A cost-effectiveness analysis of a hypothetical catheter-based strategy for the detection and treatment of vulnerable coronary plaques with drug-eluting stents.

AIM: Extensive efforts are underway to develop methods for the detection and treatment of vulnerable/high-risk coronary artery plaques. We utilized decision analysis to evaluate the hypothetical clinical benefits and cost-effectiveness of a catheter-based strategy. METHODS AND RESULTS: Currently, stenotic coronary plaques are treated without regard to vulnerability. In a new strategy, vulnerable coronary plaques are detected with a catheter-based test and treated with a drug-eluting stent, regardless of degree of stenosis. A Markov-decision model was developed to compare the new strategy with current practice. Monte Carlo simulations were performed from a societal perspective, costs were converted to year 2003 U.S. dollars, and future costs and outcomes were discounted at 3%. Sensitivity analyses were performed to evaluate the effect of assumptions on variables such as the prevalence of vulnerable plaques and treatment effect. In 60-year-old male patients with coronary stenoses the new strategy would be less expensive and more effective than current practice (37,045 dollars vs 38,257 dollars and 10.23 vs 9.86 quality-adjusted life years (QALYs), respectively). The benefits of the new strategy were robust in sensitivity analyses (e.g., if the prevalence of vulnerable plaques in this patient group was 50% or more and the sensitivity and specificity of the new test were at least 0.80). CONCLUSION: In selected patients with coronary artery stenosis, the detection of vulnerable plaques with a catheter-based test followed by their treatment with a drug-eluting stent could be a less expensive and more effective strategy than current practice. If applied to 1 million such patients in the United States undergoing catheterization, the new strategy would add 370,000 QALYs and save 1.2 billion dollars per year.

Blood Vessel Prosthesis Implantation↗

Experimental flat-panel high-spatial-resolution volume CT of the temporal bone.

BACKGROUND AND PURPOSE: A CT scanner employing a digital flat-panel detector is capable of very high spatial resolution as compared with a multi-section CT (MSCT) scanner. Our purpose was to determine how well a prototypical volume CT (VCT) scanner with a flat-panel detector system defines fine structures in temporal bone. METHODS: Four partially manipulated temporal-bone specimens were imaged by use of a prototypical cone-beam VCT scanner with a flat-panel detector system at an isometric resolution of 150 microm at the isocenter. These specimens were also depicted by state-of-the-art multisection CT (MSCT). Forty-two structures imaged by both scanners were qualitatively assessed and rated, and scores assigned to VCT findings were compared with those of MSCT. RESULTS: Qualitative assessment of anatomic structures, lesions, cochlear implants, and middle-ear hearing aids indicated that image quality was significantly better with VCT (P < .001). Structures near the spatial-resolution limit of MSCT (e.g., bony covering of the tympanic segment of the facial canal, the incudo-stapedial joint, the proximal vestibular aqueduct, the interscalar septum, and the modiolus) had higher contrast and less partial-volume effect with VCT. CONCLUSION: The flat-panel prototype provides better definition of fine osseous structures of temporal bone than that of currently available MSCT scanners. This study provides impetus for further research in increasing spatial resolution beyond that offered by the current state-of-the-art scanners.

Artifacts↗

Jail-based substance user treatment: an analysis of retention.

Many jail inmates have a history of substance use and "abuse"; few, however, receive comprehensive treatment for substance use disorders while in jail. The authors offer a longitudinal reanalysis of data from five jail-based substance user treatment programs. Survival analysis was used to identify client characteristics associated with length of time in treatment. Survival curves for the five programs were compared, indicating which ones retained inmates the longest. Results from a model stratified by jail site revealed that inmates over 25 years of age and those already sentenced had significantly longer treatment stays. The Substance Abuse Intervention Division (SAID) program, a modified therapeutic community in a New York jail, and the Deciding, Educating, Understanding, Counseling, and Evaluation (DEUCE) program, a curriculum-based intervention, had the longest survival curves and were, therefore, most effective at retaining inmates in treatment.

Adult↗

Phospholipid-bound molecular rotors: synthesis and characterization.

Molecular rotors are fluorescent molecules with a viscosity-sensitive quantum yield that are often used to measure viscosity changes in cell membranes and liposomes. However, commercially available molecular rotors, such as DCVJ (1) do not localize in cell membranes but rapidly migrate into the cytoplasm leading to unreliable measurements of cell membrane viscosity. To overcome this problem, we synthesized molecular rotors covalently attached to a phospholipid scaffold. Attaching the rotor group to the hydrophobic end of phosphatidylcholine (PC) did not affect the rotor's viscosity sensitivity and allowed adequate integration into artificial bilayers as well as complete localization in the plasma membrane of an endothelial cell line. Moreover, these new rotors enabled the monitoring of phospholipid transition temperature. However, attachment of the rotor groups to the hydrophilic head of the phospholipid led to a partial loss of viscosity sensitivity. The improved sensitivity and exclusive localization in the cell plasma membrane exhibited by the phospholipid-bound molecular rotors suggest that these probes can be used for the study of membrane microviscosity.

Cell Line↗

A novel approach to blood plasma viscosity measurement using fluorescent molecular rotors.

Molecular rotors, a group of fluorescent molecules with viscosity-dependent quantum yield, were tested for their suitability to act as fluorescence-based plasma viscometers. The viscosity of samples of human plasma was modified by the addition of pentastarch (molecular mass 260 kDa, 10% solution in saline) and measured with a Brookfield viscometer. Plasma viscosity was 1.6 mPa x s, and the mixtures ranged up to 4.5 mPa x s (21 degrees C). The stimulated light emission of the molecular rotors mixed in the plasma samples yielded light intensity that was nonoverlapping and of significantly different intensity for viscosity steps down to 0.3 mPa x s (n = 5, P < 0.0001). The mathematical relationship between intensity (I) and viscosity (eta) was found to be eta = (kappaI)(nu). After calibration and scaling the fluorescence based measurement had an average deviation versus the conventional viscometric measurements that was <1.8%. These results show the suitability of molecular rotors for fast, low-volume biofluid viscosity measurements achieving accuracy and precision comparable to mechanical viscometers.

Blood Viscosity↗

Evaluation of retrospective multisector and half scan ECG-gated multidetector cardiac CT protocols with moving phantoms.

PURPOSE: We evaluated independently retrospective half scan and multisector mode manufacturer's protocols and compared them with modified acquisition protocols to determine optimal imaging parameters for cardiac scanning. MATERIALS AND METHODS: Data were acquired using two fabricated gated moving phantoms. In half scan mode, the manufacturer's recommended pitch values were compared with adjacent values at different motion rates. In multisector mode, the manufacturer's protocols were compared with ones with different gantry speeds and pitch values at the same motion rates. Weighted CT dose indexes (CTDI) were obtained for all protocols. Gated and reformatted reconstructed images of the moving phantoms were evaluated. RESULTS: In half scan mode, slightly better image quality was observed by lowering the pitch value, but with an increase of 6.3% of the weighted CTDI. Better results were obtained in multisector mode by lowering the pitch value up to 0.2, but with an increase of 14.3% of the weighted CTDI. Optimal images were obtained with the lowest temporal resolution. CONCLUSIONS: Gated moving phantom studies offer the advantage of testing acquisition protocols of complex motions and of helping to establish appropriate protocols.

Electrocardiography↗