PubMed Health⌕ Search

Biomedical subjects

Tetsuro Oshika

Publications and source records attributed to Tetsuro Oshika.

At least 19 recordsLinked to original sources

Posterior capsule opacification after combined cataract surgery and vitrectomy.

PURPOSE: To compare the degree of posterior capsule opacification (PCO) after combined cataract surgery and vitrectomy and after cataract surgery alone in age-matched control patients and in patients with and without diabetes mellitus (DM). SETTING: Sugita Eye Hospital, Nagoya, Japan. METHOD: In a prospective study, patients were divided into 2 groups: those having cataract surgery alone (cataract group) and those having combined cataract and vitrectomy surgery (combined group). The 2 groups were further divided into patients without DM (non-DM subgroup) and patients with DM (DM subgroup). The PCO rates were determined 3, 6, and 12 months after surgery using the POCO system. RESULTS: In the cataract group, the non-DM subgroup and the DM subgroup each comprised 42 eyes of 42 patients. In the combined group, the non-DM subgroup comprised 26 eyes of 26 patients and the DM subgroup, 23 eyes of 23 patients. In the cataract group, the PCO rate in the DM subgroup was significantly higher than in the non-DM subgroup at every postoperative examination (P<.05). In the non-DM subgroup, the PCO rate was significantly higher at every postoperative examination in patients having combined surgery than in patients having cataract surgery alone (P<.05). In the combined group, the PCO rate did not differ significantly between the non-DM subgroup and the DM subgroup. CONCLUSION: Even patients without DM must be carefully monitored for PCO development after combined surgery.

Aged↗

Relationship of progression of visual field damage to postural changes in intraocular pressure in patients with normal-tension glaucoma.

PURPOSE: To evaluate whether postural changes of intraocular pressure (IOP) are associated with progression of visual field damage in patients with normal-tension glaucoma (NTG). DESIGN: Prospective, noncomparative, nonrandomized study. PARTICIPANTS: Sixty eyes of 33 patients with NTG. METHODS: Intraocular pressure, blood pressure (BP), and pulse rate (PR) were measured in both sitting and supine positions. Visual fields were examined using Humphrey Field Analyzer (HFA; Zeiss-Humphrey Instruments, Inc., San Leandro, CA). Changes in mean deviation (MD) per year (dB/year), that is, MD slope, were calculated by linear regression analysis of the HFA Statpac 2 program. MAIN OUTCOME MEASURES: The relationship between postural changes of IOP and MD slope was analyzed. The correlation between postural changes of IOP and cardiovascular parameters such as BP and PR also was analyzed. RESULTS: The IOP in the supine position was significantly higher than that in the sitting position (P<0.001, paired t test). There was no significant correlation between MD slope and sitting IOP (Pearson r = 0.172; P = 0.188), but a significant correlation was found between MD slope and supine IOP (r = -0.261; P = 0.043). The MD slope significantly correlated with IOP elevation caused by the postural change (r = -0.682; P<0.001). The systolic BP in the supine position correlated with postural changes of IOP (r = 0.364; P = 0.004), but other cardiovascular parameters did not correlate with IOP parameters. CONCLUSIONS: The progression of visual field damage in NTG is associated with IOP in the supine position and the magnitude of IOP elevation accompanying postural changes. These results suggest that deterioration in NTG may occur when patients are lying flat during sleep.

Aged↗

Incidence of intraoperative floppy iris syndrome in patients on either systemic or topical alpha(1)-adrenoceptor antagonist.

PURPOSE: To evaluate the incidence of Intraoperative Floppy Iris syndrome (IFIS) in relation to the usage of alpha(1)-adrenoceptor antagonists. DESIGN: Prospective, interventional case series. METHODS: In 2,643 consecutive eyes of 1,968 patients undergoing cataract surgery, occurrence of IFIS and use of alpha(1) antagonists were recorded. RESULTS: IFIS was observed in 29 eyes (1.1%) of 25 male patients, all of whom were receiving alpha(1) antagonists. In those receiving systemic tamsulosin, alpha(1A) selective antagonist, IFIS developed in 25 (43.1%) of 58 eyes. In those receiving systemic naftopidil, alpha(1A) and alpha(1D) antagonists, IFIS was found in 4 (19.0%) of 21 eyes. There was no case of IFIS in patients who received other systemic alpha(1) antagonists and in eyes treated with bunazosin eyedrops, a nonselective alpha(1) antagonist. CONCLUSIONS: IFIS occurred in 1.1% of cases treated with systemic alpha(1A)-adrenoceptor antagonists for benign prostatic hypertrophy. Topical nonselective alpha(1) antagonist did not induce IFIS.

Administration, Topical↗

Contrast sensitivity function and ocular higher-order wavefront aberrations in normal human eyes.

PURPOSE: To investigate the relation between contrast sensitivity function and ocular higher-order wavefront aberrations in normal human eyes. STUDY DESIGN: Prospective observational case series. PARTICIPANTS: Three hundred seven eyes of 161 normal subjects, ranging in age from 15 to 60 years (30.9+/-8.0 [mean +/- standard deviation]). METHODS: Ocular higher-order aberrations were measured for a 4-mm pupil using the Hartmann-Shack wavefront analyzer. The root-mean-square of the third- and fourth-order Zernike coefficients was used to represent comalike and spherical-like aberrations, respectively. We measured contrast sensitivity, low-contrast visual acuity (VA), and letter contrast sensitivity. From the contrast sensitivity data, the area under the log contrast sensitivity function (AULCSF) was calculated. Pupil diameter in a photopic condition was recorded using a digital camera. RESULTS: Multiple linear regression analysis revealed that comalike aberration (P = 0.002) was significantly associated with AULCSF, but spherical-like aberration (P = 0.200), age (P = 0.185), and photopic pupil diameter (P=0.252) were not. Comalike aberration showed a significant correlation with low-contrast VA (P<0.001), but spherical-like aberration (P = 0.293), age (P = 0.266), and pupil diameter (P = 0.756) did not. Comalike aberration was found to be significantly associated with letter contrast sensitivity (P<0.001), but spherical-like aberration (P=0.082), age (P = 0.370), and pupil diameter (P = 0.160) were not. CONCLUSIONS: In normal human eyes, comalike aberration of the eye significantly influences contrast sensitivity function.

Accommodation, Ocular↗

Inadvertent insertion of an opposite-power intraocular lens.

An 82-year-old woman with age-related cataract and high myopia had uneventful phacoemulsification and intraocular lens (IOL) implantation. Preoperative visual acuity was 20/60 with -16.00 -3.00 x 70 and axial length was 29.29 mm. An IOL (MA60MA, Alcon) of +5.0 diopters (D) was selected with target refraction of -1.5 D. The next day, visual acuity was 20/15 with +5.50 -2.00 x 60. It was found that an IOL of -5.0 D was inadvertently inserted instead of +5.0 D because of an identical package appearance of the opposite-diopter IOLs except for a small negative sign before the diopter label. The -5.0 D IOL was surgically replaced with +5.0 D IOL, and visual acuity became 20/15 with -0.50 -2.00 x 70. When selecting an IOL for highly myopic patients, attention should be paid to the extreme resemblance of the package of opposite-diopter IOLs.

Aged, 80 and over↗

Posterior capsule opacification after cataract surgery in patients with diabetes mellitus.

PURPOSE: To prospectively compare the degree of posterior capsule opacification (PCO) after cataract surgery in patients with and without diabetes mellitus. SETTING: Sugita Eye Hospital, Nagoya, Japan. METHODS: Forty-two eyes of 42 consecutive diabetes mellitus patients (DM group) and 42 eyes of 42 non-DM patients (control group) scheduled to have cataract surgery were enrolled. The PCO value was determined using the posterior capsule opacification (POCO) system 3, 6, and 12 months after surgery. RESULTS: Posterior capsule opacification values 3 months after surgery did not differ significantly between the 2 groups (P>.05). At 6 and 12 months, the PCO values of the DM group were significantly higher than those of the control group (P = .002 and P = .03, respectively). CONCLUSION: Diabetic patients had significantly more severe PCO after cataract surgery than nondiabetic patients.

Aged↗

Prospective intrapatient comparison of 6.0-millimeter optic single-piece and 3-piece hydrophobic acrylic foldable intraocular lenses.

PURPOSE: To compare postoperative performance and stability of 6.0-mm optic single- and 3-piece acrylic foldable intraocular lenses (IOLs). DESIGN: Prospective, randomized, self-controlled trial. PARTICIPANTS: Eighty eyes of 40 patients with bilateral senile cataracts. INTERVENTION: Phacoemulsification and IOL implantation were performed. One eye of a patient was randomly assigned to the SA60AT single-piece IOL, and the contralateral eye was allocated to the MA60AC 3-piece IOL. MAIN OUTCOME MEASURES: Best-corrected visual acuity (BCVA), spherical equivalent, aqueous flare intensity, anterior chamber depth, amount of IOL decentration and tilt, area of anterior capsule opening, and degree of posterior capsule opacification (PCO) were measured 2 days, 1 week, and 1, 3, 6, and 12 months after surgery. Specular microscopy was performed at 12 months postoperatively. RESULTS: In the SA60AT group, the anterior chamber depth did not show significant changes after surgery (P>0.05; paired t test), and the refraction remained highly stable throughout the 1-year study period. The MA60AC group showed significant shallowing of the anterior chamber (P<0.05) and a myopic shift (P<0.05) up to 1 month after surgery. There were no significant differences between the 2 groups (P>0.05) in BCVA, aqueous flare intensity, the amount of IOL decentration, IOL tilt, area of anterior capsule opening, and degree of PCO throughout the 12-month follow-up period. CONCLUSIONS: Both the SA60AT single-piece and MA60AC 3-piece lenses showed a minimum amount of decentration, tilt, anterior capsule contraction, and PCO. Although the MA60AC showed significant forward shift and myopic refractive changes after surgery, the SA60AT displayed little axial movement associated with highly stable refraction after surgery. This feature of the SA60AT should facilitate earlier spectacle prescription and quicker visual/social rehabilitation of patients after cataract surgery.

Acrylic Resins↗

An endothelin type A receptor antagonist reverses upregulated VEGF and ICAM-1 levels in streptozotocin-induced diabetic rat retina.

Diabetic retinopathy, a cause of blindness, is often associated with the upregulation of vascular endothelial growth factor (VEGF) in the retina. Recently, leukocyte adhesion (leukostasis) is claimed for the occlusion of retinal capillary vascularity, which ultimately assists in the progression of diabetic retinopathy. In addition, intercellular adhesion molecule-1 (ICAM-1), a representative factor for leukostasis, is increased in diabetic retina. Endothelin (ET)-1, a potent vasoconstrictor peptide, is closely linked to the pathogenesis of diabetic retinopathy. Different therapeutic interventions concerning VEGF have already been proposed to prevent diabetic retinopathy. However, no study has yet reported concerning the effects of ET-1 receptor antagonist on the upregulated VEGF and ICAM-1 in morphologically intact diabetic retina. The current study investigated the effect of ET(A) receptor antagonist (TA-0201; 1 mg kg(-1) day(-1)) on the expressions of VEGF and ICAM-1 in rat diabetic retina. Diabetes was induced by intraperitoneal injection of streptozotocin (70 mg/kg) in Sprague-Dawley rats, whereas control rats (Cont) received only citrate buffer. After 1 week, the streptozotocin-administered rats were randomly divided into two groups: ET(A) receptor antagonist-treated group (DM+TA-0201) and saline-treated group (DM+vehicle). After the treatment for 4 weeks, the retina was removed from the eyeball. In DM+vehicle group, the VEGF expression of retina was significantly increased (33.5 pg/mg) in comparison with that in the Cont group (25.1 pg/mg), and the upregulation of VEGF was reversed in DM+TA-0201 group (26.9 pg/mg), a phenomenon consistent with the change in VEGF mRNA levels. The expression of retinal ICAM-1 was increased in DM+vehicle group (55.1 pg/mg) compared with Cont group (43.8 pg/mg), and ET antagonism completely blocked this increase (43.8 pg/mg). Moreover, an increased leukostasis by 3.3-fold in DM+vehicle retina was returned to the control level by ET antagonism. In the current study, there was no obvious retinal morphological alteration from both the hematoxylin and eosin staining and the FITC-dextran angiography. Thus, ET(A) receptor antagonist might be useful in preventing the progression of diabetic retinopathy, as evidenced by suppressing the increase in VEGF and ICAM-1 levels as well as leukostasis in morphologically intact diabetic retina.

Animals↗

Optical quality of the cornea after overnight orthokeratology.

PURPOSE: To review changes in the optical quality of the cornea induced by overnight orthokeratology for myopia. METHODS: Sixty-four eyes of 39 patients who underwent overnight orthokeratology for myopia were prospectively examined. Inclusion criteria were uncorrected visual acuity of 20/20 or better after treatment and a minimum follow-up of 3 months. To quantitatively assess changes in corneal regular and irregular astigmatism, videokeratography data were decomposed into spherical component, regular astigmatism, asymmetry, and higher-order irregularity using Fourier analysis. In addition, corneal wavefront aberrations were calculated by expanding anterior corneal height data from videokeratography into a set of orthogonal Zernike polynomials. RESULTS: Although orthokeratology significantly reduced manifest refraction and improved uncorrected visual acuity, the asymmetry component, which is one of the features of irregular astigmatism, increased significantly from 0.35 +/- 0.22 to 0.64 +/- 0.40 D after treatment (P < 0.0001, paired t test). The increases in the asymmetry component significantly correlated with the amount of myopic correction (Pearson correlation coefficient, R = 0.40, P = 0.0009). Furthermore, the root-mean-square of third-order (coma-like) and fourth-order (spherical-like) aberrations significantly increased after orthokeratology (P < 0.0001, paired t test), and these increases showed significant positive correlations with the amount of myopic correction (Pearson correlation coefficient, R = 0.452, P = 0.0001 and R = 0.381, P = 0.0017, respectively). CONCLUSION: Corneal irregular astigmatism and higher-order aberrations significantly increased even in clinically successful orthokeratology, and the increases correlated with the magnitude of myopic correction. A large myopic correction by orthokeratology should be avoided to not decrease corneal optical quality.

Adolescent↗

Influence of pupil diameter on the relation between ocular higher-order aberration and contrast sensitivity after laser in situ keratomileusis.

PURPOSE: To investigate the influence of pupil diameter on the relation between induced changes in ocular higher-order wavefront aberrations and changes in contrast sensitivity by conventional laser in situ keratomileusis (LASIK) for myopia. METHODS: In 215 eyes of 117 patients (age, 33.2 +/- 8.3 years) undergoing LASIK for myopia of -1.25 to -13.5 D (-5.28 +/- 2.55 D), ocular wavefront aberrations and contrast sensitivity function were determined before and 1 month after surgery. Preoperative photopic pupil diameter was measured with a digital camera. Ocular higher-order aberrations were measured for a 4-mm pupil with a Hartmann-Shack wavefront analyzer. The root-mean-square (RMS) of the third- and fourth-order Zernike coefficients was used to represent coma- and spherical-like aberration, respectively. From the contrast-sensitivity data, the area under the log contrast sensitivity function (AULCSF) was calculated. RESULTS: One hundred five eyes had a photopic pupil diameter of 4 mm or larger, and the remaining 110 had a photopic pupil diameter smaller than 4 mm. There were no statistically significant differences in the background clinical data between these two groups. In the eyes with a photopic pupil diameter of 4 mm or larger, the changes in third-order comalike aberrations did not correlate with the changes in AULCSF (Pearson correlation coefficient, r = -0.037, P = 0.723) and 10% low-contrast visual acuity (r = 0.125, P = 0.224), but fourth-order spherical-like aberrations correlated significantly with the changes in AULCSF (r = -0.229, P = 0.024) and 10% low-contrast visual acuity (r = 0.221, P = 0.038). In the eyes with photopic pupil size smaller than 4 mm, there were significant correlations between the changes in comalike aberrations and the changes in AULCSF (r = -0.487, P < 0.001) and 10% low-contrast visual acuity (r = 0.310, P = 0.003), but spherical-like aberrations showed no correlation with the changes in AULCSF (r = -0.078, P = 0.485) and 10% low-contrast visual acuity (r = 0.208, P = 0.158). CONCLUSIONS: In eyes with larger photopic pupil diameter, increases in spherical-like aberration dominantly affect contrast sensitivity, whereas in eyes with smaller pupil size, changes in coma-like aberration exert greater influence on visual performance.

Adolescent↗

Optic disc and retinal nerve fiber layer analysis with scanning laser tomography after LASIK.

PURPOSE: To examine whether LASIK induces changes in the optic disc and retinal nerve fiber layer using scanning laser tomography. METHODS: Prospective, consecutive study of 53 myopic eyes in 38 patients (mean age: 35.7 +/- 10.4 years; range: 22 to 58 years). Preoperative average refractive error was -6.0 +/- 2.4 diopters (D) (spherical equivalent) (range: -2.0 to -10.0 D). Optic disc morphology and retinal nerve fiber layer thickness were evaluated with scanning laser tomography preoperatively and at 7 and 13 months postoperatively. RESULTS: No statistically significant differences were noted between the pre- and postoperative optic disc and retinal nerve fiber layer measurements. CONCLUSIONS: Our results suggest that transient extreme elevation of intraocular pressure during LASIK does not affect the optic disc morphology or retinal nerve fiber layer thickness in normal myopic eyes for at least 1 year after surgery.

Adult↗

A model of retinal ischemia-reperfusion injury in rats by subconjunctival injection of endothelin-1.

The retinal ischemia-reperfusion model is used in the study of transient ischemia-related diseases, such as central retinal artery occlusion, angle-closure glaucoma, and others. There are two methods for experimentally producing an ischemia-reperfusion model in the rat retina: (i) the intraocular pressure is greatly raised by increasing the height of the infusion bottle connected with the needle in the anterior chamber; or (ii) the blood vessel that accompanies the optic nerve in retina is ligated. However, each method has some drawbacks. For example, in the first method, the needle must be fixed in the anterior chamber for 1 hr, thus, the technique is not stable and mechanical damage to ocular structures sometimes occurs. In the second method, because of the unavoidable involvement of the optic nerve, damage to the nerve induces retinal changes unrelated to ischemia. In this study, we injected endothelin (ET)-1 under the conjunctiva of the eyeball (subconjunctival injection), and evaluated whether a retinal ischemia-reperfusion model could be generated by this method, simply and noninvasively. We injected 4 x 10(-5) M ET-1 solution into the right eye of the rat and injected a control vehicle (artificial tears) into the left eye. From 5-60 mins after the injection, 50 mg/ml fluorescein isothiocyanate (FITC)-dextran was injected to the left ventricle of heart. Then, the retina was removed and flat mounted. We compared the perfusion conditions of the FITC-dextran to each retina in the right and left eye. There was a complete perfusion of FITC-dextran in the retinal main artery, vein, and the capillary vessels in all of the control eyes. However, perfusion could not be completely observed in the ET-1 injected eye from 5-35 mins after injection; afterwards, the flow was returned. This method of subconjunctival injection of ET-1 is, thus, a feasible technical option for producing a retinal ischemia-reperfusion model in rat.

Animals↗

Ciliary body edema after scleral buckling surgery for rhegmatogenous retinal detachment.

PURPOSE: Choroidal detachment and anterior chamber (AC) shallowing develop in some cases after scleral buckling surgery for rhegmatogenous retinal detachment (RD). Postoperative angle-closure glaucoma has been reported to occur in 4% of cases. It is supposed that compression by the local scleral buckling induces ciliary body edema and angle narrowing. This study aimed to evaluate quantitatively the time course of changes in ciliary body thickness and AC depth (ACD) before and after the scleral buckling procedure using ultrasound biomicroscopy. DESIGN: Prospective consecutive case series. PARTICIPANTS: Forty-six eyes of 44 patients (43.7+/-18.1 years old [mean +/- standard deviation]) undergoing rhegmatogenous RD surgery. METHODS: Ciliary body thickness and ACD were measured before and 3, 7, 14, and 28 days after the procedure. Ultrasound biomicroscopy was used to evaluate ACD and ciliary body thickness. MAIN OUTCOME MEASURE: Time course of changes in ciliary body thickness and ACD. RESULTS: The surgery caused significant increases in ciliary body thickness at 3, 7, and 14 days postoperatively (P<0.0001, Bonferroni multiple comparison). Ciliary body edema reached its peak 3 days after surgery, followed by a gradual decrease thereafter. Ciliary body thickness in the encircling group was statistically greater than in the segmental buckling group at 3 and 7 days postoperatively (P<0.001, Student's t test). The ciliary body was significantly thicker in the direction of buckling than on the opposite side 3 days after surgery (P = 0.0079). In the encircling group, retinal reattachment surgery significantly decreased ACD 3 days after surgery (P = 0.018), whereas no significant fluctuations were found in the buckling group. CONCLUSIONS: Even without apparent choroidal detachment and a shallow AC, subclinical ciliary edema existed in all directions of all eyes for at least 1 month after the scleral buckling procedure. The ciliary body in the direction of scleral buckling showed greater edema than the other areas. Eyes treated with the encircling band showed greater ciliary edema than those treated with segmental buckling alone.

Adult↗

Psychometric properties of the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25), Japanese version.

BACKGROUND: The importance of evaluating the outcomes of health care from the standpoint of the patient is now widely recognized. The purpose of this study is to develop and test a Japanese version of the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). METHODS: A Japanese version was developed with a previously standardized method. The questionnaire and optional items were completed by 245 patients with cataracts, glaucoma, or age-related macular degeneration, by 110 others before and after cataract surgery, and by a reference group (n = 31). We computed rates of missing data, measured reproducibility and internal consistency reliability, and tested for convergent and discriminant validity, concurrent validity, known-groups validity, factor structure, and responsiveness to change. RESULTS: Based on information from the participants, some items were changed to 2-step items (asking if an activity was done, and if it was done, then asking how difficult it was). The near-vision and distance-vision subscales each had 1 item that was endorsed by very few participants, so these items were replaced with items that were optional in the English version. For example, more than 60% of participants did not drive, so the driving question was excluded. Reliability and validity were adequate for all subscales except driving, ocular pain, color vision, and peripheral vision. With cataract surgery, most scores improved by at least 20 points. CONCLUSION: With minor modifications from the English version, the Japanese NEI VFQ-25 can give reliable, valid, responsive data on vision-related quality of life, for group-level comparisons or for tracking therapeutic outcomes.

Adult↗

JNK inhibitory kinase is up-regulated in retinal ganglion cells after axotomy and enhances BimEL expression level in neuronal cells.

Optic nerve transection results in retinal ganglion cell (RGC) death in adult mammals, after the alteration of gene expression of RGCs. To elucidate the molecular mechanism by which axotomy induces RGC death, we isolated the molecules up-regulated after optic nerve transection. One of these, axotomy-related [corrected] gene (ARG)357, an 898-amino-acid [corrected] protein containing a complete serine-threonine kinase domain, was isolated from a subtraction library of the rat retina. The sequence showed that this gene was a rat homolog of human c-Jun N-terminal kinase (JNK) inhibitory kinase and so belonged to the germinal center kinase-VIII subfamily of Sterile20s protein kinase. We designated ARG357 as rat JNK inhibitory kinase (JIK). Rat JIK was expressed ubiquitously in various tissues and was highly expressed in the retina, with selective expression in RGCs. After axotomy, BimEL and Hrk, which are BH3-only proteins, and rat JIK were up-regulated in RGCs. Overexpression of rat JIK in neuronal cells up-regulated the expression of BimEL, but not that of Hrk. These results indicate that JIK may contribute to axotomy-induced RGC death by up-regulating the expression of BH3-only protein.

Adaptor Proteins, Signal Transducing↗

Immunohistochemical localization of advanced glycation end products in pinguecula.

BACKGROUND: Advanced glycation end products (AGEs) are known to be deposited in the target organ of ageing. In addition, the deposition of AGEs accelerate the process of ageing. We investigated the immunohistochemical localization of AGEs in pinguecula, one of the ocular changes related with ageing process. METHODS: Surgical specimens of conjunctiva with or without pinguecula were prepared from nine patients, respectively. Immunohistochemical localization of AGEs was investigated using monoclonal antibodies to N(epsilon)-(carboxymethyl)lysine, pentosidine, imidazolone, and pyrraline. RESULTS: Moderate to strong immunoreactivities to AGEs were detected in the subepithelial amorphous deposits of all the surgical specimens with pinguecula. In contrast, no or weak immunoreactivities to AGEs were detected in the surgical specimens without pinguecula. CONCLUSIONS: Pinguecula is an aggregation of AGEs-modified proteins. The presence of pinguecula would be an index of local irradiation of ultraviolet rays and decreased antioxidant activities.

Adult↗

Topical application of culture supernatant from human amniotic epithelial cells suppresses inflammatory reactions in cornea.

Human amniotic epithelial cells (HAEC) may be a source of soluble anti-inflammatory factors. The purpose of this study is to determine the effect of topically applied HAEC culture supernatant on corneal inflammatory reactions. HAEC were obtained from a placenta and cultured for 48 hr, and the supernatant was collected. The conditioned medium from HAEC contained small amounts of human interleukin-1 receptor antagonist (IL-1ra). Intrastromal sutures were placed in the cornea of BALB/c mice to induce corneal neovascularisation. Superficial cauterisation was applied to induce recruitment or activation of antigen presenting cells (APCs) in the cornea without neovascularisation. HAEC conditioned medium, placebo, or recombinant human IL-1ra was topically applied three times daily for 2 weeks. Suture-induced corneal neovascularisation was evaluated microscopically for 8 weeks. The cauterised corneas were harvested at 2 weeks, and the MHC class II(+) APCs were quantified by immunofluorescent staining and confocal microscopy. Inflammatory cytokine gene expression in the cauterised corneas was analyzed by a multiprobe ribonuclease protection assay. Conditioned medium from HAEC led to a profound suppression of corneal neovascularisation and fewer MHC class II(+) APCs in the epithelium. In contrast, human IL-1ra was only slightly effective in suppressing corneal inflammatory reactions. mRNA expression of murine IL-1ra and IL-1beta in the cauterised corneas was markedly suppressed after application of the conditioned medium. These results suggest that HAEC are a source of soluble anti-inflammatory factors and that conditioned medium from HAEC contains factors other than IL-1ra that suppress corneal inflammation.

Administration, Topical↗