PubMed Health⌕ Search

Biomedical subjects

Tetsuya Haruyama

Publications and source records attributed to Tetsuya Haruyama.

10 recordsLinked to original sources

Enzyme-based field-effect transistor for adenosine triphosphate (ATP) sensing.

Adenosine triphosphate (ATP) not only functions as an energy-carrier substance and an informative molecule, but also acts as a marker substance in studies of both bio-traces and cellular/tissular viability. Due to the importance of the ATP function for living organisms, in situ assays of ATP are in demand in various fields, e.g., hygiene. In the present study, we developed an ATP sensor that combines the selective catalytic activity of enzyme and the properties of an ion selective field effect transistor (ISFET). In this system, the ATP hydrolyrase, "apyrase (EC 3.6.1.5.)" is encased in a gel and mounted on a Ta(2)O(5) ISFET gate surface. When the enzyme layer selectively catalyzes the dephosphorylation of ATP, protons are accumulated at the gate because the enzymatic reaction produces H(+) as a byproduct. Based on the interfacial enzymatic reaction, the response from the ISFET is completely dependent upon the ATP concentration in the bulk solution. This device is readily applicable to practical in situ ATP measurement, e.g. hygienic usage.

Adenosine Triphosphate↗

Protein layer coating method on metal surface by electrochemical process through genetical introduced tag.

The technology of mercaptide self-assembly has previously been used to coat proteins onto metals, but is not practical for many surfaces. In this study, a short peptidic tag was employed for the electrochemical immobilization of proteins on metals (ECtag). A 6-mer histidine (alpha-amino-1H-imidazole-4-propionic acid) homopeptide was employed as an ECtag ligand, which forms coordinate bonds with Ni2+ and other divalent metal ions. Protein A was chosen as a model protein for the immobilization, and was genetically tagged with an ECtag for immobilization onto a Pt electrode surface through the reduction of ECtag:Ni2+ to ECtag:Ni by the electrode potential.

Adsorption↗

The construction of endothelial cellular biosensing system for the control of blood pressure drugs.

In order to assess blood pressure control drugs, the endothelial cellular biosensing system for assessing blood pressure control drugs was constructed. This system consists of human umbilical vein endothelial cells (HUVEC) on a polyion-coated gold electrode, a platinum counter electrode and an Ag/AgCl reference electrode. Nitric oxide (NO) as an indicator of blood vessel relaxation was detected with a polyion-coated electrode in the system. The NO detection limit of this electrode was 8.4 nM by differential pulse voltammetry (DPV). The drugs of blood pressure control (acetylcholine chloride (AcChCl), NOC 7 and NG-monomethyl-L-arginine (L-NMMA)) were assessed with this endothelial cellular biosensing system. One milli molar of AcChCl make NO released from HUVEC stimulated by activating endothelial nitric oxide synthase (eNOS) in HUVEC. In the case of 5 mM of L-NMMA, NO releasing was inhibited by inhibiting eNOS activation by 1 mM of AcChCl. NOC 7 immediately released NO regardless of eNOS activation in endothelial cells.

Antihypertensive Agents↗

Development of immune cellular biosensing system for assessing chemicals on inducible nitric oxide synthase signaling activator.

An immune cellular biosensing system has been constructed to assess immunomodulating effects of chemicals. Production of nitric oxide in the immune cellular biosensing system was used as readout of an immune cellular response for assessing the immunomodulating effects of chemicals. The macrophage-like cell line RAW264.7, which has signaling pathways of inducible nitric oxide synthase, was employed in the cellular biosensing system. The immune cellular biosensing system consisted of a Pt counter electrode, an Ag/AgCl reference electrode, and a gold electrode onto which a polyion complex layer was coated to allow adherence of the RAW264.7 cells. As the results of evaluating effects of a polyion complex layer on cell viabilities by using WST-8 assay, the polyion complex layer did not affect RAW264.7 cells. The polyion-coated gold electrode could measure NO without the drawback of electrochemical interference that occurs with differential pulse voltammetry. The detection limit of the immune cellular biosensing system was 4.2 nM released NO as measured by double potential step chronoamperometry. The potent immune activating abilities of lipopolysaccharide and interferon-gamma could be assessed by the cellular biosensing system; NO release from cells was detected within 600 ms.

Adjuvants, Immunologic↗

Micro- and nanobiotechnology for biosensing cellular responses.

Cells represent the minimum functional and integrating communicable unit of living systems. Cultured cells both transduce and transmit a variety of chemical and physical signals, i.e., production of specific substances and proteins, throughout their life cycle within specific tissues and organs. Such cellular responses might be usefully employed as parameters to obtain chemical information for both pharmaceutical and chemical safety, and drug efficacy profiles in vitro as a screening tool. However, such cellular signals are very weak and not easily detected with conventional analytical methods. By using micro- and nanobiotechnology methods integrated on-chip, a higher sensitivity and signal amplification has been developed for cellular biosensing. Micro- and nanotechnology is rapidly evolving to open new combinations of methods with improved technical performance, helping to resolve challenging bioanalytical problems including sensitivity, signal resolution and specificity by interfacing these technologies in small volumes in order to confirm specific cellular signals. Integration of cell signals in both rapid time and small space, and importantly, between different cell populations (communication and systems modeling) will permit many more valuable measurements of the dynamic aspects of cell responses to various chosen stimuli and their feedback. This represents the future for cell-based biosensing.

Animals↗

A biosensing system based on extracellular potential recording of ligand-gated ion channel function overexpressed in insect cells.

We have used outer cell potential measurement to record agonist-dependent cellular responses in cells engineered to express ligand-gated ion channels and grown on a microelectrode surface. Application of glutamate, a natural agonist, induced a complex and robust potentiometric response in cells expressing homomeric GluR-D glutamate receptor, but not in nonexpressing control cells. The response consisted of an initial decrease in outer potential followed by a transient increase and was not obtained for other amino acids devoid of agonist activity at glutamate receptors. Furthermore, the pharmacological agonist of the GluR-D receptor, kainate, also produced the potentiometric response whereas 6-cyano-7-nitroquinoxaline-2,3-dione, a competitive antagonist, was not active in itself but attenuated the responses to glutamate. The time course of the measured changes was slow, which may be partially due to the ligand being applied by free diffusion but may also reflect a contribution by secondary changes in the behavior of the cells. This novel approach should be applicable to other ligand-gated ion channels and holds promise as a cell-based biosensor for high-throughput drug screening and other applications.

Animals↗

Cellular biosensing system for assessing immunomodulating effects on the inducible nitric oxide synthase (iNOS) cascade.

A cellular biosensing system has been constructed to assess the biological safety/toxicity of chemicals. Detection of nitric oxide (NO) by the cellular biosensing system was used as a readout for assessing the immunomodulating effects of various chemicals, because some are known to induce NO synthase (iNOS) activity thereby increasing NO production. The macrophage-like cell line, RAW264.7, was cultured on the electrode coated with a polyion complex layer. The potent immune activating abilities of lipopolysaccharide could be verified by the cellular biosensing system: NO release from cells was detected within 600 ms by double potential step chronoamperometry.

Adjuvants, Immunologic↗

Non-destructive monitoring of rpoS promoter activity as stress marker for evaluating cellular physiological status.

To monitor the extent of cellular physiological stress, the activity of the rpoS promoter was evaluated as a marker of the stress pathway. A reporter plasmid was constructed by inserting the GFPuv gene under the rpoS promoter and used to transform Escherichia coli cells. The fluorescence of the GFPuv protein was measured in intact cells in a non-destructive manner. The physiological status of the cells could be conveniently monitored using the rpoS-GFPuv reporter gene with respect to the cellular growth phase and to elevated ethanol and NaCl concentrations as two examples of environmental stress factors. Comparison of the response of different E. coli strains demonstrated an essential role of the relA gene in the induction of the rpoS-GFPuv reporter gene.

Alcohols↗

Cellular biosensing system for discovery of protein synthesis inhibitors with an electrochemical phosphate modulator to regulate the acid phosphatase gene expression of Saccharomyces cerevisiae.

A cellular biosensing system for screening protein synthesis inhibitors has been developed by linking an electrochemical phosphate modulator and matrix-immobilized yeast cells with an optical sensing device. To screen the protein synthesis inhibitors, yeast phosphatase gene regulating system has been employed by linking an electrochemical phosphate modulator. Since the yeast phosphatase gene coding gammaAPase is expressed, when the phosphate concentration in solution is lowered below the threshold, the gammaAPase production is triggered by lowering the phosphate concentration with the electrochemical phosphate modulator, and monitored continuously with the photometric device. The electrochemical phosphate modulator was assembled with matrix-immobilized yeast cells. The module could insert to ordinal cuvette to monitor the induced gammaAPase activity in an ordinal photometer. Using the system, induction profile of protein synthesis was easily observed and was affected remarkably by various protein synthesis inhibitors. This seems promising that the system can be applied for first screening process of de novo protein inhibitors. The cellular biosensing system seems promising in screening protein synthesis inhibitors.

Acid Phosphatase↗

Affinity capture of a mammalian DNA polymerase beta by inhibitors immobilized to resins used in solid-phase organic synthesis.

The application of resins normally used in solid-phase organic synthesis to the affinity capture of a mammalian DNA polymerase beta (pol beta) is reported. Lithocholic acid (LCA), an inhibitor of pol beta, was immobilized on various solid supports, and the batch affinity purification of pol beta from a mixture of proteins using these LCA-immobilized resins was examined. Of the resins tested, TentaGel was the most effective at purifying pol beta and at resisting nonspecific absorption of proteins. The immobilized LCA recognized pol beta specifically, which resulted in pol beta binding to the resin. Using the LCA-immobilized resin, it was possible to purify pol beta from a mixture of proteins. Furthermore, it was possible to concentrate pol beta from a crude nuclear extract of human T lymphoma Molt4 cells. To facilitate the immobilization of compounds on TentaGel resins, we also designed and prepared photoaffinity beads containing a photoreactive group at the free termini of the TentaGel resin. The pol beta inhibitors LCA, C18-beta-SQDG, and epolactaene were immobilized on the photoaffinity beads by photoreaction. The batch affinity purification of pol beta from a protein mixture could be also achieved with these beads.

Chromatography, Affinity↗