A new closed-loop control system for isoflurane using bispectral index outperforms manual control.

BACKGROUND: Automatic control of depth of hypnosis using the Bispectral Index (BIS) can help to reduce phases of inadequate control. Automated BIS control with propofol or isoflurane administration via an infusion system has recently been described, a comparable study with isoflurane administration via a vaporizer had not been conducted yet. Our hypothesis was that our new model based closed-loop control system can safely be applied clinically and maintains the BIS within a defined target range better than manual control. METHODS: Twenty-three patients, American Society of Anesthesiologists risk class I-III, scheduled for decompressive spinal surgery were randomized into groups with either closed-loop or manual control of BIS using isoflurane. An alfentanil target-controlled infusion was adjusted according to standard clinical practice. The BIS target was set to 50 during the operation. The necessity of human intervention in the control system and events of inadequate sedation (BIS <40 or BIS >60) were counted. The number of phases of inadequate control, defined as BIS >/=65 for more than 3 min, were recorded. The performance of the controller was assessed by several indicators (mean absolute deviation and median absolute performance error) and measured during the skin incision phase, the subsequent low flow phase, and the wound closure phase. Recovery profiles of both groups were compared. RESULTS: No human intervention was necessary in the closed-loop control group. The occurrence of inadequate BIS was quantified with the mean and median values of the area under the curve and amounted to 0.360 and 0.088 for the manual control group and 0.049 and 0.017 for the closed-loop control group, respectively. In the manual control group nine phases of inadequate control were recorded, compared with one in the closed-loop control group, 10.3% to 0.5% of all observed anesthesia time. During all phases the averages of the performance parameters (mean absolute deviation and median absolute performance error) were more than 30% smaller in closed-loop control than in manual control (P < 0.05 between groups). CONCLUSIONS: Closed-loop control with BIS using isoflurane can safely be applied clinically and performs significantly better than manual control, even in phases with abrupt changes of stimulation that cannot be foreseen by the control system.

Adolescent↗

Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler.

OBJECTIVE: To compare two methods of assessing a change in stroke volume in response to fluid challenge: esophageal Doppler and thermodilution with the pulmonary artery catheter. DESIGN: Prospective study. SETTING: Department of Intensive Care of a university medical center. PATIENTS: 19 adult patients, intubated and sedated, with a pulmonary catheter and a clinical indication for a fluid challenge. INTERVENTIONS: Two examiners independently assessed the effect of a fluid challenge on stroke volume and cardiac output with esophageal Doppler. Thermodilution performed by an independent clinician was used as the reference. Between-method variation and interobserver variability of the Doppler method were assessed. MEASUREMENTS AND RESULTS: There were no differences in stroke volume and cardiac output before volume challenge when measured with either of the two methods or by the two examiners using the esophageal Doppler. Despite a small bias between the methods and the two examiners using the esophageal Doppler (overall bias for cardiac output 0.3 l/min), the precision was poor (1.8 l/min). CONCLUSIONS: The esophageal Doppler method is a non-invasive alternative to the pulmonary artery catheter for the assessment of stroke volume in critically ill patients. Measurement of stroke volume response to fluid challenge using esophageal Doppler shows substantial interobserver variability. Despite the poor precision between methods and investigators, similar directional changes in stroke volume can be measured.

Adult↗