PubMed Health⌕ Search

Biomedical subjects

Thomas Frauenfelder

Publications and source records attributed to Thomas Frauenfelder.

7 recordsLinked to original sources

In-vivo flow simulation in coronary arteries based on computed tomography datasets: feasibility and initial results.

The purpose of this paper was to non-invasively assess hemodynamic parameters such as mass flow, wall shear stress (WSS), and wall pressure with computational fluid dynamics (CFD) in coronary arteries using patient-specific data from computed tomography (CT) angiography. Five patients (two without atherosclerosis, three with atherosclerosis) underwent retrospectively electrocardiogram (ECG) gated 16-detector row CT using ECG-pulsing and geometric models of coronary arteries were reconstructed for CFD analysis. Blood flow was considered laminar, incompressible, Newtonian, and pulsatile. The mass flow, WSS, and wall pressure were quantified and flow patterns were visualized. The wall pressure continuously decreased towards distal segments and showed pressure drops in stenotic segments. In coronary segments without atherosclerotic wall changes, WSS remained low, even during phases of high flow velocity, whereas in atherosclerotic vessels, the WSS was elevated already at low flow velocities. Stenoses and post-stenotic dilatations led to flow acceleration and rapid deceleration, respectively, including a distortion of flow. Areas of high WSS and high flow velocities were found adjacent to plaques, with values correlating with the degree of stenosis. CFD provided detailed mass flow measurements. CFD analysis is feasible in normal and atherosclerotic coronary arteries and provides the rationale for further investigation of the links between hemodynamic parameters and the significance of coronary stenoses.

Aged↗

Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control.

The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1+/-11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14+/-9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter > or =1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3+/-3.9 kg/m2 (range 22.4-36.3 kg/m2), mean heart rate during CT was 70.3+/-14.2 bpm (range 47-102 bpm), and mean Agatston score was 821+/-904 (range 0-3,110). Image quality was diagnostic (scores 1-3) in 98.6% (414/420) of segments (mean image quality score 1.68+/-0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control.

Adult↗

Thick maximum intensity projections for the assessment of left ventricular function with 64-slice computed tomography.

OBJECTIVE: The objective of this study was to assess the accuracy of thick maximum intensity projections (MIP) from computed tomography (CT) data sets mimicking projection images from biplane ventriculography for evaluation of left ventricular (LV) parameters. MATERIALS AND METHODS: Fifty-eight patients underwent 64-slice CT. Multiphase images were reconstructed in 10% steps of the RR interval. MIP images (70-mm thickness) of the contrast-enhanced LV in fixed 30 degrees right anterior oblique (RAO)/60 degrees left anterior oblique (LAO) and in adapted short-/long-axis planes were reconstructed. LV parameters were calculated using the area-length method formula. Three-dimensional assessment with semiautomated software served as reference standard. RESULTS: Use of thick MIP reconstructions had a high intermethod reliability (86-94%) compared with the 3-dimensional approach. Smaller measurement errors were found for thick MIP reconstructions in adapted short-/long-axis planes. A significant projection error (3.0%, P < 0.001) of thick MIP reconstructions was found using fixed 30 degrees RAO/60 degrees LAO compared with adapted short-/long-axis reconstructions. CONCLUSION: Thick MIP reconstructions with adapted short-/long-axis planes allow an accurate assessment of LV parameters compared with the established 3-dimensional method.

Adult↗

Computational simulation of intracoronary flow based on real coronary geometry.

OBJECTIVE: To assess the feasibility of computationally simulating intracoronary blood flow based on real coronary artery geometry and to graphically depict various mechanical characteristics of this flow. METHODS: Explanted fresh pig hearts were fixed using a continuous perfusion of 4% formaldehyde at physiological pressures. Omnipaque dye added to lead rubber solution was titrated to an optimum proportion of 1:25, to cast the coronary arterial tree. The heart was stabilized in a phantom model so as to suspend the base and the apex without causing external deformation. High resolution computerized tomography scans of this model were utilized to reconstruct the three-dimensional coronary artery geometry, which in turn was used to generate several volumetric tetrahedral meshes of sufficient density needed for numerical accuracy. The transient equations of momentum and mass conservation were numerically solved by employing methods of computational fluid dynamics under realistic pulsatile inflow boundary conditions. RESULTS: The simulations have yielded graphic distributions of intracoronary flow stream lines, static pressure drop, wall shear stress, bifurcation mass flow ratios and velocity profiles. The variability of these quantities within the cardiac cycle has been investigated at a temporal resolution of 1/100th of a second and a spatial resolution of about 10 microm. The areas of amplified variations in wall shear stress, mostly evident in the neighborhoods of arterial branching, seem to correlate well with clinically observed increased atherogenesis. The intracoronary flow lines showed stasis and extreme vorticity during the phase of minimum coronary flow in contrast to streamlined undisturbed flow during the phase of maximum flow. CONCLUSIONS: Computational tools of this kind along with a state-of-the-art multislice computerized tomography or magnetic resonance-based non-invasive coronary imaging, could enable realistic, repetitive, non-invasive and multidimensional quantifications of the effects of stenosis on distal hemodynamics, and thus help in precise surgical/interventional planning. It could also add insights into coronary and bypass graft atherogenesis.

Animals↗

Collision handling of deformable anatomical models for real-time surgery simulation.

Efficient collision handling of dynamically deforming anatomical models is a very challenging problem in real-time surgery simulation. In this paper, we present a new, efficient approach that detects collisions and self-collisions of deformable models. Our algorithm is integrated in a simulation framework for multiple interacting objects. This framework consists of three components. The first one computes the dynamic behavior of deformable structures using an efficient and robust approach with distance- and volume-preserving constraints. The second component detects collisions and self-collisions of deformable models. A novel image-space technique is employed that detects volumetric intersections. This allows to compute the penetration depth which is used to resolve collisions in the third component of our framework. Our system handles volumetric deformable models of up to several thousand surface triangles and tetrahedra in real-time and can be used in surgical training systems.

Algorithms↗

Computational fluid dynamics: hemodynamic changes in abdominal aortic aneurysm after stent-graft implantation.

The aim of this study was to demonstrate quantitatively and qualitatively the hemodynamic changes in abdominal aortic aneurysms (AAA) after stent-graft placement based on multidetector CT angiography (MDCT-A) datasets using the possibilities of computational fluid dynamics (CFD). Eleven patients with AAA and one patient with left-side common iliac aneurysm undergoing MDCT-A before and after stent-graft implantation were included. Based on the CT datasets, three-dimensional grid-based models of AAA were built. The minimal size of tetrahedrons was determined for grid-independence simulation. The CFD program was validated by comparing the calculated flow with an experimentally generated flow in an identical, anatomically correct silicon model of an AAA. Based on the results, pulsatile flow was simulated. A laminar, incompressible flow-based inlet condition, zero traction-force outlet boundary, and a no-slip wall boundary condition was applied. The measured flow volume and visualized flow pattern, wall pressure, and wall shear stress before and after stent-graft implantation were compared. The experimentally and numerically generated streamlines are highly congruent. After stenting, the simulation shows a reduction of wall pressure and wall shear stress and a more equal flow through both external iliac arteries after stenting. The postimplantation flow pattern is characterized by a reduction of turbulences. New areas of high pressure and shear stress appear at the stent bifurcation and docking area. CFD is a versatile and noninvasive tool to demonstrate changes of flow rate and flow pattern caused by stent-graft implantation. The desired effect and possible complications of a stent-graft implantation can be visualized. CFD is a highly promising technique and improves our understanding of the local structural and fluid dynamic conditions for abdominal aortic stent placement.

Aortic Aneurysm, Abdominal↗

Nontraumatic emergent abdominal vascular conditions: advantages of multi-detector row CT and three-dimensional imaging.

In the past decade, great strides have been made in the development of helical computed tomography (CT) that have led to shorter scanning time and higher spatial resolution. A wide range of traumatic and nontraumatic emergent conditions may be quickly and accurately diagnosed with multi-detector row CT. Multi-detector row CT angiography is the preferred method for imaging in emergent abdominal vascular conditions because it enables the acquisition of high-spatial-resolution volumetric image data during a single breath hold. Unlike catheter angiography, multi-detector row CT angiography not only depicts the vessels but also allows assessment of perfusion in adjacent organs. To make the most effective diagnostic use of multi-detector row CT angiography and three-dimensional image postprocessing, radiologists must be familiar with the optimal CT angiographic protocols and with the typical CT findings in various emergent vascular conditions. This article describes the protocols used in 11 patients with conditions including ruptured abdominal aortic aneurysm, secondary aortoduodenal fistula, splanchnic segmental arterial mediolysis, and Wegener-type vasculitis with visceral involvement. All of the diagnoses in these 11 cases were made in the emergency department, and the delay between imaging and diagnosis was decreased considerably by avoiding the transfer of patients for catheter angiography.

Abdomen, Acute↗