Multiple-electrode radiofrequency ablation creates confluent areas of necrosis: in vivo porcine liver results.

PURPOSE: To prospectively evaluate, in vivo in pigs, an impedance-based multiple-electrode radiofrequency (RF) ablation system for creation of confluent areas of hepatic coagulation. MATERIALS AND METHODS: The study was preapproved by the institutional research animal care and use committee. A prototype multiple-electrode RF system that enables switching between three electrically independent electrodes at impedance spikes was created. Forty-two coagulation zones (18 with single, 12 with cluster, and 12 with multiple [three single electrodes spaced 2 cm apart] electrodes) were created at laparotomy in 15 female pigs. Half the ablations were performed for 12 minutes, and half were performed for 16 minutes. The coagulation zones were excised and sliced into approximately 3-mm sections for measurement. Analysis of variance and two-sample t tests (with Bonferroni correction, alpha = .0033) were used to assess for differences between groups. RESULTS: At 12 minutes, the mean multiple-electrode coagulation was significantly larger than the mean single-electrode coagulation (minimum diameter, 2.8 vs 1.6 cm; maximum diameter, 4.2 vs 2.0 cm; volume, 22.1 vs 6.7 cm(3); P < .0033 for all comparisons). The mean maximum diameter achieved at 12 minutes with multiple electrodes was significantly larger than that achieved with the cluster electrode (4.2 vs 2.9 cm, P = .02). At 16 minutes, the mean multiple-electrode coagulation (minimum diameter, 3.2 cm; maximum diameter, 4.2 cm; volume, 29.1 cm(3)) was significantly larger than the mean single-electrode (minimum diameter, 1.7 cm; maximum diameter, 2.2 cm; volume, 7.1 cm(3); P < .0033 for all comparisons) and cluster-electrode (minimum diameter: 2.3 cm, P = .007; maximum diameter: 3.2 cm, P = .005; volume: 13.1 cm(3), P = .001) coagulations. CONCLUSION: Compared with the single and cluster systems used as controls, the multiple-electrode RF ablation system enabled the creation of significantly larger coagulation zones.

Animals↗

Focal tumor ablation: a new era in cancer therapy.

This article describes an approach to image-guided tumor ablation, a major tool for cancer treatment in interventional oncology. An overview of the discipline of tumor ablation is followed by a review of the diseases affecting the liver; then, more in-depth discussion of percutaneous ethanol injection, radiofrequency ablation, cryoablation, and microwave ablation is offered. Inasmuch as ultrasound is usually the best imaging modality for applicator placement in the liver and kidney, particular attention will be given to the merits and techniques of this guidance method.

Administration, Cutaneous↗

Unintended thermal injuries from radiofrequency ablation: protection with 5% dextrose in water.

OBJECTIVE: Radiofrequency ablation of hepatic tumors can lead to thermal injury of surrounding structures. Both saline and 5% dextrose in water (D5) have been used to displace these surrounding structures before radiofrequency ablation. The purpose of this study was to determine the relative effectiveness of these two fluids for protecting the diaphragm and lung during radiofrequency ablation. MATERIALS AND METHODS: Ten female domestic swine (mean weight, 45 kg) underwent radiofrequency ablation at open surgery. Group 1 (n = 12 lesions) was pretreated with peritoneal D5 before radiofrequency ablation. Group 2 (n = 11 lesions) was pretreated with peritoneal 0.9% saline. A 2.7-mm spacer was placed between the liver surface and diaphragm in groups 1 and 2. Group 3 (n = seven lesions) served as a control group with no pretreatment regimen. Group 4, an additional control group (n = eight lesions), consisted of animals pretreated with D5 in which a larger spacer was used. After radiofrequency ablation, the animals were sacrificed and the liver, diaphragm, and lung were removed. The extent of thermal injury to the surface of each organ was recorded. RESULTS: The animals in the D5 and saline pretreatment groups experienced fewer diaphragm injuries than the control animals (D5, p = 0.02). The smallest lesions in the lung and diaphragm were in the D5 group, followed by the saline and control groups (diaphragm, p = 0.0001; lung, p = 0.13). Diaphragm lesions were significantly smaller in the D5 and saline groups than in the control group (p = 0.0001 and 0.01, respectively). CONCLUSION: Instillation of D5 into the peritoneal cavity before hepatic radiofrequency ablation decreases the risk and severity of diaphragm and lung injuries compared with no pretreatment or pretreatment with 0.9% saline in this animal model. Pretreatment with D5 may increase both the safety of and the number of patients eligible for treatment with thermal therapies.

Animals↗

Radiofrequency ablation of peripheral liver tumors: intraperitoneal 5% dextrose in water decreases postprocedural pain.

OBJECTIVE: Our objective was to evaluate the clinical efficacy of the intraperitoneal instillation of 5% dextrose in water (D5W) during radiofrequency ablation of peripheral liver tumors for decreasing postradiofrequency pain and narcotic use. MATERIALS AND METHODS: This case-control study compared the hospital course of the last 20 patients to undergo radiofrequency ablation of peripheral liver tumors at our institution. Ten consecutive subjects in the D5W group (seven women and three men; age range, 37-78 years; mean, 58 years) were pretreated with intraperitoneal D5W (average, 963 +/- 436 [SD] mL) before the ablation. This group was compared with a control group of 10 patients (five men and five women; age range, 36-73 years; mean, 54 years) who did not receive intraperitoneal D5W. The size of the ablation zone, degree of liver capsule involvement, number of burns, patient-reported pain, patient-controlled analgesia use, and length of hospital stay were recorded and compared between the groups. RESULTS: The patients in the D5W group reported significantly less pain in the first 24 hr after the procedure than did the controls (2.3 vs 6.3, p = 0.003) despite a significant decrease in patient-controlled analgesia use (17.3 vs 125.1 mg of morphine, p = 0.003). The differences in pain and patient-controlled analgesia use were greatest in the first 16 hr and decreased over time in both groups. The total volume of ablation (61.9 vs 45.2 cm(3), p = 0.44), liver surface involvement (6.2 vs 6.0 cm, p = 0.73), and number of burns (1.8 vs 1.1, p = 0.14) were slightly higher in the D5W group than in the control group, but this difference was not statistically significant. CONCLUSION: Pretreatment with intraperitoneal D5W before radiofrequency ablation of peripheral liver tumors decreased pain, narcotic use, and length of hospital stay. The effect of pretreatment with D5W is greatest in the first 16 hr after the procedure.

Adult↗

Polyp volume versus linear size measurements at CT colonography: implications for noninvasive surveillance of unresected colorectal lesions.

OBJECTIVE: Proposed surveillance of unresected medium-sized (6.0-9.9 mm) polyps will require reliable detection of small incremental changes. The purpose of this study was to assess the reproducibility of linear versus volume measurements of polyp size at CT colonography (CTC) and to correlate results with a hemispheric model. MATERIALS AND METHODS: The study group consisted of 30 polyps on supine and prone CTC data sets. Measurements were performed separately by two experienced radiologists using the same CTC system (Vitrea 2), resulting in 120 linear and volume measurements. Linear size was defined as the longest dimension among the 2D multiplanar reconstruction views. Semiautomated volume determination required manual tracing of polyp boundaries on 2D multiplanar reconstruction views. The relative error between reviewers 1 and 2 was defined as 100 x (/D1 - D2/)/D(ave) for linear size (D) and as 100 x (/V1 - V2)/V(ave) for volume (V), where ave is average. RESULTS: The mean relative error for linear size and volume measurement was 10.4% +/- 10.7% and 16.9% +/- 13.2%, respectively. Median linear size and volume of polyps were 9.4 mm and 270 mm3, respectively. CTC-derived volumes for medium-sized polyps closely approximated hemispheric volume (V = (pi/12) x D(b), where b =3.13, r2 = 0.90). Small incremental changes in hemispheric size result in a 3:1 relative change in volume versus diameter, such that a 1-mm diameter change in a medium-sized hemispheric polyp results in a relative change in linear size and volume ranging from approximately 11-18% and 31-53%, respectively. CONCLUSION: Because changes in polyp volume are amplified compared with linear dimension, volume measurement rather than diameter measurement will better allow detection of small incremental changes in polyp size using CTC.

Colonic Polyps↗

Hysterosalpingography and sonohysterography: lessons in technique.

OBJECTIVE: The objectives of this article are to review the examination techniques for hysterosalpingography and saline infusion sonohysterography and to present practical tips to enhance physician performance and minimize patient discomfort during these procedures. CONCLUSION: Optimally performed hysterosalpingography and saline infusion sonohysterography can be relatively comfortable procedures for the patient that provide a great deal of useful diagnostic information.

Catheterization↗

Comparison of colonic transit between polyethylene glycol and water as oral contrast vehicles in the CT evaluation of acute appendicitis.

OBJECTIVE: The objective of our study was to assess the efficacy of a new positive oral contrast agent's ability to reach the colon during CT evaluation of acute appendicitis. SUBJECTS AND METHODS: Eighty adult emergency department patients who underwent abdominal CT to evaluate for appendicitis were studied. Forty patients received the department's standard dose of 1,600 mL of a water-iodinated contrast mixture (ratio of 2 mL of iodinated contrast material to 100 mL of water) with a standard delay time of 2-2.5 hours from the beginning of contrast medium ingestion. Forty patients were given a new oral contrast mixture of 1,000 mL of polyethylene glycol (PEG) mixed with 30 mL of iodinated contrast agent, and the examination was conducted only 1 hour from inception of contrast administration. Examinations were reviewed for the presence of contrast medium in the cecum and the presence of appendicitis or other abdominal abnormality. RESULTS: Thirty-eight of 40 patients in the PEG group had contrast medium in the colon at 1 hour after contrast administration, 20 of whom had surgically confirmed cases of appendicitis. In five other patients in that group, another cause to explain the patient's complaints was identified on imaging. Only 18 of the 40 patients who received the standard oral preparation had contrast material present in the cecum. Eleven patients in that group had confirmed appendicitis, and four others had another abnormal finding detected at CT. There was a significant difference in the success of contrast medium transit to the colon with these two agents (p < 0.0001). CONCLUSION: The use of an oral contrast agent composed of PEG and iodinated contrast material provided a marked improvement in oral agent transit to the colon even in patients with intraabdominal inflammation.

Administration, Oral↗

Multiple-electrode radiofrequency ablation: simultaneous production of separate zones of coagulation in an in vivo porcine liver model.

PURPOSE: A multiple-electrode radiofrequency (RF) system was developed based on switching between electrodes that allows for the simultaneous use of as many as three electrically independent electrodes. The purpose of this study was to determine if each multiple-electrode ablation zone is identical to an ablation zone created with conventional single-electrode mode. MATERIALS AND METHODS: Nine female domestic pigs (mean weight, 90 kg) were used for this study. A prototype monopolar multiple-electrode RF ablation system was created with use of an RF generator and an electronic switching algorithm. A maximum of three electrodes can be used simultaneously by switching between electrodes at each impedance spike (30 omega greater than baseline levels). A total of 39 zones of ablation were created at open laparotomy in pig livers with use of a conventional single electrode (n = 9), two single electrodes simultaneously (n = 6 ablations; 12 ablation zones), or three single electrodes simultaneously (n = 6 ablations; 18 ablation zones). RF electrodes were spaced in separate lobes of the liver when multiple zones of coagulation were created simultaneously. Animals were euthanized after RF ablation, livers were removed, and ablation zones were sectioned and measured. RESULTS: Zones of coagulation created simultaneously with two or three electrodes were equivalent to ablation zones created with use of conventional single-electrode ablation. No significant differences were observed among control animals treated with a single electrode, those with two separate zones of ablation created simultaneously, and those with three simultaneously created ablation zones in terms of mean (+/-SD) minimum diameter (1.6 cm +/- 0.6, 1.6 cm +/- 0.5, and 1.7 cm +/- 0.4, respectively), maximum diameter (2.0 cm +/- 0.5, 2.3 cm +/- 0.5, 2.2 cm +/- 0.5, respectively), and volume (6.7 cm3 +/- 3.7, 7.4 cm3 +/- 3.8, and 7.8 cm3 +/- 3.9; P > .30, analysis of variance, pairwise t-test comparisons). CONCLUSIONS: A rapid-switching multiple-electrode RF system was able to simultaneously create as many as three separate ablation zones of equivalent size compared with single-electrode controls. This system would allow physicians to simultaneously treat multiple tumors, substantially reducing procedure time and anesthesia risk.

Algorithms↗

Hepatic hemorrhage caused by percutaneous tumor ablation: radiofrequency ablation versus cryoablation in a porcine model.

PURPOSE: To determine the extent of hepatic hemorrhage caused by percutaneous cryoablation performed with a small-diameter cryoablation probe compared with that caused by percutaneous radiofrequency (RF) ablation in a porcine model. MATERIALS AND METHODS: The study was pre-approved by the institutional research animal care and use committee, and husbandry and experiments complied with National Institutes of Health standards for care and use of laboratory animals. Percutaneous hepatic ablation was performed in 18 domestic pigs (mean weight, 45 kg) by using a 17-gauge (1.5-mm-diameter) RF electrode (n = 6), a cluster of three RF electrodes (n = 6), or a 13-gauge (2.4 mm-diameter) cryoprobe (n = 6). Ablation was performed in four sites per liver. Total blood loss, minimum lesion diameter, maximum lesion diameter, and lesion volume were determined for each group and compared by using analysis of variance. RESULTS: Mean blood loss was 11.11 mL +/- 11.47 (standard deviation), 105.29 mL +/- 175.58, and 28.06 mL +/- 30.97 with the single RF electrode, RF electrode cluster, and cryoablation probe, respectively. Mean minimum and maximum lesion diameters were largest with the RF electrode cluster (2.40 and 3.98 cm, respectively), followed by the cryoablation probe (2.38 and 3.94 cm) and single RF electrode (1.49 and 2.63 cm). Mean minimum and maximum lesion diameters were significantly different between the single RF electrode and the RF electrode cluster, as well as between the single RF electrode and the cryoablation probe (P < .001). Mean lesion volume was largest for the RF electrode cluster (24.03 cm3), followed by those for the cryoablation probe (17.46 cm3) and single RF electrode (9.05 cm3) (single RF electrode vs cryoablation probe, P < .05). Lesion volumes were not significantly different with the RF electrode cluster versus the single RF electrode (P = .052) or with the RF electrode cluster versus the cryoablation probe (P = .381). CONCLUSION: Mean blood loss from percutaneous cryoablation in this model was between that for RF ablation with the single electrode and that for RF ablation with the electrode cluster.

Analysis of Variance↗

Delineation and evaluation of hydrologic-landscape regions in the United States using geographic information system tools and multivariate statistical analyses.

Hydrologic-landscape regions in the United States were delineated by using geographic information system (GIS) tools combined with principal components and cluster analyses. The GIS and statistical analyses were applied to land-surface form, geologic texture (permeability of the soil and bedrock), and climate variables that describe the physical and climatic setting of 43,931 small (approximately 200 km2) watersheds in the United States. (The term "watersheds" is defined in this paper as the drainage areas of tributary streams, headwater streams, and stream segments lying between two confluences.) The analyses grouped the watersheds into 20 noncontiguous regions based on similarities in land-surface form, geologic texture, and climate characteristics. The percentage of explained variance (R-squared value) in an analysis of variance was used to compare the hydrologic-landscape regions to 19 square geometric regions and the 21 U.S. Environmental Protection Agency level-II ecoregions. Hydrologic-landscape regions generally were better than ecoregions at delineating regions of distinct land-surface form and geologic texture. Hydrologic-landscape regions and ecoregions were equally effective at defining regions in terms of climate, land cover, and water-quality characteristics. For about half of the landscape, climate, and water-quality characteristics, the R-squared values of square geometric regions were as high as hydrologic-landscape regions or ecoregions.

Climate↗

Microwave ablation with loop antenna: in vivo porcine liver model.

PURPOSE: To determine the effectiveness of tissue ablation with a loop microwave antenna in various configurations in porcine liver tissue. MATERIALS AND METHODS: Microwave energy was applied for 7 minutes at 60 W in six porcine livers (mean weight, 68.2 kg) by using single (n = 7) or dual 2.7-cm loop microwave probes in parallel (n = 9) or orthogonal (n = 9) configurations. Volume, diameter, shape, and temperature of the zone of necrosis and the presence of viable tissue inside the loop were determined and compared by means of factorial analysis of variance. RESULTS: Mean lesion volume and maximum diameter, respectively, were 32.2 cm(3) +/- 14.4 (SD) and 4.6 cm +/- 1.4 for lesions ablated with parallel probes (parallel lesions), 29.5 cm(3) +/- 8.1 and 4.3 cm +/- 0.6 for lesions ablated with orthogonal probes (orthogonal lesions), and 6.4 cm(3) +/- 1.9 and 3.4 cm +/- 0.62 for lesions ablated with single probes (single lesions) (P <.05, single vs parallel and orthogonal lesions). Mean minimum diameter was greatest for orthogonal lesions (3.5 cm +/- 0.53; P =.017, parallel vs orthogonal lesions). Orthogonal lesions had the highest mean internal temperature (97.2 degrees C) versus parallel (91.9 degrees C) and single (60.0 degrees C) lesions. All orthogonal lesions heated to 60 degrees C in comparison to eight of nine parallel and four of seven single lesions. The mean time to reach 60 degrees C was shortest for orthogonal lesions (93.3 seconds) versus parallel (123.8 seconds) and single (263.0 seconds) lesions. Orthogonal lesions were the most spherical. Viable tissue was present in the center of five of seven single, six of nine parallel, and zero of nine orthogonal lesions. CONCLUSION: Loop microwave antennas allow precise control and effective ablation of targeted tissue, particularly in the orthogonal configuration.

Animals↗

Saline infusion sonohysterography: technique, indications, and imaging findings.

OBJECTIVE: To review the technique, indications, and common imaging findings regarding saline infusion sonohysterography. METHODS: The literature on saline infusion sonohysterography was reviewed. Pertinent images from our institution are presented to illustrate common imaging findings. RESULTS: From the literature review, we summarize the various clinical scenarios in which saline infusion sonohysterography is useful and give examples from our clinical practice. CONCLUSIONS: Saline infusion sonohysterography is a useful procedure for evaluation of endometrial and subendometrial abnormalities.

Diagnosis, Differential↗

Testicular microlithiasis: clinical significance and review of the literature.

Testicular microlithiasis (TM) is an uncommon condition characterized by calcium deposits within the seminiferous tubules. On ultrasound (US), it is seen as multiple, uniform, nonshadowing echogenic foci in the testis. Although its true prevalence in the general population is still unknown, reported prevalences range from 0.6 to 9%. The TM is often associated with germ cell tumor (GCT) or intratubular germ cell neoplasia. The incidence of GCT in patients with TM was reported as 6-46%. There are several reports demonstrating interval development of GCT in patients with TM. These may suggest a premalignant nature of TM; however, more recent studies show a lower incidence of associated GCT and no interval development of tumor in relatively longer duration follow-up. Additionally, previously reported cases of interval tumor development had predisposing factors for testicular GCT. According to the recent literature, it is suggested that both TM and testicular GCT may be caused by a common defect, such as tubular degeneration, and TM may present as a marker for such abnormalities; however, because of a high incidence of association with GCT, it is prudent to follow up patients with TM with physical examination and US at least annually and to encourage self-examination. The routine use of biochemical tumor markers, abdominal and pelvic CT, or testicular biopsy does not seem to be justified.

Humans↗

Postbiopsy bleeding in a porcine model: reduction with radio-frequency ablation--preliminary results.

PURPOSE: To test a biopsy needle modified for use of radio-frequency (RF) energy to produce hemostasis after core biopsy of liver or kidney. MATERIALS AND METHODS: RF energy was applied to a partially insulated 17-gauge needle, and tip temperature was monitored with a thermocouple. Domestic Yorkshire pigs (n = 4; mean weight, 23.4 kg) were anesthetized, and their livers and kidneys were exposed. Needles were inserted 2 cm into hepatic and renal parenchyma and retracted, either with or without tract ablation to 65 degrees C, in normal tissue, animals treated with anticoagulants, and an animal with acute inferior vena caval occlusion to produce portal hypertension. Blood loss was assessed by weighing surgical sponges with blood from the puncture sites. Significant differences in blood loss between control and ablated biopsy specimens in each scenario were tested by using a Wilcoxon matched-pairs signed rank test. RESULTS: Mean blood loss for each group was as follows: In the liver, control biopsy specimens (n = 18) lost 0.30 g while ablated biopsy specimens lost 0.00044 g (P <.01), and control biopsy specimens treated with heparin (n = 26) lost 0.45 g while biopsy specimens treated with heparin and ablation lost 0.27 g (P =.03). For inferior vena caval occlusion, control biopsy specimens lost 1.23 g, while ablated biopsy specimens lost 0.00 g. In the kidney, control biopsy specimens (n = 28) lost 0.82 g, while ablated biopsy specimens lost 0.24 g (P =.01), and control biopsy specimens treated with heparin (n = 14) lost 1.04 g, while biopsy specimens treated with heparin and ablation lost 0.19 g (P =.02). CONCLUSION: Tract ablation with thermocouple-monitored RF energy decreased postprocedural hemorrhage after hepatic and renal biopsy.

Animals↗

Using a saline chaser to decrease contrast media in abdominal CT.

OBJECTIVE: The purpose of this study was to compare hepatic tumor conspicuity on CT after injection of either 150 mL of contrast material or 100 mL of contrast material plus a 50-mL saline chaser. SUBJECTS AND METHODS: We evaluated 86 hypoattenuating liver metastases in 26 patients. Patients underwent CT in two sessions separated by a mean of 85 days: one time with 150 mL of contrast material and the other time with 100 mL of contrast material followed by a 50-mL saline chaser. The order of the sessions was randomized. Contrast material was administered via power injector and matched for injection rate and delay time. Attenuation values were obtained from normal liver tissue and metastases and from the spleen, kidney, aorta, and inferior vena cava. RESULTS: The 150 mL dose of contrast material caused slightly greater liver and tumor attenuation than 100 mL of contrast material with a chaser (mean hepatic attenuation, 95.6 vs 89.8 H, respectively; p < 0.03, paired t test; mean tumor attenuation, 53.2 vs 49.1 H, respectively; r = 0.71, p = 0.09). The difference in conspicuity of liver lesions was slightly greater with 150 mL than with 100 mL with a chaser (46.8 H vs 44.2 H; r = 0.46, p = 0.08, paired t test), but was of doubtful clinical significance (2.6 H). Kidney, spleen, and vascular structures enhanced more with 150 mL than with 100 mL and a chaser. CONCLUSION: Using 100 mL of contrast material and a saline chaser did not result in a meaningful difference in liver parenchyma attenuation or lesion conspicuity compared with using 150 mL of contrast medium alone. Routine use of a chaser for abdominal CT may yield cost savings and a decreased risk of contrast nephropathy.

Adult↗