PubMed Health⌕ Search

Biomedical subjects

Thilo Hölscher

Publications and source records attributed to Thilo Hölscher.

11 recordsLinked to original sources

Intraoperative brain ultrasound: a new approach to study flow dynamics in intracranial aneurysms.

The aim was to evaluate the potential of contrast-enhanced ultrasound to visualize the hemodynamics in intracranial aneurysms during neurosurgical intervention and to quantify the ultrasound data using digital particle image velocimetry (DPIV) technique. Aneurysms were scanned through the intact dura mater, preclipping and again postclipping after closure of the dura. After intravenous injection of Optison, angio-like views of the vascular tree surrounding the aneurysm, including the aneurysm sac, were obtained. Single ultrasound contrast agent microbubbles could be visualized in the aneurysm sac and the flow dynamics could be assessed in vivo. Spatial and temporal distributions of the velocity in the aneurysm and in the parent vessels were measured with DPIV using the backscattered signals from the microbubbles. Subsequently, the fluid stresses, vorticity, circulation, etc., were calculated from the velocity fields. We demonstrate in this paper that intraoperative contrast-enhanced ultrasound can be used to quantify the flow dynamics within an aneurysm.

Albumins↗

Transcranial ultrasound brain perfusion assessment with a contrast agent-specific imaging mode: results of a two-center trial.

BACKGROUND AND PURPOSE: The purpose of this study was to assess brain perfusion with an ultrasound contrast-specific imaging mode and to prove if the results are comparable between 2 centers using a standardized study protocol. METHODS: A total of 32 individuals without known cerebrovascular disease were included in the study. Perfusion studies were performed ipsilaterally in an axial diencephalic plane after intravenous administration of 0.75 mL of Optison. Offline time intensity curves (TIC) were generated in different anatomic regions. Both centers used identical study protocols, ultrasound machines, and contrast agent. RESULTS: In both centers, the comparison of the parameter time to peak intensity (TPI) revealed significantly shorter TPIs in the main vessel structures compared with any parenchymal region of interest (ROI), whereas no significant differences were seen between the parenchymal ROIs. The parameter peak intensity (PI) varied widely interindividually in both centers, whereas the inter-ROI comparison revealed statistical significance (P < 0.05) in most of the cases according to the following pattern: (1) lentiforme nucleus > thalamus and white matter region, (2) thalamus > white matter region, and (3) main vessel > any parenchymal structure. Similar results were achieved in both centers independently. CONCLUSIONS: The study demonstrates that brain perfusion assessment with an ultrasound contrast-specific imaging mode is comparable between different centers using the same study protocol.

Adult↗

Transcranial ultrasound angiography (T USA): a new approach for contrast specific imaging of intracranial arteries.

The goal was to develop an ultrasound contrast agent-specific imaging mode that offers an angiography-like view of the intracranial arteries and enables lower mechanical index MI settings compared to conventional transcranial duplex sonography. We studied 12 patients with transcranial ultrasound angiography (t USA) via the temporal bone window after an IV bolus injection of a perfluorocarbon-based microbubble contrast agent (Imagent). The aim was to display the intracranial vessel segments of the middle cerebral artery (M1, M2 and M3), the anterior cerebral artery (A1 and A2), the posterior cerebral artery (P1, P2 and P3) and the internal carotid artery (C1/2 and C3/4). t USA is a B-mode phase inversion imaging technique that uses wideband harmonic signals for image generation. We demonstrate, in this report, that t USA provides detailed anatomical display at native B-mode spatial resolution with fewer artifacts, yielding improved delineation of intracranial vessels that are in the 1- to 2-mm range.

Adolescent↗

Detection of cardiac right-to-left shunts by contrast-enhanced harmonic carotid duplex sonography.

OBJECTIVE: Paradoxical embolization by cardiac right-to-left shunts (RLS) is increasingly recognized as an important factor for embolic stroke. Contrast-enhanced transcranial Doppler sonography (ce-TCDS) is an established diagnostic tool for RLS detection but is frequently limited because of an inadequate temporal acoustic bone window. The purpose of this study was to determine whether extracranial sonography (ECS) using harmonic frequencies improves detection of RLS. METHODS: Extracranial color duplex sonography using harmonic frequencies enables visualization of even single ultrasound contrast agent microbubbles because of oscillation. Patients with stroke and positive RLS findings on transesophageal echocardiography underwent a simultaneous extracranial and transcranial sonographic examination of the proximal common carotid artery (CCA) and middle cerebral artery (MCA) on the same side. A Valsalva strain was performed for 10 seconds after intravenous bolus injection of a galactose-based nontranspulmonary contrast agent. The B-mode frame sequences of the transverse plane of the CCA obtained by harmonic ECS and the ce-TCDS recordings of high-intensity transient signals from the MCA were analyzed offline. RESULTS: In all patients with RLS, the shunts could be identified by harmonic ECS. A close correlation could be seen between the count of visualized microbubbles in the CCA and the number of high-intensity transient signals detected on ce-TCDS in the ipsilateral MCA. CONCLUSIONS: The results of this study indicate that contrast-enhanced ultrasound harmonic imaging of the CCA using a Valsalva strain might be an optional screening tool for detection of cardiac RLS in patients with insufficient acoustic bone windows.

Carotid Artery, Internal↗

Validation of the depletion kinetic in semiquantitative ultrasonographic cerebral perfusion imaging using 2 different techniques of data acquisition.

OBJECTIVE: To validate the potential of ultrasonographic depletion imaging for semiquantitatively visualizing cerebral parenchymal perfusion with contrast burst depletion imaging (CODIM) in comparison with phase inversion harmonic depletion imaging (PIDIM) in healthy volunteers. METHODS: Thirteen healthy adults were examined with both CODIM and PIDIM in accordance with previously described criteria. In addition to the perfusion coefficient, the time to decrease image intensity to 10% above equilibrium intensity from the initial value and the relative error (deviation of measured data from the fitted model) were evaluated to compare the reliability of both techniques in 3 different regions of interest. RESULTS: Perfusion coefficient values did not show significantly differing values in both groups (1.57-1.64 * 10(-2) s(-1) for CODIM and 1.42-1.58 * 10(-2) s(-1) for PIDIM). The relative error was significantly smaller in the PIDIM group (0.38-0.53 for CODIM and 0.18-0.25 for PIDIM; P < .002). CONCLUSIONS: Phase inversion harmonic depletion imaging proved to be more reliable than CODIM because values of the relative error were significantly lower in PIDIM even in this relatively small cohort. This is of interest because the underlying technique, phase inversion harmonic imaging, is more widely available than contrast burst imaging.

Adult↗

Brain perfusion imaging of a craniopharyngioma by transcranial duplex sonography.

BACKGROUND AND PURPOSE: The aim of this study was to test a new ultrasound software tool to assess pathological perfusion in a brain tumor patient. METHODS: Tissue harmonic imaging (THI) enables an improved depiction of brain morphology, employing nonlinear parenchyma and ultrasound contrast agent (UCA) backscatter information. With specialized software, morphological information can be separated from perfusion information. Both can be superimposed at a preferred mixing ratio in a single image. RESULTS: Using THI and a perfluoropropane-based UCA, a pathologic perfusion pattern described by abnormal perfused areas in the tumor region could be demonstrated. After superimposing morphologic and perfusion information, subtle structural tumor inhomogeneities were depicted. Craniopharyngioma structure and perfusion defect were confirmed by T2-weighted and perfusion-weighted magnetic resonance imaging. CONCLUSION: Transcranial duplex sonography in combination with contrast specific imaging methods might be helpful to visualize perfusion defects without loss of morphological information.

Adult↗

Transcranial duplex sonography in the detection of patent foramen ovale.

PURPOSE: To determine the sensitivity of contrast material-enhanced transcranial color-coded sonography (c-TCCS) compared with that of contrast-enhanced transesophageal echocardiography (c-TEE) for detection of cardiac right-to-left shunt. MATERIALS AND METHODS: Forty consecutive patients with stroke or transient ischemic attack were admitted to the hospital and were examined by using c-TCCS and c-TEE. High-intensity transient signals (HITS) were counted for 25 seconds after the end of the Valsalva maneuver, and the numbers of HITS were classified in one of four categories (zero HITS, one to 10 HITS, >10 HITS without curtain, and curtain). A statistically significant difference was calculated with the Fisher exact test. RESULTS: HITS were counted in 21 (52%) patients by using c-TCCS and c-TEE. With both tests, no HITS were counted in 15 (38%) patients. In two (5%) patients, no HITS were counted with c-TEE but three HITS in one patient and five HITS in the other were counted with c-TCCS. In two (5%) patients, no HITS were counted with c-TCCS, but a small patent foramen ovale (PFO) was seen at c-TEE. With c-TCCS, the sensitivity was 91% (21 of 23) and the specificity was 88% (15 of 17). In 23 patients examined with c-TCCS, 14 (61%) patients had category 1 PFO; seven (30%) patients, category 2 PFO; and two (9%) patients, category 3 PFO. Mean HITS count in patients with category 1 PFO was 4.4 and that for those with category 2 PFO was 27.6. CONCLUSION: c-TCCS is a sensitive noninvasive method for detecting cardiac right-to-left shunt and is as sensitive as c-TEE.

Echocardiography, Transesophageal↗

Comparison between echo contrast agent-specific imaging modes and perfusion-weighted magnetic resonance imaging for the assessment of brain perfusion.

BACKGROUND AND PURPOSE: Contrast burst imaging (CBI) and time variance imaging (TVI) are new ultrasonic imaging modes enabling the visualization of intravenously injected echo contrast agents in brain parenchyma. The aim of this study was to compare the quantitative ultrasonic data with corresponding perfusion-weighted MRI data (p-MRI) with respect to the assessment of brain perfusion. METHODS: Twelve individuals with no vascular abnormalities were examined by CBI and TVI after an intravenous bolus injection of 4 g galactose-based microbubble suspension (Levovist) in a concentration of 400 mg/mL. Complementary, a dynamic susceptibility contrast MRI, ie, p-MRI, of each individual was obtained. In both ultrasound (US) methods and p-MRI, time-intensity curves were calculated offline, and absolute time to peak intensities (TPI), peak intensities (PI), and peak width (PW) of US investigations and TPI, relative cerebral blood flow (CBF) and relative cerebral blood volume (CBV) of p-MRI examinations were determined in the following regions of interest (ROIs): lentiform nucleus (LN), white matter (WM), posterior (PT), and anterior thalamus (AT). In addition, the M(2) segment of the middle cerebral artery (MCA) was evaluated in the US, and the precentral gyrus (PG) was examined in the p-MRI examinations. In relation to a reference parenchymal ROI (AT), relative TPIs were compared between the US and p-MRI methods and relative PI of US investigations with the ratio of CBF (rCBF) of p-MRI examinations in identical ROIs. RESULTS: Mean TPIs varied from 18.3+/-5.0 (AT) to 20.1+/- 5.8 (WM) to 17.2+/-4.9 (MCA) seconds in CBI examinations and from 19.4+/-5.3 (AT) to 20.4+/-4.3 (WM) to 17.3+/-4.0 (MCA) seconds in TVI examinations. Mean PIs were found to vary from 581.9+/-342.4 (WM) to 1522.9+/-574.2 (LN) to 3400.9+/- 621.7 arbitrary units (MCA) in CBI mode and from 7.5+/-4.6 (WM) to 17.5+/-4.9 (LN) to 46.3+/-7.1 (MCA) arbitrary units in TVI mode. PW ranged from 7.3+/-4.5 (AT) to 9.1+/-4.0 (LN) to 24.3+/-12.8 (MCA) seconds in CBI examinations and from 7.1+/-3.9 (AT) to 8.7+/-3.5 (LN) to 26.7+/-18.2 (MCA) seconds in TVI examinations. Mean TPI was significantly shorter and mean PI and mean PW were significantly higher in the MCA compared with all other ROIs (P<0.05). Mean TPI of the p-MRI examinations ranged from 22.0+/-6.9 (LN) to 23.0+/-6.8 (WM) seconds; mean CBF ranged from 0.0093+/- 0.0041 (LN) to 0.0043+/-0.0021 (WM). There was no significant difference in rTPI in any ROI between US and p-MRI measurements (P>0.2), whereas relative PIs were significantly higher in areas with lower insonation depth such as the LN compared with rCBF. CONCLUSIONS: In contrast to PI, TPI and rTPI in US techniques are robust parameters for the evaluation of cerebral perfusion and may help to differentiate physiological and pathological perfusion in different parenchymal regions of the brain.

Adult↗

Observation on the integrity of the blood-brain barrier after microbubble destruction by diagnostic transcranial color-coded sonography.

OBJECTIVE: To investigate alteration of the blood-brain barrier from ultrasonic contrast agent destruction by diagnostic transcranial color-coded sonography using gadolinium-enhanced magnetic resonance imaging. METHODS: Healthy male volunteers received 10 mL (400 mg/dL) of Levovist (SH U 508A; Schering AG, Berlin, Germany; n = 6) or 3 mL of Optison (FS069; Mallinckrodt Inc, St Louis, MO; n = 4) followed by 0.3 mmol/kg magnetic resonance imaging contrast agent (Magnevist; Schering) intravenously. Then transcranial color-coded sonography was performed with a conventional color duplex sonographic system, which insonated the brain in a slightly angulated axial plane with temporal average intensity of less than 700 mW/cm2 or acoustic pressure amplitude of less than 2.69 MPa, attenuated by the temporal bone. Before, immediately after, and 2 hours after insonation, T1-weighted axial magnetic resonance imaging was performed. All magnetic resonance images were individually assessed, and T1 signal intensities were measured in 2 regions of interest in both hemispheres at the 3 time points. RESULTS: No focal contrast enhancement or damage to the brain and no significant difference between T1 signal intensities in the right and left brain regions could be detected during early or late phases when either ultrasonic contrast agent was used. CONCLUSIONS: This bioeffects study gives further evidence of the safety of ultrasonic destruction of Levovist and Optison microbubbles by diagnostic transcranial color-coded sonography. However, more subtle local effects may have been missed by gadolinium-enhanced magnetic resonance imaging. Studies on diagnostic contrast-enhanced transcranial color-coded sonography as well as microbubble-based drug delivery strategies should consider ultrasonic contrast agent microbubble characteristics and concentration as well as ultrasound transmission power levels.

Adult↗

Contrast-Enhanced Transcranial and Extracranial Duplex Sonography: Preliminary Results of a Multicenter Phase II/III Study with SonoVuetrade mark.

Transcranial sonography is an ultrasonographic application with real problems of insufficient signal to noise ratio, which make it a primary candidate for applying ultrasonographic contrast enhancing agents. Within an international randomized multicenter phase II/III study, we investigated ten patients with insufficient Doppler signal retrieval using transcranial and extracranial color-coded duplex sonography to define safety, toxicity, optimal dosing, and the potential of the new ultrasound contrast agent SonoVue(trade mark). Patients were studied with standard color duplex systems. SonoVue(trade mark) was administered by IV bolus injection at four different doses. Efficacy parameters included the assessment of global quality of Doppler investigations, color Doppler (CD), and spectral Doppler (SD) evaluated by semiquantitative analysis using a four-point scale from 0 to 3 (very poor to excellent) and the duration of clinically useful signal enhancement. In addition, CD enhancement, evaluated at best signal enhancement, was assessed using a five-point scale, from no enhancement, slight, moderate, optimal to excessive (0-4). All examinations were compared to "gold" standard imaging (magnetic resonance imaging, digital subtraction angiography) to evaluate diagnostic confidence at optimum dosage. No serious adverse events were observed. Mean signal increase over baseline in CD or SD was 2 out of 4 points. Mean time to appearance of contrast enhancement was 22.8 seconds (9-52 sec) at the optimal dosage. The mean duration of enhancement was 281 seconds(20-593 sec) at the optimal dosage, which was of 2.4 ml of SonoVuetrade mark in nine patients. CD and SD signal enhancement (n = 20, CD + SD) was considered optimal in 12 of 20, excessive in 1 of 20, and moderate or insufficient in 5 of 20 and 2 of 20 cases, respectively. There was a tendency for superior improvement in CD signal enhancement. Diagnostic confidence was improved in 8 of 10 cases without false diagnostic conclusions. SonoVuetrade mark has been demonstrated to be a powerful and safe echo signal enhancing agent, which significantly improves transcranial and extracranial ultrasound investigations and increases the confidence in diagnosis.

Journal Article↗