PubMed Health⌕ Search

Biomedical subjects

Theodora Koraki

Publications and source records attributed to Theodora Koraki.

2 recordsLinked to original sources

High-throughput double quantitative competitive polymerase chain reaction for determination of genetically modified organisms.

Quantitative competitive polymerase chain reaction (PCR), especially the double competitive PCR methods (DC-PCR), have evolved as reliable approaches to quantification of genetically modified organisms (GMO) in food. However, DC-PCR is a low-throughput method because it requires titration of each sample with various amounts of a competitive internal standard, a protocol that involves several PCRs per sample followed by electrophoresis and densitometry. To address this drawback, we have developed a new method for GMO quantification, namely, a high-throughput double quantitative competitive PCR (HT-DCPCR). In HT-DCPCR, electrophoresis and densitometry are replaced by a rapid, microtiter well-based bioluminometric hybridization assay and there is no need for titration of each sample. The determination of GM soya was chosen as a model. We have constructed internal standards (DNA competitors) both for the 35S promoter sequence and for a plant-specific reference gene (lectin). The competitors have identical size and share the same primer binding sites with the target sequences but differ in a 24-bp internal segment. Each target sequence (35S and lectin) is coamplified with a constant amount (1000 copies) of the respective competitor. The four amplified fragments are hybridized with specific probes and captured on a universal solid phase to achieve simplicity and high throughput. The hybrids are determined by using streptavidin conjugated to the photoprotein aequorin. The ratio of the luminescence values obtained for the target and the competitor is linearly related to the starting amount of target DNA. The limit of quantification for the 35S promoter is 24 copies. The proposed method was evaluated by determining the GMO content of soybean powder certified reference materials. Also HT-DCPCR was compared to real-time PCR in a variety of real samples.

Calibration↗

Nanoparticle-based DNA biosensor for visual detection of genetically modified organisms.

Although screening of raw ingredients and food products for genetically modified organisms (GMO) may be accomplished by detecting either the exogenous DNA or the novel protein, DNA is the preferred analyte because of its superior stability during food processing. The development of DNA biosensors is of increasing importance due to the growing demand for rapid and reliable methods for GMO detection. We report the first DNA biosensor in a dry-reagent dipstick configuration for visual detection and confirmation of GMO-related sequences by hybridization within minutes. The sensor is disposable and does not require special instrumentation. It detects the 35S promoter and nopaline synthase (NOS) terminator sequences that are present in the majority of transgenic plants. The target sequences are amplified by the polymerase chain reaction (PCR) and hybridized (7min) with probes bearing oligo(dA) tail. The biotinylated product is applied to the sensor followed by immersion in the appropriate buffer. Migration of the buffer rehydrates gold nanoparticles conjugated to oligo(dT), which hybridize with the oligo(dA) tails. The hybrids are captured by immobilized streptavidin at the test zone of the sensor giving a characteristic red line due to the accumulation of the nanoparticles. The excess of nanoparticle conjugates are captured at the control zone by immobilized oligo(dA) strands. Amplified 35S or NOS DNA is detectable at 0.16nM. Soybean powder certified reference material with 0.1% GMO content is clearly detectable after 35 and 40 amplification cycles for 35S and NOS sequence, respectively. The sensor was also applied to real samples from various sources.

Biosensing Techniques↗