PubMed Health⌕ Search

Biomedical subjects

Thierry Bové

Publications and source records attributed to Thierry Bové.

6 recordsLinked to original sources

Stentless and stented aortic valve replacement in elderly patients: Factors affecting midterm clinical and hemodynamical outcome.

OBJECTIVE: To report on the midterm results of aortic valve replacement (AVR) with stented and stentless bioprosthesis in an elderly population by analyzing the factors affecting survival and hemodynamical performance. METHODS: In a retrospective study, 145 patients with a Toronto stentless prosthesis are compared with 110 patients with a stented Carpentier-Edwards valve. The 5- to 10-year clinical outcome, transprosthetic gradients, and early and late left ventricular mass (LVM) regression are analyzed in view of specific prosthesis- and patient-related factors. RESULTS: Actuarial survival at 5 years is 82% after stentless AVR versus 68% after stented AVR (p < 0.001) in elderly patients. However, there was no difference in survival at 8 years, being 55.9% and 59.5%, respectively. Univariate analysis revealed that advanced age at the time of operation, NYHA class IV, use of a stented xenograft, presence of patient-prosthesis mismatch (PPM) (IEOA < or = 0.85 cm2/m2), and severe preoperative left ventricular (LV) hypertrophy (LVMI > 180 g/m2) affected survival adversely. But multivariate analysis determined only age, NYHA class IV and excessive LV hypertrophy as independent predictors of late mortality. Stented and stentless xenografts were equally effective in terms of transprosthetic gradients and LVMI regression. The use of a stentless valve significantly reduced the occurrence of PPM (18% vs 41%, p < 0.01). Early LVMI regression at 1 year was optimized by the avoidance of PPM, indicated by a higher absolute (43.7+/-28.3 g/m2 vs 58.6+/-33.8 g/m2, p = 0.003) and relative (25.0+/-12.7% vs 31.4+/-14.9%, p=0.004) mass regression. However, late LV remodeling was predominantly affected by systemic hypertension and severe preoperative LV hypertrophy, resulting in the incomplete LVMI resolution in 61.3% and 66.7% of these patients, respectively. CONCLUSION: In elderly patients, aortic valve replacement appears to be equally effective with a stentless or stented bioprosthesis. Midterm clinical outcome is mainly determined by patient-related factors such as age, advanced NYHA class, and severity of preoperative LV hypertrophy. Regarding post-AVR left ventricular remodeling, patient-prosthesis mismatch influences the early phase, whereas arterial hypertension affects the late regression more. However, the left ventricular remodeling is continuously compromised by the preoperative presence of excessive hypertrophy, despite the efficacy of the aortic valve replacement.

Aged↗

Stentless vs. stented aortic valve replacement: left ventricular mass regression.

The aim of this retrospective study was to evaluate the time-related regression of left ventricular hypertrophy after stentless vs. stented aortic valve replacement. From January 1992 to December 2002, 145 patients had a Toronto stentless porcine valve and 106 had a stented Carpentier-Edwards aortic valve replacement. Over a 10-year follow-up, survival was superior in the Toronto group vs. the Carpentier-Edwards group (84% vs. 74% at 4 years; 78% vs. 68% at 6 years; p < 0.001). A significant and constant reduction of peak and mean transvalvular gradients after valve replacement resulted in substantial regression of left ventricular mass index in both groups, which did not reach statistical significance. However, this phenomenon stopped at 3 years, and left ventricular mass index increased slowly after 5 years. Stentless and stented bioprostheses both showed good early and late clinical and hemodynamic outcomes, with the advantage of better midterm survival for stentless xenografts.

Adult↗

Aortic valve replacement with Toronto SPV in elderly patients: 10-year results.

A retrospective assessment of clinical and echocardiographic variables was performed in 145 patients who received a Toronto SPV aortic valve replacement. The majority (90%) of these elderly patients (mean age, 75.5 +/- 7.4 years) were preoperatively in New York Heart Association class III-IV. Operative mortality was 4.8%. Follow-up was complete up to 10 years and revealed few valve-related complications: thromboembolism (7), bleeding (4), and prosthesis dysfunction necessitating reoperation (3). Late mortality was cardiac-related in 11.7% and noncardiac-related in 17.2%. Actuarial survival was 83% at 5 years and 63% at 8 years. Echocardiography showed low transvalvular gradients (peak, 17.5 +/- 7.5 mm Hg; mean, 9.2 +/- 4.2 mm Hg) resulting in a significant reduction in left ventricular mass index during the first 3 years. Independent of the transprosthetic gradient, left ventricular mass index tended to increase again beyond the 5th year, which correlated positively with the presence of arterial hypertension in this older population. The Toronto SPV bioprosthesis offers an aortic valve substitute with excellent long-term hemodynamics, resulting in significant early left ventricular mass regression. Considering the limitations of this selected elderly population, the clinical outcome and survival up to 10 years are encouraging, with few observed valve-related events.

Aged↗

Outcome analysis of major cardiac operations in low weight neonates.

BACKGROUND: From June 1995 to January 2003, 49 consecutive neonates of less than 2,500 g underwent early surgery for congenital heart disease. A retrospective analysis was performed to evaluate the early to medium term outcome. METHODS: Major cardiac surgery for congenital heart defects included a complete correction in 31 patients (group I) and a palliative procedure in 18 patients (group II). Mean age at operation was 15.2 days (1 day-90 days) and mean weight was 2,190 g (1,300 g-2,500 g). Twenty-four children (49%) were born prematurely. All neonates were critically ill and 47% were already ventilated preoperatively. Heart defects included mainly ventricular septal defect (10), tetralogy of Fallot complexes (8), aortic coarctation (8), transposition complexes (7), single ventricle anomalies (4), pulmonary atresia with intact septum (4), interrupted aortic arch (3), totally anomalous pulmonary venous return (3), and common atrioventricular septal defect (2). RESULTS: Overall surgical mortality was 18%: 4 neonates died after definitive repair and 5 after palliation; representing, respectively, 13% and 28% of each group. Postoperative morbidity occurred in half of the patients (53%). Age, weight, prematurity, type of first surgical procedure, and use of cardiopulmonary bypass did not influence the early outcome. After a mean follow-up of 2.82 years (2 months to 6 years), survival was 87% in the correction group and 54% in the palliation group. All children were in NYHA class I-II. Freedom from reintervention at 18 months was 68% after correction versus 8% after palliation. CONCLUSIONS: Cardiac surgery for congenital malformations in critically ill, low weight neonates can be achieved with acceptable mortality, at the cost of an increased morbidity. Early outcome seems independent of age, weight, prematurity, use of extracorporeal perfusion, and type of first intervention. Moreover, primary correction appears to result in an early survival benefit, remaining constant over time.

Birth Weight↗

Early results of valved bovine jugular vein conduit versus bicuspid homograft for right ventricular outflow tract reconstruction.

BACKGROUND: Homograft conduits are preferable for right ventricular outflow tract reconstruction in children, but their limited availability remains a major concern. Recently, a valve-containing segment of bovine jugular vein (Contegra, Medtronic Inc, Minneapolis, MN) has been introduced as a potential alternative conduit. METHODS: Early clinical and echocardiographic results of right ventricular outflow tract reconstruction were retrospectively compared between 41 children (mean age, 1.9 years), receiving a Contegra conduit and 36 patients (mean age, 2.7 years) with a size-reduced pulmonary homograft. RESULTS: Clinical outcome was comparable with two early deaths in the homograft group and one in the Contegra group. There were no conduit-related complications in either population. Early echocardiographic assessment showed only trivial to mild regurgitation in 9 homografts versus 17 Contegra conduits. The peak gradient across the right ventricular outflow tract conduit was comparable for both groups, although a larger number of patients, treated with a downsized homograft, had a small gradient at the distal junction with the pulmonary arteries (12 versus 6 patients). None of the patients had a gradient at the valvar level. CONCLUSIONS: The valved bovine jugular vein conduit offers a promising substitute for right ventricular outflow tract reconstruction in infants and children, with an early hemodynamic performance that compares favorably with downsized, bicuspid homografts. Clinical advantages are greater shelf availability and the natural continuity between valve and conduit, which allows proximal infundibular shaping without additional material. However, durability must be determined, even though most of these children will require right ventricular outflow tract reoperation after outgrowing the conduit.

Adolescent↗