algorithm. Results were a quantitative statement of system accuracy. In addition, synthetic log-normal data evaluated with monodisperse models revealed significant and systematic errors in the predicted volume median diameter. These errors indicate that, in general, systems with a significant size distribution width must be analyzed with a model that includes this size distribution. Finally, calibrated polystyrene spheres were measured with an experimental system that used four simultaneous scattering measurements, and all diameters were within the reported uncertainty.

Journal Article↗

Design methodology for a Fabry-Perot interferometer used as a concentration sensor.

We present the design methodology for a sensor that can nonintrusively monitor target gas concentration levels in a power plant exhaust flow. The measurement is based on radiative emission by rovibrational transitions that are well isolated from emission features of other constituents and requires both moderate spectral resolution (typically 1 nm or below) and relatively high optical throughput. A Fabry-Perot interferometer provides this capability, and its conceptual design is discussed at length. High-temperature radiative emission of nitric oxide in a background of water was used as a sample system for the design of a prototype Fabry-Perot interferometer. Predictions for the instrument are a minimum resolvable NO column density of 100 parts per million times meter based on a simple background subtraction scheme with a gas temperature of 800 K. Improved order sorting can dramatically lower this minimum. The prototype instrument was calibrated and tested with a laboratory simulator; results are presented and compared with predictions.

Journal Article↗