PubMed Health⌕ Search

Biomedical subjects

Tetsuya Yuasa

Publications and source records attributed to Tetsuya Yuasa.

12 recordsLinked to original sources

Hard-x-ray region tomographic reconstruction of the refractive-index gradient vector field: imaging principles and comparisons with diffraction-enhanced-imaging-based computed tomography.

The unique tomographic imaging method based on refractive effects that was recently developed by Maksimenko et al. [Appl. Phys. Lett. 86, 124105 (2005)] exhibits an excellent imaging property in the hard-x-ray region for phase objects such as soft materials and biological samples. However, there seems to have been little consideration of the physical aspects of the underlying imaging principles. Also, as the method is similar to diffraction-enhanced-imaging (DEI)-based computed tomography (CT), the difference between these two methodologies has not been made clear. We theoretically consider the imaging principles starting from the measurement process to the reconstruction procedures from the viewpoint of geometrical optics and then clarify their difference in relationship to the physical quantities to be depicted. The major feature of this novel method is the in-plane two-dimensional vector-field reconstruction of the refractive-index gradient in an object, while DEI CT obtains the out-of-plane scalar-field gradient component. In other words, the novel method and DEI CT present the transverse and the longitudinal components, respectively, of the three-dimensional vector fields of the gradient refractive index. Therefore they can be considered complementary to each other.

Algorithms↗

Interlaced x-ray microplanar beams: a radiosurgery approach with clinical potential.

Studies have shown that x-rays delivered as arrays of parallel microplanar beams (microbeams), 25- to 90-microm thick and spaced 100-300 microm on-center, respectively, spare normal tissues including the central nervous system (CNS) and preferentially damage tumors. However, such thin microbeams can only be produced by synchrotron sources and have other practical limitations to clinical implementation. To approach this problem, we first studied CNS tolerance to much thicker beams. Three of four rats whose spinal cords were exposed transaxially to four 400-Gy, 0.68-mm microbeams, spaced 4 mm, and all four rats irradiated to their brains with large, 170-Gy arrays of such beams spaced 1.36 mm, all observed for 7 months, showed no paralysis or behavioral changes. We then used an interlacing geometry in which two such arrays at a 90-degree angle produced the equivalent of a contiguous beam in the target volume only. By using this approach, we produced 90-, 120-, and 150-Gy 3.4 x 3.4 x 3.4 mm(3) exposures in the rat brain. MRIs performed 6 months later revealed focal damage within the target volume at the 120- and 150-Gy doses but no apparent damage elsewhere at 120 Gy. Monte Carlo calculations indicated a 30-microm dose falloff (80-20%) at the edge of the target, which is much less than the 2- to 5-mm value for conventional radiotherapy and radiosurgery. These findings strongly suggest potential application of interlaced microbeams to treat tumors or to ablate nontumorous abnormalities with minimal damage to surrounding normal tissue.

Animals↗

High-pass-filtered diffraction microtomography by coherent hard x rays for cell imaging: theoretical and numerical studies of the imaging and reconstruction principles.

This paper presents theoretical and numerical studies of diffraction tomography using hard x rays, from the viewpoint of imaging and reconstruction methods for cell imaging. The proposed system employs a single-perfect-crystal analyzer in symmetric Laue-case transmission geometry to efficiently detect the higher spatial frequency components of an object's refractive-index distribution, and to effectively suppress interference between the unperturbated wave field and the wave field diffracted by the object. This system features acquisition of a single projection by a single exposure using a simple geometry and aggressive use of diffracted x rays. We present the physical description of the imaging method using the Fourier diffraction theorem derived from the Born approximation. First, we demonstrate that the reconstruction leads to the phase-retrieval problem. We then describe a reconstruction algorithm based on the classical Gerchberg-Saxton-Fienup algorithm. Finally, we show the efficacy of this system by computer simulation. Our simulation demonstrates that the imaging system delineates microstructure 3.5 microm in diameter in a phase object 400 microm in diameter.

Algorithms↗

Proliferation and differentiation of cultured MC3T3-E1 osteoblasts on surface-layer modified hydroxyapatite ceramic with acid and heat treatments.

Effects of functionally gradient calcium phosphate consisting of hydroxyapatite (HAP) and alpha-tricalcium phosphate (alpha-TCP) on proliferation and differentiation of osteoblasts were evaluated using MC3T3-E1 cells. There were no significant differences in the proliferation of MC3T3-E1 cells among HAP-alpha-TCP functionally gradient calcium phosphate, pure HAP, and cell culture plastic wells. mRNA expressions of type I collagen, alkaline phosphate, and osteocalcine were evaluated as indexes of initial; mid-stage, and late-stage osteoblastic differentiation. Basically, HAP-alpha-TCP functionally gradient calcium phosphate and pure HAP enhanced the expressions of the three markers when compared with that of cell culture plastic wells. For type I collagen and alkaline phosphate expressions, HAP-alpha-TCP functionally gradient calcium phosphate showed the same expression level as pure HAP. For osteocalcine expression, HAP-alpha-TCP functionally gradient calcium phosphate showed a higher level than pure HAP. We concluded, therefore, HAP-alpha-TCP functionally gradient calcium phosphate has good potential to be a bone filler material with high osteoconductivity.

3T3 Cells↗

Effects of various sterilization methods on the setting and mechanical properties of apatite cement.

Sterilization capability is a necessary requirement for any material that is to be used in a medical application. Therefore, it is necessary for apatite cement (AC) to be sterilized. Because there is little information on the sterilization methods of AC, the aims of this investigation were to evaluate the effects of various sterilization methods, including steam, dry heat, ethylene oxide (EtO) gas, and gamma irradiation sterilizations, on the setting and mechanical properties of AC. In the case of steam sterilization, because AC powder aggregated before setting-time measurements, the setting time could not be measured. When the powder was sterilized by dry heat or EtO gas, the setting time was prolonged significantly and the wet diametral tensile strength (DTS) value decreased significantly. Therefore, sterilizations with steam, dry heat, or EtO gas were suggested to be inappropriate methods for AC. Accordingly, the following experiments focused on gamma sterilization. The setting time of AC was retarded with an increase in gamma irradiation dose. The wet DTS value decreased with the increase in gamma irradiation dose. There was no compositional change due to the gamma irradiation. The following tests were carried out in order to examine the effect of the gamma irradiation on the setting reaction of AC in detail. Tetracalcium phosphate [TTCP: Ca(4)(PO(4))(2)O] and dicalcium phosphate anhydrous (DCPA: CaHPO(4)) were separately irradiated, and the cements were produced with the use of irradiated powder and nonirradiated powder. Although the wet DTS value of AC produced from irradiated TTCP and nonirradiated DCPA decreased with increasing gamma irradiation dose, there was no significant difference. In contrast, the wet DTS value of AC produced from irradiated DCPA and nonirradiated TTCP significantly decreased with the increase in gamma irradiation dose. In conclusion, although the detailed mechanism of the delayed setting time and decreased DTS value was not clarified by the present study, it was found that gamma irradiation affected DCPA more than TTCP.

Adhesives↗

Effects of neutral sodium hydrogen phosphate on the setting property and hemostatic ability of hydroxyapatite putty as a local hemostatic agent for bone.

Hydroxyapatite (HAP) putty has been reported to have good hemostatic ability and excellent biocompatibility. Although the setting reaction of HAP putty and resulting transformation to HAP is the reason for this excellent biocompatibility, it also limits the handling period. In this study, the relationship between the setting reaction of HAP putty and its hemostatic ability was investigated, where neutral sodium hydrogen phosphate concentration and post-preparation time were used as indexes. A higher concentration of neutral sodium hydrogen phosphate was found to result in decreased hemostatic ability. The hemostatic ability of HAP putty decreased with time after its preparation; thus it was important to use HAP putty within 10 min after its preparation. The adhesive strength of HAP putty to bone increased with time. Therefore reliable hemostasis can be expected with HAP putty. Although the limited handling time is a drawback, HAP putty is thought to have a good potential as a hemostatic agent-it is highly reliable, and has a high hemostatic ability with excellent biocompatibility.

Animals↗

Effect of the additional installation of implants in the posterior region on the prognosis of treatment in the edentulous mandibular jaw.

The aim of this study was to elucidate the effect of the additional installation of implants in the posterior region on the prognosis of treatment in the edentulous mandibular jaw. Fifteen patients who had received implants (Brånemark system, Nobel Biocare, Gotebörg, Sweden) in the edentulous mandible and completed a 1-year follow-up after the fitting of implant-anchored fixed prostheses were selected. In seven patients (Group A), four or five implants were installed between the mental foramina, and in eight patients (Group P), one or two implants, one on each side, were installed in the posterior regions in addition to the implants between the foramina. All implants of both groups achieved osseointegration. In Group A, there was no implant loss after loading. Six implants were lost in five patients of Group P within 1 year after loading. All of them were located in the posterior region. To elucidate whether or not the failure rate of the implants in the posterior region of Group P after loading was especially high, the failures were also compared with 89 implants, which were installed in the posterior region of the mandibles to support implant-anchored fixed partial prosthesis, during the same period (Group C). The cumulative survival rate of the implants of Group P was 60%, while that of the implants of Group C was 100% (P<0.001). When the survival rates of posterior implants with the same length of the two groups were compared, there were significant differences for the 7- and 10-mm-length implants only. These data demonstrate that the posterior implants in Group P are at greater risk. Deformation of the mandible due to jaw movement was thought to be the most likely cause of the implant loss. Therefore, when such modified treatment is chosen, it should be performed with meticulous attention.

Adult↗

Evaluation of feasibility of hydroxyapatite putty as a local hemostatic agent for bone.

Although bone wax is known to cause an inflammatory reaction in soft tissue and a delay of bone healing, it is usually the first choice to arrest bleeding from bone. Hydroxyapatite (HAP) putty is proposed here. This study evaluated the feasibility of HAP putty with respect to whether or not it has potential value as a hemostatic agent for bone. First, the adhesive strength of HAP putty to bone was evaluated. The adhesive strength of HAP putty to wet bone was much higher when compared with that of bone wax, even though the adhesive strengths of HAP putty and bone wax to dry bone were equivalent. Next, to evaluate the hemostatic ability of HAP putty, bony defects were made in rabbits. HAP putty could arrest bleeding from bone within 3 min. However, when the hemostasis was performed with bone wax, bleeding was arrested within 8 min. Thus, HAP putty showed better hemostatic ability than bone wax. Finally, the tissue response to HAP putty in rabbit subcutaneous tissue was evaluated. Histological observation revealed a slight inflammatory response around HAP putty, whereas bone wax was surrounded by moderate inflammatory tissue. In conclusion, HAP putty has good potential value to be a hemostatic agent for bone because it has strong adhesion, good hemostatic ability, and biocompatibility.

Adhesiveness↗

Fabrication of Zn containing apatite cement and its initial evaluation using human osteoblastic cells.

Recently, the effects of Zn2+ on osteogenesis stimulation have become major topics in the research fields of bone formation and organism essential elements. Based on the fundamental finding of Zn2+ with respect to osteogenesis stimulation, Ito et al. have prepared Zn doped beta-tricalcium phosphate (ZnTCP) and have reported that ZnTCP enhances the proliferation of MC3T3-E1 cells. In this investigation, we studied the effects of ZnTCP added to apatite cement (AC) with respect to its setting reaction and proliferation of human osteoblastic cells as an initial evaluation for the feasibility of AC containing ZnTCP. Compositional analysis using powder X-ray diffractometer revealed that ZnTCP shows no reactivity with the setting reaction of AC. As a result, the mechanical strength of set AC decreased increasing amounts of added ZnTCP as if ZnTCP acts as a pore in AC. The setting time of AC was not affected by addition of ZnTCP up to 10%. When AC containing ZnTCP was immersed in alpha-MEM containing 10% bovine serum, Zn2+ was released from AC. Larger amounts of Zn2+ were released from AC containing larger amounts of ZnTCP. When human osteoblastic cells were incubated on the surface of AC discs, proliferation of human osteoblastic cells was significantly increased on the surface of AC that contained 5% ZnTCP when compared with that containing no ZnTCP. In contrast, proliferation of human osteoblastic cells decreased on the surface of AC that contained 10% ZnTCP when compared with that free from ZnTCP; indicating cytotoxicity. We concluded therefore, that addition of ZnTCP to AC is useful to enhance the osteoconductivity of AC when release of Zn2+ can be carefully regulated.

Apatites↗

The in vitro antibiotic release from anti-washout apatite cement using chitosan.

The in vitro antibiotic release from anti-washout apatite cement using chitosan (aw-AC(chi)) was investigated in a preliminary evaluation. Flomoxef sodium was employed as the antibiotic and was incorporated into the powder phase aw-AC(chi) at up to 10%. The setting times were measured for aw-AC(chi) containing various amounts of flomoxef sodium. X-ray diffraction (XRD) analysis was also conducted for the identification of products. To evaluate the drug release profile, set aw-AC was immersed in saline and the released flomoxef sodium was determined at regular intervals. The setting time was prolonged slightly with the addition of flomoxef sodium. The difference at 10% flomoxef sodium (0% vs. 10%) was not significant (p>0.05), and can be negligible in clinic. The XRD analysis revealed that formation of hydroxyapatite (HAP) from aw-AC(chi) was reduced, even after 24 h, when the aw-AC(chi) contained flomoxef sodium at 8% or more. The flomoxef sodium release from aw-AC(chi) showed the typical profile observed in skeleton type drug delivery system (DDS). Changing the concentration of chitosan can control the rate of drug release from aw-AC. Therefore, we conclude that aw-AC(chi) is a good candidate for potential use as a DDS carrier that may be useful in surgical operations.

Journal Article↗

Fundamental imaging properties of transillumination laser computed tomography based on coherent detection imaging method.

The coherent detection imaging (CDI) method uses the optical heterodyne detection technique. CW and single frequency lasers having long coherence lengths are used to exploit the maximum advantages of heterodyne detection, such as high directionality, selectivity and sensitivity. The CDI method based on optical heterodyne detection enables selective filtering of the directional coherence-retaining emergent photons, which leads to image reconstruction from projections, similar to X-ray computed tomography (CT). So far we have demonstrated the advantages and capabilities of the measurement technique for transillumination optical computed tomography in biomedicine. Here, we investigate the fundamental imaging properties of CDI method, such as its high directionality and quantitativeness, with preliminary physical phantom experiments. The results show that the CDI method satisfies the requirements for CT reconstruction under the first order approximation, and enables quantitative measurements in the sense that the relationship between estimated and actual concentration retains a satisfactory linearity.

Equipment Design↗

Effects of apatite cements on proliferation and differentiation of human osteoblasts in vitro.

Although apatite cement (AC) and sintered hydroxyapatite (s-HAP) are known to show good osteoconductivity, it is not clear whether or not the degree of their osteoconductivity is the same. In addition, it has not been clarified whether or not it is dependent on the type of AC; conventional AC (c-AC), fast-setting AC (fs-AC) or anti-washout AC (aw-AC). The aim of this study was to investigate the effects of ACs on cultured human osteoblasts, as they may provide a useful index of osteoconductivity. Human osteoblasts were cultured on the surfaces of ACs and s-HAP, and were evaluated with respect to cell attachment, proliferation, and differentiation. We found that ACs and s-HAP showed similar cell attachment. No significant difference between ACs and s-HAP was found with respect to the proliferation of osteoblasts. In contrast, we found that the differentiation of osteoblasts was enhanced on the surface of ACs compared with that of s-HAP. However, there was no difference among the types of AC. We therefore concluded that AC may show better osteoconductivity than s-HAP, and that osteoconductivity of AC may be similar, regardless of the type of AC.

Biocompatible Materials↗