Standards and measurements for assessing bone health-workshop report co-sponsored by the International Society for Clinical Densitometry (ISCD) and the National Institute of Standards and Technology (NIST).

This article reports and discusses the results of the recent ISCD-NIST Workshop on Standards and Measurements for Assessing Bone Health. The purpose of the workshop was to assess the status of efforts to standardize and compare results from dual-energy X-ray absorptiometry (DXA) scans, and then to identify and prioritize ongoing measurement and standards needs.

Absorptiometry, Photon↗

Cross-calibration and minimum precision standards for dual-energy X-ray absorptiometry: the 2005 ISCD Official Positions.

The International Society for Clinical Densitometry (ISCD) Committee on Standards of Bone Measurement (CSBM) consists of experts in technical aspects of bone densitometry. The CSBM recently reviewed the scientific literature on cross-calibration and precision assessment. A report with recommendations was presented at the 2005 ISCD Position Development Conference (PDC). Based on a thorough review of the data by the ISCD Expert Panel during the conference, the ISCD adopted Official Positions with respect to (1) cross-calibration when changing or replacing hardware; (2) the approach to cross-calibration when an entire system is changed to one made by either the same or a different manufacturer; (3) when no cross-calibration study or bone mineral density (BMD) comparison is done between facilities; and (4) the minimum acceptable precision for an individual technologist. We present here the ISCD Official Positions on these topics that were established as a result of the 2005 PDC, together with the associated rationales and supportive evidence.

Absorptiometry, Photon↗

QDR 4500A dual-energy X-ray absorptiometer underestimates fat mass in comparison with criterion methods in adults.

BACKGROUND: Dual-energy X-ray absorptiometry (DXA) has become one of the most frequently used methods for estimating human body composition. Although the DXA technique has been validated for the measurement of fat-free mass and fat mass, differences in calibration between instruments produced by different manufacturers, as well as between different models produced by the same manufacturer, have been reported. OBJECTIVE: The objective was to compare the calibration of the QDR 4500A against criterion methods in a large heterogeneous population. DESIGN: DXA-derived body-composition data were obtained from 7 studies: 6 data sets were provided by the investigators, one of which was published. The data included fat mass and fat-free mass measured with a QDR 4500A and criteria measurements of body composition from total body water by dilution at 4 centers, densitometry from 1 center, and four-compartment analysis at 2 centers. RESULTS: In the cohort of 1195 subjects, 602 men and 593 women aged 19-82 y with a body mass index (in kg/m2) of 16-44, the fan-beam DXA overestimated fat-free mass (P < 0.05). A significant difference was observed in all 7 data sets, and the mean (+/-SE) was 5 +/- 1%. CONCLUSIONS: It is recommended that the lean soft tissue mass estimate with the fan-beam QDR 4500A be reduced by 5% and that for fat mass be increased by that same mass. This finding is particularly important because the National Health and Nutrition Examination Survey is using the QDR 4500A to assess body composition in a nationally representative sample of persons in the United States.

Absorptiometry, Photon↗

Treatment with raloxifene for 2 years increases vertebral bone mineral density as measured by volumetric quantitative computed tomography.

Volumetric quantitative computed tomography (vQCT), using multiple thin-slice acquisition, measures three-dimensional volumetric bone mineral density (BMD, mg/cm3). vQCT is often used to measure BMD of lumbar vertebrae and may detect early changes in trabecular, cortical, or integral BMD that extend beyond the technical limits of areal dual X-ray absorptiometry (DXA) BMD measurements. The objective of this study was to determine the effect of 2 years of raloxifene (RLX) treatment on several volumetric BMD measures in a subset of postmenopausal women (n=58) enrolled in the Multiple Outcomes of Raloxifene Evaluation (MORE) trial. Patients in this study were randomized to one of three treatment groups: placebo (n=21), RLX 60 mg/day (n=17), or RLX 120 mg/day (n=20), and all patients received daily calcium (500 mg) and vitamin D (400-600 IU) supplementation. Data from the raloxifene treatment groups were pooled for each analysis. Following 2 years of raloxifene treatment, there was a significant percent change from baseline in the vQCT regions of interest (ROIs) of midintegral BMD, total trabecular BMD, and total integral BMD (P<0.05) compared to placebo, while there was no significant change in the spinal DXA BMD measurement. These data provide the first longitudinal assessment by vQCT of changes in vertebral bone density after 2 years of treatment with raloxifene. vQCT appears to be a valuable technique for measuring the effects of raloxifene treatment in this population of postmenopausal women with osteoporosis.

Absorptiometry, Photon↗

Effect of raloxifene on the risk of new vertebral fracture in postmenopausal women with osteopenia or osteoporosis: a reanalysis of the Multiple Outcomes of Raloxifene Evaluation trial.

Raloxifene reduces vertebral fracture risk in postmenopausal women with osteoporosis and established osteoporosis, but its efficacy in women with osteopenia has not been studied. The objective of this study was to evaluate the effect of raloxifene hydrochloride on the risk of vertebral fractures in postmenopausal women with osteopenia and to compare this effect with that in women with osteoporosis as defined by the bone mineral density (BMD) T-score at the hip. We studied the 3204 postmenopausal women with osteopenia or osteoporosis without vertebral fractures at baseline in the Multiple Outcomes of Raloxifene Evaluation trial. Compared with placebo, 60 mg/day raloxifene reduced the risk of new vertebral fractures at 3 years independent of baseline total hip BMD. The relative risk for new vertebral fractures for the raloxifene group compared with placebo was 0.53 (95% CI, 0.32-0.88) for those with osteopenia and 0.31 (0.06-0.71) for those with osteoporosis. In raloxifene-treated women the rate of vertebral fracture was similar in women with osteoporosis (2%) to that in women with osteopenia (1.9%). For clinically apparent vertebral fractures, the relative risk of fracture in the osteopenia group for raloxifene was 0.25 (0.04-0.63) compared with placebo. There were no new clinical vertebral fractures in women with osteoporosis receiving raloxifene, whereas four occurred in the placebo group. We conclude that treatment with 60 mg/day raloxifene significantly decreases the risk of new vertebral fractures and new clinical vertebral fractures in postmenopausal women without baseline vertebral fracture who have osteopenia or osteoporosis.

Aged↗

Comparison of the effectiveness of 2 dual-energy X-ray absorptiometers with that of total body water and computed tomography in assessing changes in body composition during weight change.

BACKGROUND: Little information is available on the assessment of changes in body composition as a function of weight change with the use of the fan beam of dual-energy X-ray absorptiometry (DXA). OBJECTIVE: The objective was to determine the accuracy of the fan beam of the QDR 4500A densitometer and the pencil beam of the QDR 2000 densitometer in estimating changes in whole-body lean soft tissue mass (LSTM(DXA)) and fat mass (FM) with weight change. DESIGN: Thirty-seven subjects who lost 5.7 +/- 4.5 kg were measured before and after weight change. Using total body water and computed tomography (CT) of the midthigh, we compared changes in FFM(TBW) and LSTM(CT) with changes in LSTM(DXA). RESULTS: Overall, compared with TBW, the fan beam gave a larger estimate of change (macro x +/- SD) in LSTM (fan beam - TBW: -0.7 +/- 1.6 kg) than did the pencil beam (pencil beam - TBW: -0.1 +/- 1.6 kg). When the change in LSTM obtained with the fan beam and pencil beam was regressed against the change in FFM(TBW), the slope of the line for the fan beam was 0.97 (r(2) = 0.61) and that for the pencil beam was 0.86 (r(2) = 0.61). Regression analysis showed that the results between the 2 units were not interchangeable. For the midthigh region, the change in LSTM(CT) was moderately correlated with the change in LSTM(DXA) with the fan beam and pencil beam. CONCLUSIONS: The measurement of change in LSTM with the fan and pencil beams provides the same relation to changes in FFM assessed by TBW, but the 2 systems are not interchangeable.

Absorptiometry, Photon↗

QDR 4500A DXA overestimates fat-free mass compared with criterion methods.

This study evaluated the accuracy with which the dual-energy X-ray absorptiometer (Hologic QDR 4500A) measured fat-free mass (FFM), fat mass (FM), and hydration of FFM. In a study of 58 men and women (ages 70-79 yr), the QDR 4500A was found to provide a systematically higher estimate of FFM and lower estimate of FM than a four-component model of body composition. A correction factor from this study was developed and applied to two other samples (n = 13 and 37). We found mean corrected levels of FFM and FM to be equivalent to that obtained by the four-component model or total body water. In addition, the hydration of the corrected FFM was closer to the established hydration level in adult samples and that obtained from the four-component model. These findings suggest that the current calibration of the fan-beam system of the Hologic QDR 4500A provides an overestimate of FFM and underestimate of FM compared with reference methods.

Absorptiometry, Photon↗