PubMed Health⌕ Search

Biomedical subjects

Thomas J Masaryk

Publications and source records attributed to Thomas J Masaryk.

At least 19 recordsLinked to original sources

Stent-assisted detachable coil embolization of pseudoaneurysms in the coronary circulation.

Pseudoaneurysms in the coronary circulation are an uncommon occurrence that can develop spontaneously in the setting of atherosclerosis or can develop after catheter-based coronary interventions. The natural history, clinical outcome, and optimal therapy for pseudoaneurysms in the coronary circulation are not clearly established. Recent advances in the techniques and technologies used for endovascular treatment of intracranial aneurysms may be applicable to the management of coronary aneurysms and pseudoaneurysms. We present a case of spontaneous coronary pseudoaneurysm formation after paclitaxel drug-eluting stent implantation and a case of pseudoaneurysm formation in a saphenous vein graft that were both successfully treated with stent-assisted detachable coil embolization.

Aged↗

Neuroform in-stent stenosis: incidence, natural history, and treatment strategies.

OBJECTIVE: Delayed in-stent stenosis is an important and well-characterized complication of angioplasty and stenting for the treatment of intra- and extracranial atheromatous disease. The current series describes the incidence and natural history of in-stent stenosis after the deployment of the Neuroform stent within the cerebrovasculature for the treatment of aneurysms. METHODS: The collaborative Cleveland Clinic Foundation-Barrow Neurological Institute endovascular database was reviewed to identify cases of delayed moderate or severe in-stent stenosis observed during the follow-up of cerebral aneurysms treated with the Neuroform stent. The hospital charts, clinic records, and operative reports for these patients were reviewed. RESULTS: Of a total of 156 patients with follow-up, nine (5.8%) cases of moderate or severe delayed (>2 mo) in-stent stenosis were identified, including two parent vessel occlusions. In two cases, patients presented 3 months after stent-supported aneurysm embolization with focal neurological symptoms. Both of these patients were treated with angioplasty. One eventually required surgical bypass. Of the seven asymptomatic patients, four demonstrated some degree of spontaneous resolution at follow-up, one progressed to complete occlusion, one is awaiting further follow-up, and one patient died of unrelated causes. Of the nine patients in the series, five were treated with "bioactive" coils (Matrix, Hydrocoil, Cerecyte), three were treated with bare platinum coils, and one was treated with stenting alone. The earliest time interval to diagnosis was 2.5 months and 3 months for asymptomatic and symptomatic patients, respectively. The earliest interval documented for spontaneous resolution was 9 months. CONCLUSION: Delayed Neuroform in-stent stenosis, occurring in 5.8% of cases, is not a rare phenomenon. The stenosis can be symptomatic and may require endovascular treatment or surgical bypass. In asymptomatic patients, a strategy of "watchful waiting" may be effective because many patients demonstrate partial or complete resolution at follow-up. The spontaneous resolution of delayed in-stent stenosis has not been previously described. This may be a phenomenon unique to the application of low radial force, self-expanding stents within the nonatheromatous cerebrovasculature.

Adult↗

Endovascular reconstruction with the Neuroform stent as monotherapy for the treatment of uncoilable intradural pseudoaneurysms.

OBJECTIVE: Intradural pseudoaneurysms have a malignant natural history and can be difficult to treat if parent vessel deconstruction is not feasible. These lesions often involve a long arterial segment and lack a defined saccular component that would safely accommodate the introduction of embolization coils. The current report describes the successful endovascular treatment of these lesions using a strategy of Neuroform stent reconstruction. METHODS: A retrospective review of the prospectively maintained Neuroform databases from our two institutions identified all intracranial aneurysms treated with the Neuroform stent alone, without embolization coils. The clinical charts, procedural data, and angiographic results were reviewed. RESULTS: Over a 38-month study period (10/02-2/06), 266 aneurysms were treated with the Neuroform stent. Of these, 10 were small "uncoilable" intradural pseudoaneurysms associated with subarachnoid hemorrhage. These lesions were treated using a strategy of endovascular stent reconstruction of the diseased vascular segment with one or more Neuroform stents (without concomitant coil embolization). Seven pseudoaneurysms were treated in the context of acute or subacute subarachnoid hemorrhage, and three were associated with a remote history of subarachnoid hemorrhage. Periprocedural complications occurred in two patients (clinically silent, intraprocedural thromboembolic event successfully treated with intra-arterial abciximab, symptomatic postprocedural stent thrombosis with successful thrombolysis, and excellent neurological recovery). Both complications occurred in patients with ruptured aneurysms and could be attributed to inadequate platelet inhibition at the time of the initial procedure. Follow-up conventional angiographic examinations were available for all 10 patients with pseudoaneurysms (1-18.5 mo; average, 9.0 mo). In nine cases, the aneurysms improved at follow-up, with either complete (n = 5) or near complete (n = 4) resolution. In one case, short-term follow-up (1 mo) demonstrated no significant change. No patient has rehemorrhaged after treatment. CONCLUSION: Endovascular Neuroform stent reconstruction represents an optimal strategy for the management of intradural pseudoaneurysms that require a constructive treatment strategy and are too small to accommodate the introduction of embolization coils. Nine out of 10 patients in the current series treated with this strategy demonstrated some degree of endovascular remodeling with either complete (n = 5) or partial (n = 4) angiographic resolution at follow-up. No rehemorrhages were encountered. Adequate antiplatelet therapy, even in the setting of acute subarachnoid hemorrhage, is prerequisite for the avoidance of thromboembolic complications.

Adolescent↗

Neurovascular rescue.

Neurovascular complications of carotid artery stenting (CAS) include intracranial embolism and hemorrhage, carotid dissection, in-stent thrombosis and vasospasm. Management of these crises requires knowledge of the intracranial vascular anatomy and collateral circulation, correct identification of the complication and its clinical implications, and a response plan that is appropriate to the complication and to the skill set of the operator. In this chapter the authors discuss techniques for the avoidance and management of CAS procedural complications.

Angioplasty↗

Balloon-in-stent technique for the constructive endovascular treatment of "ultra-wide necked" circumferential aneurysms.

INTRODUCTION: Circumferential aneurysms, which incorporate >180 degrees of the circumference of the parent vessel, present a unique therapeutic challenge, particularly in circumstances in which a deconstructive treatment strategy is not feasible. We detail a novel technique for endovascular parent vessel reconstruction with aneurysm embolization. METHODS: We performed a retrospective review of the prospectively maintained databases of our two institutions to identify cases in which a balloon-in-stent technique had been used to treat circumferential aneurysms. During the first stage of this technique, a stent (Neuroform [Boston Scientific, Natick, MA], Multilink Vision [Guidant, Indianapolis, IN], or Bx Velocity [Cordis, New Brunswick, NJ]) is placed across the neck of the aneurysm to achieve parent vessel reconstruction. During the second stage, aneurysm coil embolization is performed with a compliant temporary occlusion balloon (Sentry [Boston Scientific, Natick, MA] or Hyperglide [Microtherapeutics, Irvine, CA]) placed within the stent to unambiguously demarcate and protect the parent vessel. In some cases, during the course of the embolization, coils project over and obscure the parent vessel in both working views. Before each coil detachment, the protection balloon is deflated under blank fluoroscopic roadmap visualization. The absence of shifting of any portion of the coil mass during balloon deflation indicates that the introduced coil is external to the stent-reconstructed parent vessel (i.e., within the aneurysm) and can be detached. This process is repeated until satisfactory aneurysm embolization is achieved. After embolization, the balloon catheter may be exchanged for a stent delivery system to facilitate the placement of a second stent. RESULTS: Seven patients underwent balloon-in-stent-assisted embolization over a 15-month period. Three were performed for internal carotid aneurysms, three for basilar trunk or basilar apex aneurysms, and one for a dissecting/fusiform V4 segment vertebral artery aneurysm. In three cases, the presence of the inflated balloon facilitated the manipulation of the image intensifier into a position which produced a "down-the-barrel" view of the parent vessel. In the four additional cases, for anatomic reasons, this view could not be achieved and coil mass projected over the reconstructed parent vessel in both views. Partial aneurysm occlusion (75-90%), was achieved in five cases, and near complete (>95%) occlusion was achieved in two cases. Complications included two significant retroperitoneal hematomas and two brainstem infarcts, both of which resulted in hemisensory symptoms. CONCLUSION: The balloon-in-stent technique provides a practical and safe treatment strategy for the management of circumferential aneurysms that are not amenable to deconstructive embolization.

Adult↗

Optical coherence tomography: a new method to assess aneurysm healing.

OBJECT: Aneurysmal subarachnoid hemorrhage affects approximately 10/100,000 people per year. Endovascular coil embolization is used increasingly to treat cerebral aneurysms and its safety and durability is rapidly developing. The long-term durability of coil embolization of cerebral aneurysms remains in question; patients treated using this modality require multiple follow-up angiography studies and occasional repeated treatments. METHODS: Optical coherence tomography (OCT) is an emerging imaging modality that uses backscattered light to produce high-resolution tomography of optically accessible biological tissues such as the eye, luminal surface of blood vessels, and gastrointestinal tract. Vascular OCT probes in the form of imaging microwires are presently available--although not Food and Drug Administration-approved--and may be adapted for use in the cerebral circulation. In this study the authors describe the initial use of OCT to make visible the neck of aneurysms created in a canine model and treated with coil embolization. Optical coherence tomography images demonstrate changes that correlate with the histological findings of healing at the aneurysm neck and thus may be capable of demonstrating human cerebral aneurysm healing. CONCLUSIONS: Optical coherence tomography may obviate the need for subsequent follow-up angiography studies as well as aid in the understanding of endovascular tissue healing. Data in this study demonstrate that further investigation of in vivo imaging with such probes is warranted.

Animals↗

Imaging in acute brain infarction.

Imaging in a patient suspected of having suffered an acute stroke is used primarily to clear the patient for thrombolytic therapy, by excluding intracranial hemorrhage and nonstroke causes of the patient's symptoms, within a critical 3-hour window. Noncontrast CT of the brain is the imaging test of choice for the initial evaluation of a patient with suspected acute ischemic stroke. It is rapid and readily available and has a high sensitivity for intracranial hemorrhage. Contrast-enhanced CT angiography and perfusion imaging may provide additional information with only a minimal increase in scanning time. Finally, diffusion-weighted magnetic resonance sequences have a high sensitivity for acute stroke and, with magnetic resonance perfusion imaging, may play an increasing role in the future treatment of stroke.

Aged↗

Stent-assisted angioplasty of intracranial vertebrobasilar atherosclerosis: midterm analysis of clinical and radiologic predictors of neurological morbidity and mortality.

BACKGROUND AND PURPOSE: Initial reports of stent-assisted angioplasty for intracranial vertebrobasilar atherosclerosis suggest this is a feasible treatment, but there have been little data regarding predictors of success or failure. We analyzed a series of patients for independent predictors of neurologic morbidity and mortality. METHODS: Patient charts and angiograms from 39 patients who underwent intracranial angioplasty and stent placement of vertebrobasilar stenoses were retrospectively reviewed to obtain clinical and detailed angiographic data on potential predictors of neurologic morbidity and mortality. Univariate analyses of these predictors were performed with either Fisher's exact test or simple logistic regression. Multivariate analysis was subsequently performed on the statistically significant predictors. RESULTS: Complete clinical data were obtained for 39 patients, and angiographic review was possible for 35 of them. Angiography revealed severe intracranial vertebral (n = 18), basilar (n = 15), or basilar and vertebral (n = 2) stenoses. Two patients (5.1%) died in the periprocedural period, nine patients (23.1%) had neurologic complications, and one patient (2.6%) had transient neurologic symptoms. Univariate analysis revealed female sex, diabetes, and failure of coumadin or heparin therapy were associated with neurologic morbidity, whereas female sex, Mori B lesion, and length-to-stenosis ratio were associated with mortality. The presence of diabetes was the only independent predictor of neurologic morbidity and mortality. CONCLUSION: Because of the limited number of patients available for analysis, the only independent predictor of neurologic morbidity and mortality was diabetes, but several other predictors showed trends that deserve further review in future series.

Angioplasty↗

Y-configured dual intracranial stent-assisted coil embolization for the treatment of wide-necked basilar tip aneurysms.

OBJECTIVE: Despite advances in both the surgical and endovascular treatment of intracranial aneurysms, wide-necked basilar tip aneurysms (i.e., basilar tip aneurysms in which both posterior cerebral arteries emanate from the base of a wide-necked aneurysm) represent a subset of aneurysms that continues to pose technical challenges in treatment. We sought to demonstrate the safety and short-term durability of a novel dual stent-assisted coil embolization technique. METHODS: Two Neuroform stents (Boston Scientific/Target, Fremont, CA) were deployed in the posterior cerebral arteries and the basilar artery, one passing through the interstices of the other in a Y-configuration, thereby recreating an aneurysm neck and enabling safe coil delivery while preserving the parent vessels. RESULTS: Seven patients with unruptured, asymptomatic, wide-necked basilar tip aneurysms involving both posterior cerebral arteries and ranging in size from 7 to 20 mm underwent treatment with this stent-assisted coiling technique. Two stents were successfully deployed in six of the patients and one stent was successfully deployed in the seventh. One patient developed a transient internuclear ophthalmoplegia, and another experienced transient partial right oculomotor nerve palsy. All aneurysms had complete or near-complete embolization with the initial procedure. Follow-up angiography performed 6 months (six patients) and 1 year (one patient) after treatment demonstrated coil compaction and slight recanalization in one patient and recanalization requiring retreatment in another. All patients were neurologically intact at least 6 months after the initial procedure, as well as subsequent procedures, without clinical signs of subarachnoid hemorrhage. CONCLUSION: These initial technical and clinical results are highly encouraging, and this technique may significantly improve the endovascular treatment of intracranial aneurysms.

Balloon Occlusion↗

Imaging of acute stroke: state of the art.

The high incidence of stroke, plus its fatal or debilitating outcome, has prompted tremendous advances over the last two decades on both diagnostic and therapeutic fronts. Multiple randomized trials have proven the utility of thrombolytic agents with rejuvenation of the role of diagnostic imaging. State of the art imaging (mainly computed tomography and magnetic resonance imaging) is crucial for patient selection (eg, excluding intracranial hemorrhage), diagnosis of stroke and prediction of prognosis. Here, we discuss the anatomic and physiologic changes due to an ischemic insult as manifested by modern imaging techniques, including diffusion and perfusion imaging, as well as demonstration of vascular disease by cross sectional angiography supplemented by three dimensional postprocessing. The main target of management is "Penumbra", or salvageable tissue, which is primarily dependent upon the expediency of the whole process, better expressed by the phrase "Time is Brain".

Angiography↗

Outcome after the treatment of spinal dural arteriovenous fistulae: a contemporary single-institution series and meta-analysis.

OBJECTIVE: Spinal dural arteriovenous fistulae (Type I spinal AVMs) are the most common type of spinal vascular malformations. The optimal treatment strategy has yet to be defined, and endovascular embolization is being offered with increasing frequency. A 7-year single-institution retrospective review of outcome with surgical management of Type I spinal AVMs is presented along with a meta-analysis of existing literature. METHODS: For the institutional analysis, a retrospective review of all patients who underwent treatment at our institution for Type I spinal AVMs was performed. Between 1995 and the present (the time frame during which endovascular treatments were available), 19 consecutive patients were treated. Follow-up was performed by clinical examination or telephone interview, and functional status was measured by use of the Aminoff-Logue score. For the meta-analysis, a MEDLINE search between 1966 and the present was performed for surgical, endovascular, or combined treatment of spinal dural arteriovenous fistula. These series were included in a meta-analysis to evaluate success and failure rates, complications, and functional outcome. Specifically, embolization and microsurgery were compared. RESULTS: For the institutional analysis, 18 of 19 patients were available for long-term follow-up after surgery. There were no surgical failures, but one complication was seen. Patients demonstrated a statistically significant improvement in gait and bladder function after surgery. For the meta-analysis, 98% of those patients treated with microsurgery had their dural arteriovenous fistulae successfully obliterated after the initial treatment, compared with only 46% with embolization, as judged by radiographic or clinical follow-up. 89% percent of patients demonstrated improvement or stabilization in neurological symptoms after surgical treatment. Few complications were demonstrated with either surgery or embolization. CONCLUSION: At this point, surgery seems to be superior to embolization for the management of spinal dural arteriovenous fistula. The fistula is usually obliterated after the initial treatment, with few clinical or radiographic recurrences. The majority of patients either improve or stabilize after treatment. Few worsen, and the morbidity is minimal. It is reasonable to attempt initial embolization, especially at the time of the initial diagnostic spinal angiogram. The treating physicians and patients should be aware of the high chance of recurrence, and patients may ultimately require surgery or repeat embolization. After endovascular therapy, patients are committed to repeat angiography and probably embolization. For these reasons, it is the authors' opinion that surgery should be used as the first-line therapy for spinal dural arteriovenous fistulae.

Adult↗

A transcranial approach for direct mechanical thrombectomy of dural sinus thrombosis. Report of two cases.

Cerebral venous sinus thrombosis is often difficult to manage. Treatment options include systemically delivered anticoagulation therapy or chemical thrombolysis. Targeted endovascular delivery of thrombolytic agents is currently a popular option, but it carries an increased risk of hemorrhage. These strategies require significant time to produce thrombolysis, often in a patient with a rapidly deteriorating neurological condition. Rapid mechanical recanalization with thrombectomy is therefore very attractive; this procedure provides rapid recanalization with no increased risk of hemorrhage from use of thrombolytic agents. Nevertheless, the rheolytic catheter is large and stiff and may not be able to navigate tortuous intracranial vascular anatomy. The authors present their experience with direct dural sinus mechanical thrombectomy performed using the rheolytic catheter via a transcranial route. Two patients with dural sinus thrombosis and rapidly deteriorating levels of consciousness underwent unsuccessful attempts at mechanical thrombolysis via the usual transfemoral route. Through a burr hole over the dural sinus, mechanical thrombectomy was subsequently performed using the thrombectomy catheter. Sinus patency was restored following treatment and both patients demonstrated neurological recovery. Hemorrhage or a rapidly deteriorating neurological condition may preclude the use of systemic or locally delivered thrombolytic agents for the treatment of cerebral venous sinus thrombosis. Mechanical thrombectomy may be the treatment of choice in these circumstances. In patients with limited transfemoral access, a transcranial approach may be used to access the cerebral dural sinuses and thrombectomy may be safely and effectively performed. Further evaluation of this therapy is warranted.

Catheterization↗

A novel endovascular treatment of a wide-necked basilar apex aneurysm by using a Y-configuration, double-stent technique.

Wide-necked bifurcation aneurysms remain a formidable challenge to the neuroendovascular surgeon. A 36-year-old woman with a wide-necked basilar bifurcation aneurysm was unsuccessfully treated by endovascular methods, despite the use of the balloon-remodeling technique. Successful coiling was ultimately achieved by use of a Y-configuration double stent-assisted technique. This novel method of using self-expanding stents may represent a significant advance in the management of basilar apex and other bifurcation aneurysms.

Adult↗

Cardiac pacemakers, ICDs, and loop recorder: evaluation of translational attraction using conventional ("long-bore") and "short-bore" 1.5- and 3.0-Tesla MR systems.

PURPOSE: To evaluate magnet-related translational attraction for cardiac pacemakers, ICDs, and an insertable loop recorder in association with exposure to "long-bore" and "short-bore" 1.5- and 3.0-Tesla MR systems. MATERIALS AND METHODS: Fourteen cardiac pacemakers, four ICDs, and one insertable loop recorder were evaluated for translational attraction using deflection angle tests performed at the points of the highest spatial gradients for long-bore and short-bore 1.5- and 3.0-Tesla MR systems according to ASTM guidelines. RESULTS: Deflection angles ranged from 9-90 degrees for the long-bore and from 11-90 degrees for the short-bore 1.5-T MR system. Deflection angles ranged from 23-90 degrees for the long-bore and from 34-90 degrees for the short-bore 3.0-T MR system. Three of the cardiovascular implants exhibited deflection angles > or = 45 degrees (i.e., indicating that they are potentially unsafe for patients) on the long-bore and short-bore 1.5-T MR systems. Eight implants exhibited deflection angles > or = 45 degrees on the long-bore 3.0-T MR system, while 14 exhibited deflection angles > or = 45 degrees on the short-bore 3.0-T MR system. In general, deflection angles for these cardiovascular implants were significantly (p < 0.01) higher on 1.5- and 3.0-Tesla short-bore compared to the long-bore MR systems. CONCLUSIONS: Several of the cardiovascular implants that underwent evaluation may be problematic for patients undergoing MR procedures using 1.5- and 3.0-T MR systems because of risks associated with magnet-related movements. Obviously, additional MR safety issues must also be considered for these implants.

Cardiovascular Diseases↗

Aneurysm clips: evaluation of magnetic field interactions and translational attraction by use of "long-bore" and "short-bore" 3.0-T MR imaging systems.

BACKGROUND AND PURPOSE: The use of 3.0-T MR systems is increasing worldwide. We evaluated magnetic field interactions and translational attraction for 32 aneurysm clips in association with exposure to "long-bore" and "short-bore" 3.0-T MR imaging systems. METHODS: Thirty-two different aneurysm clips were evaluated in this investigation. Each aneurysm clip was qualitatively evaluated for magnetic field interactions and quantitatively assessed for translational attraction by using the deflection angle test. The deflection angle tests were performed at the points of the highest spatial gradients for long-bore and short-bore 3.0-T MR imaging systems. RESULTS: Seventeen of the 32 aneurysm clips showed positive magnetic field interactions. Deflection angles for the aneurysm clips were significantly (P <.001) higher on the short-bore (range, 0-18 degrees) compared with those recorded on the long-bore (range, 0-16 degrees) 3.0-T MR imaging system. Aneurysm clips made from commercially pure titanium and titanium alloy displayed no translational attraction (n = 15), whereas those made from stainless steel alloy, Phynox, and Elgiloy displayed positive deflection angles (n = 17). CONCLUSION: The 32 different aneurysm clips passed (angle <45 degrees) the deflection angle test by using the long- and short-bore 3.0-T MR imaging systems, indicating that they are safe for patients and other persons in these MR environments (ie, immediate area of MR imaging systems). However, only clips made from the titanium and titanium alloy are entirely safe for patients undergoing MR imaging procedures because of the total lack of magnetic field interactions. The remaining clips require characterization of magnetic field-induced torque. Because of possible differences in the points of the highest spatial gradients for different 3.0-T MR imaging systems, the results are specific to the imaging units and bore designs used in this investigation.

Contraindications↗

Diagnostic imaging for intracerebral hemorrhage.

Magnetic resonance imaging (MRI) is an excellent tool for the diagnosis and evaluation of intracerebral hemorrhage with its unique specificity to hemoglobin degradation products in different stages. Computed tomography (CT) remains the diagnostic test of choice in the setting of acute intracerebral hemorrhage because of its exquisite sensitivity and specificity for small amounts of intracerebral hemorrhage (although there is emerging evidence that MRI may be as sensitive as CT). The effects of the biochemical evolution of intracerebral hemorrhage on the temporal MRI signal changes are described. This article discusses imaging features of the common causes of intracerebral hemorrhage.

Acute Disease↗