Thomas F Hany

Publications and source records attributed to Thomas F Hany.

28 records · Page 2Linked to original sources

Iatrogenic FDG foci in the lungs: a pitfall of PET image interpretation.

2-[F-18]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) has become an important staging modality for many tumors, including bronchial carcinoma; however it is important to know that there are several pitfalls in PET image interpretation. In this report we demonstrate three cases in which focal intrapulmonary FDG uptake could possibly represent iatrogenic microembolism. These FDG accumulations would have been interpreted as malignant tumor mass in the lung if no anatomic correlation would have been performed. For this reason, we further present an integrated PET/CT scanner, which recently has been introduced. This correlation of molecular and morphological information enables the specification of the FDG-PET findings.

Child↗

Brown adipose tissue: a factor to consider in symmetrical tracer uptake in the neck and upper chest region.

Increased symmetrical fluorine-18 fluorodeoxyglucose (FDG) uptake in the cervical and thoracic spine region is well known and has been attributed to muscular uptake. The purpose of this study was to re-evaluate this FDG uptake pattern by means of co-registered positron emission tomography (PET) and computed tomography (CT) imaging, which allowed exact localisation of this uptake. Between April and November 2001, 638 consecutive patients referred for PET/CT were imaged on an in-line PET/CT system (GEMS). This system combines an advanced GE PET scanner and a multirow-detector computer tomograph (Lightspeed, GEMS). The examination included PET with FDG and one CT acquisition with 80 mA. For CT, the following parameters were used: 140 kV, 80 mA, reconstructed slice thickness 5 mm, scan length 867 mm, AT 22.5 s. CT data were used for attenuation correction as well as image co-registration. Image analysis was performed on an Entegra work-station (ELGEMS). All patients with symmetrical uptake within the neck, thorax and shoulder regions were selected and the exact localisation of uptake determined (muscle, bone, fatty tissue or articulation). In 17 of the 638 patients (2.5%), increased, symmetrical FDG uptake in the shoulder region in a typical pattern was found. If extensive, this pattern included FDG activity comparable to brain activity in the lower cervical spine, the shoulder region and the upper thoracic spine in the costovertebral region. A less extensive pattern only involved intermediate FDG uptake in the lower cervical spine and shoulder region or in the shoulder region alone. In seven female patients (average 32.3 years), the extensive uptake pattern was seen. The average body mass index (BMI) was 19.0 (range 16.8-23.4). In the other ten patients (two male, eight female, average age 37.1 years), the average BMI was 22.7 (18.7-27.7). In all patients, the soft tissue uptake was clearly localised within the fatty tissue of the shoulders as demonstrated by PET/CT co-registration. The uptake in the region of the thoracic spine was localised in the region of the costovertebral joints. Symmetrical FDG uptake in the shoulder, neck and thoracic spine region is probably related to uptake in adipose tissue, especially in underweight patients. Hypothetically, this FDG uptake could represent activated brown adipose tissue during increased sympathetic nerve system (SNS) activity due to cold stress.

Adipose Tissue, Brown↗

Combined time-resolved and high-spatial-resolution 3D MRA using an extended adaptive acquisition.

PURPOSE: To combine the benefits of time-resolved dynamic imaging and single elliptical centric acquisitions in a reasonable scan time. MATERIALS AND METHODS: A time series of images with moderate spatial resolution was acquired using the 3D Time-Resolved Imaging of Contrast KineticS (3D TRICKS) technique with elliptical centric encoding during contrast arrival. Following venous opacification, a complete large centrically encoded k-space volume was acquired. The high-spatial-frequency portions of this volume were combined with a 3D TRICKS time frame to form a high-resolution image. An additional single image is formed by suppressing background and signal averaging all acquired data, including post-venous low-spatial-frequency data. For this image, 2D temporal correlation analysis is used to suppress low-spatial-frequency vein contributions. Arrival time and spatial correlations are used to suppress background. RESULTS: The 3D TRICKS time frame may be selected to ensure a combined high-resolution image that has optimal central k-space sampling for any vascular region. The single image formed by signal averaging all acquired data has increased contrast-to-noise (CNR) and signal-to-noise (SNR) ratios. CONCLUSION: The advantages of time-resolved and high-spatial-resolution imaging were combined using an extended dual-phase acquisition. Some SNR and CNR gain was achieved by signal averaging. This process is facilitated by background and vein suppression.

Animals↗

CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current.

With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT10, CT40, CT80 and CT120) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET(CT10)-PET(CT120). In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET(CT10)-PET(CT120). In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68Ge sources were employed for the attenuation correction of the FDG emission scan (PET(CT80), PET(68Ge)). Uptake values and lesion size in 26 lesions were compared on PET(CT80) and PET(68Ge). In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET(CT80) and PET(68Ge). In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68Ge attenuation correction are compared.

Adolescent↗

Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants.

Germanium-68 based attenuation correction (PET(Ge68)) is performed in positron emission tomography (PET) imaging for quantitative measurements. With the recent introduction of combined in-line PET/CT scanners, CT data can be used for attenuation correction. Since dental implants can cause artefacts in CT images, CT-based attenuation correction (PET(CT)) may induce artefacts in PET images. The purpose of this study was to evaluate the influence of dental metallic artwork on the quality of PET images by comparing non-corrected images and images attenuation corrected by PET(Ge68) and PET(CT). Imaging was performed on a novel in-line PET/CT system using a 40-mAs scan for PET(CT) in 41 consecutive patients with high suspicion of malignant or inflammatory disease. In 17 patients, additional PET(Ge68) images were acquired in the same imaging session. Visual analysis of fluorine-18 fluorodeoxyglucose (FDG) distribution in several regions of the head and neck was scored on a 4-point scale in comparison with normal grey matter of the brain in the corresponding PET images. In addition, artefacts adjacent to dental metallic artwork were evaluated. A significant difference in image quality scoring was found only for the lips and the tip of the nose, which appeared darker on non-corrected than on corrected PET images. In 33 patients, artefacts were seen on CT, and in 28 of these patients, artefacts were also seen on PET imaging. In eight patients without implants, artefacts were seen neither on CT nor on PET images. Direct comparison of PET(Ge68) and PET(CT) images showed a different appearance of artefacts in 3 of 17 patients. Malignant lesions were equally well visible using both transmission correction methods. Dental implants, non-removable bridgework etc. can cause artefacts in attenuation-corrected images using either a conventional 68Ge transmission source or the CT scan obtained with a combined PET/CT camera. We recommend that the non-attenuation-corrected PET images also be evaluated in patients undergoing PET of the head and neck.

Adolescent↗

Absolute quantification of cerebral blood flow with magnetic resonance, reproducibility of the method, and comparison with H2(15)O positron emission tomography.

While H2(15)O positron emission tomography (PET) is still the gold standard in the quantitative assessment of cerebral perfusion (rCBF), its technical challenge, limited availability, and radiation exposure are disadvantages of the method. Recent work demonstrated the feasibility of magnetic resonance (MR) for quantitative cerebral perfusion imaging. There remain open questions, however, especially regarding reproducibility. The main purpose of this study was to assess the accuracy and reproducibility of MR-derived flow values to those derived from H2(15)O PET. Positron emission tomography and MR perfusion imaging was performed in 20 healthy male volunteers, who were chronic smokers, on day 1 and day 3 of a 4-day hospitalization. Subjects were randomly assigned to one of two groups, each with 10 subjects. One group was allowed to smoke as usual during the hospitalization, while the other group stopped smoking from day 2. Positron emission tomography and MR images were coregistered and rCBF was determined in two regions of interest, defined over gray matter (gm) and white matter (wm), yielding rCBF(PET)gm, rCBF(MR)gm, rCBF(PET)wm, and rCBF(MR)wm. Bland-Altman analysis was used to investigate reproducibility by assessing the difference rCBFday3 - rCBFday1 in eight continual-smoker volunteers. The analysis showed a good reproducibility for PET, but not for MR. Mean +/- SD of the difference rCBFday3 - rCBFday1 in gray matter was 6.35 +/- 21.06 and 0.49 +/- 5.27 mL x min(-1) x 100 g(-1) for MR and PET, respectively; the corresponding values in white matter were 2.60 +/- 15.64 and -1.14 +/- 4.16 mL x min(-1) x 100 g(-1). The Bland-Altman analysis was also used to assess MRI and PET agreement comparing rCBF measured on day 1. The analysis demonstrated a reasonably good agreement of MR and PET in white matter (rCBF(PET)wm - rCBF(MR)wm; -0.09 +/- 7.23 mL x min(-1) x 100 g(-1)), while in gray matter a reasonable agreement was only achieved after removing vascular artifacts in the MR perfusion maps (rCBF(PET)gm - rCBF(MR)gm; -11.73 +/- 14.52 mL x min(-1) x 100 g(-1)). In line with prior work, these results demonstrate that reproducibility was overall considerably better for PET than for MR. Until reproducibility is improved and vascular artifacts are efficiently removed, MR is not suitable for reliable quantitative perfusion measurements.

Adult↗

PET diagnostic accuracy: improvement with in-line PET-CT system: initial results.

The authors describe the initial application for tumor staging with an in-line system with a positron emission tomographic (PET) scanner and a multi-detector row helical computed tomographic (CT) scanner combined in one machine. Fifty-three patients underwent imaging with four CT tube currents and PET emission and transmission data acquisition. Stepwise analysis of coregistered images revealed a significant (P <.05, McNemar test) improvement in lesion classification between PET images alone and coregistered images from the PET-CT examination.

Abdominal Neoplasms↗

Application of oral contrast media in coregistered positron emission tomography-CT.

OBJECTIVE: Coregistration of positron emission tomography (PET) and CT images results in significantly improved localization of abnormal FDG uptake compared with PET images alone. For delineation of intestinal structures, application of oral contrast media is a standard procedure in CT. The influence of oral contrast agents in PET imaging using CT data for attenuation correction was evaluated in a comparative study on an in-line PET-CT system. SUBJECTS AND METHODS: Sixty patients referred for PET-CT were evaluated in two groups. One group of 30 patients received oral Gastrografin 45 min before data acquisition. The second group received no contrast medium. PET images were reconstructed, using CT data for attenuation correction. Image analysis was performed by two reviewers in consensus, using a 4-point scale comparing FDG-uptake in the gastrointestinal tract in PET images of both groups. Furthermore, correlation of FDG uptake and localization of contrast media in the intestinal tract in CT images were determined. RESULTS: No significant difference in FDG uptake in PET images in all regions of the gastrointestinal tract except the ascending colon was seen in both groups. No correlation was found in the location of increased FDG uptake and contrast media in the CT images. CONCLUSION: An oral contrast agent can be used for coregistered PET-CT without the introduction of artifacts in PET.

Administration, Oral↗

Accuracy of image coregistration of pulmonary lesions in patients with non-small cell lung cancer using an integrated PET/CT system.

UNLABELLED: The purpose of this study was to evaluate the accuracy of image coregistration of PET and CT (PET/CT) images in patients with lung lesions and the influence of the breathing protocol during CT. METHODS: Seventy-five patients with a solitary and well-circumscribed pulmonary lesion (non-small cell lung cancer; size, 10-30 mm) underwent PET/CT on a combined scanner. CT was acquired during shallow breathing in 37 patients and during normal expiration (i.e., the level reached when the patient exhaled without forcing expiration and then held the breath) in 38 patients. The volume of interest of each lesion was defined separately on PET and CT images, and the geometric center of gravity (COG) was assessed. The distance of COGs between the PET image and the CT image was measured. All lesions were classified according to 4 lung regions: apical, peripheral, central, and lung base. The mismatch between COG(PET) and COG(CT) was compared between regions and patient groups using a 2-way ANOVA with the Bonferroni-Dunn test for post hoc comparisons. RESULTS: The range of COG distance between PET and CT was 1.7-5.4 mm in the apex, 0.5-14.7 mm in the periphery, 0.7-5.9 mm centrally, and 2.9-11.3 mm in the lung base. The match between PET and CT was significantly better in patients who had the CT scan obtained during normal expiration than in patients who performed shallow breathing during CT scanning (P = 0.024). No reciprocal effects were found (interaction P = 0.76). The mismatch of lesions depends significantly on lung region (P < 0.0001). Post hoc analysis showed a significant difference between the upper 2 regions and the lower 2 regions (all P < or = 0.002) but not between the apex and the central region (P = 0.95) and between the peripheral region and the lung base (P = 0.15). The lesion size had no influence on the COG mismatch. CONCLUSION: The match of lung lesions in coregistered PET/CT images is better when acquiring the CT scan during normal expiration. The coregistration accuracy is better in the upper and central parts of the lung. The normal expiration protocol is suggested to be superior to shallow breathing during CT scanning.

Adolescent↗