PubMed Health⌕ Search

Biomedical subjects

Thomas C Lauenstein

Publications and source records attributed to Thomas C Lauenstein.

At least 19 recordsLinked to original sources

MR colonography: current status.

Magnetic resonance colonography (MRC) has gained access into clinical routine as a means for the assessment of the large bowel. There are widely accepted indications for MRC, especially in patients with incomplete conventional colonoscopy. Furthermore, virtual MRC is more and more propagated as a screening tool, with advantages especially inherent to the non-invasive character of this procedure and the lack of ionizing radiation exposition. Beyond a sufficiently high diagnostic accuracy, outstanding patient acceptance is a major advantage of MRC as a diagnostic modality. This review article describes indications, techniques and clinical outcome of current MRC approaches. Furthermore, the impact of fecal tagging concepts is discussed.

Colon↗

MR colonography for the assessment of colonic anastomoses.

PURPOSE: To assess colonic anastomoses in patients after surgical treatment by means of MR colonography (MRC) in comparison with conventional colonoscopy (CC). MATERIALS AND METHODS: A total of 39 patients who had previously undergone colonic resection and end-to-end-anastomosis were included in the study. MRI was based on a dark-lumen approach. Contrast-enhanced T1-weighted (T1w) three-dimensional (3D) images were collected following the rectal administration of water for colonic distension. The MRC data were evaluated by two radiologists. The criteria employed to evaluate the anastomoses included bowel wall thickening and increased contrast uptake in this region. Furthermore, all other colonic segments were assessed for the presence of pathologies. RESULTS: In 23 and 20 patients the anastomosis was rated to be normal by MRC and CC, respectively. In three patients CC revealed a slight inflammation of the anastomosis that was missed by MRI. A moderate stenosis of the anastomosis without inflammation was detected by MRC in five patients, which was confirmed by CC. In the remaining 11 patients a relevant pathology of the anastomosis was diagnosed by both MRC and CC. Recurrent tumor was diagnosed in two patients with a history of colorectal carcinoma. In the other nine patients inflammation of the anastomosis was seen in seven with Crohn's disease (CD) and two with ulcerative colitis. MRC did not yield any false-positive findings, resulting in an overall sensitivity/specificity for the assessment of the anastomosis of 84%/100%. CONCLUSION: MRC represents a promising alternative to CC for the assessment of colonic anastomoses in patients with previous colonic resection.

Adult↗

Magnetic resonance imaging of experimental atherosclerotic plaque: comparison of two ultrasmall superparamagnetic particles of iron oxide.

PURPOSE: To evaluate a new ultrasmall superparamagnetic particles of iron oxide (USPIO) compound, ferumoxytol, as a marker of macrophage activity in atherosclerotic plaques and to compare it to ferumoxtran-10. MATERIALS AND METHODS: Ten mature heritable hyperlipidemic (WHHL) female Watanabe rabbits served as the animal model for atherosclerosis, four coeval female New Zealand White (NZW) rabbits were the control group. Five WHHL and two NZW received a single intravenous injection (250 micromol/kg) of either ferumoxtran-10 or ferumoxytol and were subjected to daily MR examinations on a 1.5T whole body scanner for the next five days. Development of signal intensity changes and susceptibility effects was assessed. Statistical analysis was based on a nonparametric Wilcoxon-Mann-Whitney-U test by using a P value at the 0.05 significance level. On day 5, the rabbits were sacrificed and the aorta was referred to histopathology, distribution of iron particles in the vessel wall was analyzed. RESULTS: MRI was feasible in all animals. Three days after injection of ferumoxytol the highest luminal signal intensity measurements were observed in the ferumoxytol group; the highest measurements were five days after injection in the ferumoxtran-10 group (P < 0.05). In the WHHL, susceptibility effects presented as homogeneous dark lines parallel to the aortic wall after ferumoxytol and spotted areas void of signal after ferumoxtran-10. None of these findings were observed in the NZW control groups. CONCLUSION: Ferumoxtran-10 and ferumoxytol at a respective dose of 250 mumol/kg appear well suited for atherosclerotic plaque detection with MRI in experimental atherosclerosis. Ferumoxytol warrants further analysis in humans.

Animals↗

Emerging techniques: whole-body screening and staging with MRI.

Strategies for screening or tumor staging include various modalities such as plain radiography, computed tomography (CT), MRI, and ultrasound. Technical innovations have created the feasibility to use MRI to image the entire body in a relatively short time-period. Whole-body MRI may play a potentially important role in evaluating for cancer or vascular disease. This article describes the rationale for using MRI to display the entire body, the techniques employed in whole-body MRI, possibilities and limitations, and summarizes first clinical results for screening and staging purposes.

Female↗

Hydro-MRI of the small bowel: effect of contrast volume, timing of contrast administration, and data acquisition on bowel distention.

OBJECTIVE: The purpose of this study was to assess oral contrast agents, volumes of the agents, and time points of data acquisition in regard to small-bowel distention and patient acceptance. SUBJECTS AND METHODS: Six healthy volunteers underwent imaging on 16 different days. Four volumes (450, 900, 1,350, and 1,800 mL) of each of the four contrast compounds (0.2% locust bean gum plus 2.5% mannitol, VoLumen containing 2.0% sorbitol, VoLumen containing 1.4% sorbitol, and tap water) were used. Two-dimensional true fast imaging with steady-state free precession data sets were acquired at 5-minute intervals after contrast ingestion. Distention values for small-bowel segments (duodenum, proximal and distal jejunum, ileum) and occurrence of side effects were documented. RESULTS: Analysis of bowel distention revealed significantly greater distention for all carbohydrate sugar alcohol-containing solutions compared with water but no significant difference among the three contrast agents. Sufficient duodenal distention was achieved with 900 mL of any of the contrast agents, but imaging had to be performed soon after ingestion. For MRI of the distal jejunum and ileum, a volume of 1,350 mL is preferable, and the time point of data acquisition plays a minor role. Ingestion of 1,800 mL of the carbohydrate sugar alcohol solutions led to a significantly higher rate of side effects such as abdominal cramps than did ingestion of smaller volumes. CONCLUSION: The data indicate that sufficient contrast consumption and optimal timing of data acquisition are essential to distention of the small bowel. Oral contrast agent protocols should be adapted to the bowel region in question.

Administration, Oral↗

Magnetic resonance colonography without bowel cleansing using oral and rectal stool softeners (fecal cracking)--a feasibility study.

The aim of our study was to assess the effect of oral and rectal stool softeners on dark-lumen magnetic resonance (MR) colonography without bowel cleansing. Ten volunteers underwent MR colonography without colonic cleansing. A baseline examination was performed without oral or rectal administration of stool softeners. In a second set, volunteers ingested 60 ml of lactulose 24 h prior to MR examination. In a third examination, water as a rectal enema was replaced by a solution of 0.5%-docusate sodium (DS). A fourth MR examination was performed, in conjunction with both oral administration of lactulose and rectal application of DS. A T1-weighted data set was acquired at scanning times of 0, 5 and 10 min after colonic filling. A fourth data set was acquired 75 s after i.v. injection of contrast agent. Signal intensity of stool was calculated for all colonic segments. Without oral ingestion of lactulose or rectal enema with DS stool signal intensity was high and did not decrease over time. However, lactulose and DS caused a decrease in stool signal intensity. Both substances together led to a decreasing signal intensity of feces. Combination of lactulose and DS provided the lowest signal intensity of stool. Thus, feces could hardly be distinguished from dark rectal enema allowing for the assessment of the colonic wall.

Administration, Oral↗

Evaluation of steady state free precession imaging of the pancreas.

The aim of this work was to assess the diagnostic value of fast steady state free precession (SSFP) for the detection, characterization, and delineation of pancreatic lesions. Forty-eight patients referred for magnetic resonance (MR) imaging of the pancreas were included in the study. In addition to the standard protocol, axial pre-contrast SSFP slices of the pancreas were acquired. The standard of reference was defined as based on all imaging data other than SSFP, histopathology, surgery, and/or clinical follow-up. A randomized consensus reading of the SSFP data sets was retrospectively conducted by two board-certified radiologists. The presence of pancreatic lesions, local infiltration, and lymph node metastases was evaluated. Sensitivity and specificity were calculated and a receiver operating characteristic (ROC) analysis was performed. The overall sensitivity and specificity of SSFP were 0.93 and 0.77, respectively. Comparable values were achieved for lymph node detection (0.88/0.91) and assessment of vascular infiltration (0.94/0.91). The mean area under the ROC curve (Az) was 0.91. Owing to its potential to detect vascular infiltration and the rapid acquisition time, SSFP imaging should be supplemented as part of a standard MR protocol of the pancreas.

Contrast Media↗

Oral contrast agents for small bowel distension in MRI: influence of the osmolarity for small bowel distention.

To assess the effect of the osmolarity for small bowel distension in MRI, ten volunteers ingested at two separate occasions negative oral contrast agents with different quantity and osmolarity: (1) a water solution combined with 2.0% sorbitol and 0.2% locus bean gum (LBG) with a quantity of 1500 ml and an osmolarity of 148 mOsmol/l, (2) a water solution combined with 2.0% sorbitol and 2.0% barium sulphate with a quantity of 1000 ml and an osmolarity of 194 mOsmol/l. Small bowel distension was quantified on coronal 2D-TrueFISP images by measuring the small bowel diameters. There were no statistically significant differences in mean small bowel diameter between both contrast agents. The mean small bowel distension was 19.2 mm after ingestion of 1500 ml of sorbitol-LBG solution and 19.0 mm after ingestion of 1000-ml sorbitol-barium sulphate solution. Furthermore, all volunteers found the ingestion of 1000-ml solution more pleasant than the 1500-ml solution. The ingestion of 1000 ml of sorbitol-barium sulphate solution led to a sufficient small bowel distension compared to 1500 ml of sorbitol-LBG solution. The side effect rate of both solutions was low. Based on these data, we recommend a quantity of 1000 ml of sorbitol-barium sulphate solution as an alternative for 1500-ml sorbitol-LBG solution for optimal bowel distension.

Administration, Oral↗

Digital subtraction dark-lumen MR colonography: initial experience.

PURPOSE: To evaluate image subtraction for the detection of colonic pathologies in a dark-lumen MR colonography exam. MATERIALS AND METHODS: A total of 20 patients (12 males; 8 females; mean 51.4 years of age) underwent MR colonography after standard cleansing and a rectal water enema on a 1.5-T whole-body MR system. After suppression of peristaltic motion, native and Gd-contrast-enhanced three-dimensional T1-w gradient echo images were acquired in the coronal plane. Two radiologists analyzed the MR data sets in consensus on two separate occasions, with and without the subtracted images for lesion detection, and assessed the value of the subtracted data set on a five-point Likert scale (1=very helpful to 5=very unhelpful). All imaging results were compared with endoscopy. RESULTS: Without subtracted images, MR-colonography detected a total of five polyps, two inflammatory lesions, and one carcinoma in eight patients, which were all verified by endoscopy. Using subtraction, an additional polyp was found, and readout time was significantly shorter (6:41 vs. 7:39 minutes; P<0.05). In two patients, endoscopy detected a flat adenoma and a polyp (0.4 cm) that were missed in the MR exam. Sensitivity and specificity without subtraction were 0.67/1.0, and 0.76/1.0 with the subtracted images, respectively. Subtraction was assessed as helpful in all exams (mean value 1.8+/-0.5; Likert scale). CONCLUSION: We consider subtraction of native from contrast-enhanced dark-lumen MR colonography data sets as a beneficial supplement to the exam.

Adult↗

Small bowel hydro-MR imaging for optimized ileocecal distension in Crohn's disease: should an additional rectal enema filling be performed?

PURPOSE: To assess the impact of an additional rectal enema filling in small bowel hydro-MRI in patients with Crohn's disease. MATERIALS AND METHODS: A total of 40 patients with known Crohn's disease were analyzed retrospectively: 20 patients only ingested an oral contrast agent (group A), the other 20 subjects obtained an additional rectal water enema (group B). For small bowel distension, a solution containing 0.2% locust bean gum (LBG) and 2.5% mannitol was used. In all patients, a breathhold contrast-enhanced T1w three-dimensional volumetric interpolated breathhold examination (VIBE) sequence was acquired. Comparative analysis was based on image quality and bowel distension as well as signal-to-noise ratio (SNR) measurements. MR findings were compared with those of conventional colonoscopy, as available (N = 25). RESULTS: The terminal ileum and rectum showed a significantly higher distension following the rectal administration of water. Furthermore, fewer artifacts were seen within group B. This resulted in a higher reader confidence for the diagnosis of bowel disease, not only in the colon, but also in the ileocecal region. Diagnostic accuracy in diagnosing inflammation of the terminal ileum was 100% in group B; in the nonenema group there were three false-negative diagnoses of terminal ileitis. CONCLUSION: Our data show that the additional administration of a rectal enema is useful in small bowel MRI for the visualization of the terminal ileum. The additional time needed for the enema administration was minimal, and small and large bowel pathologies could be diagnosed with high accuracy. Thus, we suggest that a rectal enema in small bowel MR imaging be considered.

Adult↗

Virtual colonoscopy by MRI: state-of-the-art and future directions.

MR colonography has been shown to be an appropriate diagnostic tool for the detection of colorectal lesions. The technique is based on the acquisition of T1-weighted sequences after the administration of water enema and the intravenous administration of paramagnetic contrast. This article describes the technical requirements for MR colonoscopy and the procedures of data acquisition and image interpretation. The advantages and drawbacks of MR colonoscopy also are outlined.

Colonic Polyps↗

MR imaging of the large bowel.

MR colonography (MRC) is an accurate diagnostic tool for the detection of colorectal masses and inflammatory diseases. This article describes the underlying techniques of MRC that concern data acquisition and image interpretation. Indications for MRC are discussed, and technical developments are explained.

Colonic Diseases↗

Whole-body MRI for staging patients with head and neck squamous cell carcinoma.

CONCLUSIONS: Whole-body MRI is feasible for the tumor staging of patients with malignant head and neck tumors and appears to be a quick, reliable and proven alternative in general and for patients with contraindications to CT. This examination minimizes the logistical effort required compared to multimodality strategies. Its economic impact remains to be determined. OBJECTIVE: To assess the performance of whole-body MRI for staging patients with squamous cell carcinoma of the head and neck region. MATERIAL AND METHODS: This was a randomized, prospective clinical study. For tumor staging, 21 patients (mean age 56.7 years; range 43-80 years) with advanced malignant head and neck tumors underwent whole-body MRI in addition to routinely performed imaging investigations, including sonography, chest X-ray, CT of the head, neck and thorax and endoscopy. All investigations were accomplished within a period of 10+/-3 days in a random order. A randomized, blinded, consensus assessment of all the whole-body MRI examinations was performed by two radiologists. The localization and extent of the primary tumor and metastases were documented for whole-body MRI and compared to the standard of reference (all other imaging modalities as well as histology). Point estimates of the diagnostic accuracy of whole-body MRI were calculated. RESULTS: In accordance with the standard of reference, the overall TNM category was correctly determined with whole-body MRI in all 21 patients. However, four patients were classified as having carcinoma of unknown primary, as the primary tumor was not found with any imaging modality. Two patients had mediastinal, pulmonary and hepatic metastases.

Adult↗

Magnetic resonance colonography: comparison of contrast-enhanced three-dimensional vibe with two-dimensional FISP sequences: preliminary experience.

PURPOSE: The purpose of this study was to compare a dark-lumen magnetic resonance colonography (MRC) approach with a True FISP-based bright-lumen technique concerning presence of artifacts and the detection rate of colorectal pathologies. MATERIALS AND METHODS: Thirty-seven patients with suspected colorectal lesions were included in this trial. The colon was filled with 2500 mL of tap water. Two-dimensional True FISP datasets as well as T1-weighted GRE sequences (pre- and post intravenous contrast) were acquired. The detection rate of colorectal masses and inflammatory lesions was determined for both techniques separately. Besides, image quality was assessed. All patients underwent conventional colonoscopy as the standard of reference. RESULTS: By means of dark-lumen MRC datasets, all polyps >5 mm were correctly diagnosed, whereas 4 polyps <5 mm were missed. Sensitivity of dark-lumen MRC amounted to 78.9%. There were no false-positive results: residual stool could correctly be differentiated from colorectal masses. The True FISP-based bright-lumen MRC, however, failed to detect 2 additional polyps resulting in a sensitivity of 68.4%. Furthermore, bright-lumen MRC led to false-positive results in 5 patients. Both techniques visualized inflammatory bowel disease in 5 patients. However, image quality of True FISP was rated superior to that of dark-lumen MRC. CONCLUSION: Dark-lumen MRC proved to be superior over bright-lumen MRC regarding the detection of colorectal masses. However, True FISP imaging can turn out to be helpful as a result of high image quality and motion insensitivity.

Adolescent↗

Whole-body magnetic resonance imaging.

Whole-body magnetic resonance imaging is a fast and accurate modality for the detection of disease throughout the entire body. Technical improvements including the availability of different high image quality MR sequences, the remote movement of the imaging table, and the use of specialized surface coils have rendered whole-body screening with MRI a feasible method. In this article we describe underlying techniques and report on first clinical experiences of whole-body magnetic resonance imaging as a staging and screening method. Furthermore, advantages and limitations compared with whole-body imaging based on computed tomography are discussed.

Contrast Media↗

Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation.

OBJECTIVE: The purpose of our study was to quantify left ventricular function and mass derived from retrospectively ECG-gated 16-MDCT coronary angiography data sets using a new analysis software based on automatic contour detection in comparison to corresponding standard of reference measurements acquired with MRI. SUBJECTS AND METHODS: Multiplanar reformations in the short-axis orientation were calculated from axial contrast-enhanced CT images in 18 patients (men, 15; women, three; age range, 38-70 years; mean, 57.4 +/- 10.2 [SD] years) who were referred for CT coronary angiography. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed with a recently developed imaging software using an automated contour detection algorithm of left ventricular endo- and epicardial contours and by manual tracing. The data were compared with similar measurements on MRI as the standard of reference. RESULTS: EDV, ESV, EF, and LVM derived from an automated contour detection algorithm were not statistically significantly different from manual tracing (CT(auto) vs CT(manual): EDV = 137.1 +/- 45.7 mL vs 134.2 +/- 39.9 mL, ESV = 58.8 +/- 34.2 mL vs 58.1 +/-30.1 mL, EF = 59.2% +/- 13.7% vs 58.1% +/- 12.0%, LVM = 130.9 +/- 29.1 g vs 133.7 +/- 33.2 g; p > 0.05). However, EDV (118.7 +/- 43.6 mL), ESV (50.1 +/- 33.5 mL), and LVM (142.8 +/-38.4 g) as calculated on MR data sets were statistically significantly different from those calculated on CT (p < 0.05), whereas MRI-based EF (59.9% +/- 14.4%) did not differ statistically significantly from those based on both CT algorithms (p > 0.05). CONCLUSION: Automatic and manual analysis of data acquired during CT coronary angiography using a 16-MDCT scanner allows a reliable assessment of left ventricular ejection fraction and a rough estimation of left ventricular volumes and mass.

Adult↗

MR imaging of apparent small-bowel perfusion for diagnosing mesenteric ischemia: feasibility study.

The purpose of this study, which was approved by the institutional review board, was to assess the differentiation of individuals with from those without mesenteric ischemia. All subjects provided written informed consent. Six healthy volunteers and six patients with documented chronic mesenteric ischemia underwent magnetic resonance (MR) imaging with and without oral caloric stimulation. After intravenous administration of paramagnetic contrast material, signal intensity values of the small-bowel wall were measured up to 130 seconds after contrast material injection. Volunteers and patients, respectively, had maximum enhancement of the bowel wall between 70 and 85 seconds after contrast material administration that amounted to 269% and 267% without and 425% and 333% with caloric stimulation. MR imaging assessment of small-bowel perfusion is possible and seems feasible for differentiating individuals with from those without mesenteric ischemia.

Adult↗

MR colonography in patients with incomplete conventional colonoscopy.

PURPOSE: To assess dark-lumen magnetic resonance (MR) colonography for the evaluation of colonic segments in patients in whom conventional colonoscopy could not be completed. MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained. Within 24 hours of incomplete conventional colonoscopy, 37 patients (22 women, 15 men; age range, 25-63 years) underwent MR colonography. Contrast material-enhanced T1-weighted three-dimensional images were collected after rectal administration of water for colonic distention. Data from MR colonography were evaluated by two radiologists. With a three-point scale, image quality was characterized in terms of colonic distention (1 = good; 2 = moderate, diagnostic; and 3 = poor, nondiagnostic) and presence of artifacts (1 = none; 2 = moderate, diagnostic; and 3 = extensive, nondiagnostic). Depiction of colorectal disease was assessed according to the following colonic segments: cecum, ascending colon, transverse colon, descending colon, sigmoid colon, and rectum. RESULTS: Four patients had history of colorectal cancer, and each had undergone partial colonic resection of two segments. Hence, 214 segments were evaluated. Conventional colonoscopy failed in assessment of 127 of 214 potentially visible colonic segments in the 37 patients. MR image quality was rated diagnostic in 35 patients and permitted assessment of 206 of 214 potentially visible segments. Nondiagnostic image quality in two patients was attributed to inadequate distention of prestenotic colonic segments owing to high-grade tumor stenosis. All inflammation- and tumor-induced stenoses and all five polyps identified at conventional colonoscopy in poststenotic segments were correctly detected at MR colonography. However, MR-based assessment of prestenotic segments revealed two lesions suspected of being carcinoma, five polyps, and four segments affected by colitis. CONCLUSION: MR colonography proved reliable in evaluating the majority of colonic segments inaccessible with conventional colonoscopy. The identification of additional disease at MR colonography underscores the need for a second diagnostic step in the setting of incomplete conventional colonoscopy.

Adult↗