PubMed Health⌕ Search

Biomedical subjects

Thomas H Mourey

Publications and source records attributed to Thomas H Mourey.

3 recordsLinked to original sources

Importance of solubility in the sample preparation of poly(ethylene terephthalate) for MALDI TOFMS.

The role of solubility in the sample preparation process for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is demonstrated for oligomeric and medium molar mass poly(ethylene terephthalate) (PET). For low molar mass oligomers (PET-1), minor discrimination effects were observed when the sample was not completely in solution. MALDI spectra of medium molar mass PET, representative of the entire molar mass distribution, were obtained only when a good solvent for PET was used, such as 1,1,1,3,3,3-hexafluoro-2-propanol (commonly referred to as HFIP), as the sample preparation solvent and dithranol as the matrix. The azeotropic composition of 70:30 CH(2)Cl(2)/HFIP better solubilizes the more nonpolar matrixes, which enables more latitude in selecting sample preparation conditions than pure HFIP. Segregation effects were observed when the azeotrope mixture was diluted with tetrahydrofuran, resulting in large molar mass distribution discrimination effects in the MALDI spectra. Dilution with CH(2)Cl(2) resulted in a significant decrease in the overall signal intensity for the entire polymer distribution. With each attempt to dilute the azeotrope, the sample after solvent evaporation was visibly heterogeneous, which resulted in shot-to-shot variability. Both examples demonstrate the importance of constant solvent composition during solvent evaporation. The compatibility of matrix and polymer was explored using relative HPLC retention times. Consistent with previous work in our laboratories, it was found that the matrix/polymer combination that has the closest match of retention time resulted in the best MALDI signal intensity.

Image Enhancement↗

Polymerizable bis(2-ethylhexyl)sulfosuccinate: application in microemulsion polymerization.

A hygroscopic and polymerizable salt ([2-methacryloyloxy]ethyl trimethylammonium chloride) is used to ion exchange the sodium ion in AOT (bis[2-ethylhexyl]sulfosuccinate, sodium salt) to produce a polymerizable form of AOT, MDOS ([2-methacryloyloxy]ethyl trimethylammonium bis[2-ethylhexyl]sulfosuccinate). A partial ternary phase diagram of water, MDOS, and methyl methacrylate (MMA) was determined at room temperature (22 +/- 1 degrees C). A relatively large L2 domain is obtained, but this domain is smaller than that obtained with AOT. Microemulsion polymerization in this domain at 70 degrees C, using AIBN (azoisobutyronitrile) as an initiator, produces an optically clear copolymer solid domain nearly as large as the L2 domain. This interesting behavior contrasts with similar studies of Pavel and Mackay [Langmuir 2000, 16, 8528] using a polymerizable surfactant DDAMA (didecyldimethylammonium methacrylate) that produced a much larger L2 domain than MDOS but yielded a much smaller optically clear domain after thermally initiated polymerization. Thermogravimetric analysis indicates that optically clear composites obtained at an MDOS/MMA weight ratio of 1:4 and containing 5% water (w/w; weight % water in microemulsion) released the water in a transition commencing around 160 degrees C and continuing to 250 degrees C. Thereafter, the thermal decomposition was substantially impeded relative to poly(methyl methacrylate) as a control, which was due to the fire-resistant nature of the MDOS monomer. Molecular weight measurements indicate MDOS/MMA copolymers form substantially higher molecular weights as the proportion of MDOS increases. At a given radius of gyration, higher MDOS-containing copolymers exhibit higher molecular weights, suggesting a more compact structure with increasing MDOS.

Journal Article↗

Size-exclusion chromatography in 1,1,1,3,3,3-hexafluoro-2-propanol.

1,1,1,3,3,3-Hexafluoroisopropanol is re-examined as an eluent for size-exclusion chromatography (SEC) of polyesters, nylons, and other polar polymers. It is shown that anomalous SEC behavior reported in previous literature can be eliminated by adding 0.01 M tetraethylammonium nitrate to the eluent. The eluent modifier does not affect the solution viscosity or root-mean-square radii of moderately polar polymers such as polyesters and nylons, but it does decrease these quantities for more polar polymers such as poly(ethylene oxide) and poly(2-vinylpyridine). More important, this salt appears to minimize repulsive interactions with styrene-divinylbenzene column packings that have contributed to non-ideal size-exclusion behavior. As a result, conditions are established that satisfy universal calibration.

Calibration↗