PubMed Health⌕ Search

Biomedical subjects

Thomas J Royston

Publications and source records attributed to Thomas J Royston.

10 recordsLinked to original sources

Error propagation model for microscopic magnetic resonance elastography shear-wave images.

Microscopic magnetic resonance elastography is a high-resolution method for visualizing shear waves and assessing the biomechanical viscoelastic properties of small biological samples. In this work, we used error propagation to develop a simple analytical model that relates the signal-to-noise ratio of MR magnitude images to the variance in shear-wave maps collected using gradient-echo and spin-echo phase-contrast pulse sequences. Our model predicts results for shear-wave images in phantoms, which match the experimentally observed phase variance within 8%. This model can be used to optimize MR pulse sequences for elastography studies, as well as other phase-difference techniques in MRI.

Biomechanical Phenomena↗

Interdependence of pulsed ultrasound and shear stress effects on cell morphology and gene expression.

Fluid shear stress is a key biomechanical regulatory factor in a several biological systems including bone tissue. Bone cells are also regulated by exogenous acoustic vibration, which has therapeutic benefits. In this study, we determined the effects of shear stress and pulsed ultrasound (US), alone and in series on osteoblast morphology and gene expression. We observed that shear stress (19 dyne/cm(2)) elongated SaOS-2 cells at 3, 6, 24, and 48 h decreasing their shape index from control values of 0.51 +/- 0.01, 0.60 +/- 0.05, 0.59 +/- 0.04, and 0.45 +/- 0.01 to 0.45 +/- 0.04, 0.47 +/- 0.03, 0.39 +/- 0.02, and 0.33 +/- 0.01, respectively. This morphological effect was inhibited at 24 and 48 h but not at 3 and 6 h by a 20 min pre-exposure to pulsed US (1.5 MHz, 30 mW/cm(2)). Shear stress significantly decreased Bone Morphogenetic Protein-4 (BMP-4) mRNA levels at 1, 2, 3, 6, and 24 h by 32.5 +/- 1.8%, 30.8 +/- 3.5%, 49.6 +/- 2.8%, 23.5 +/- 5.0%, 24.4 +/- 2.3%, respectively. A 20 min pulsed US exposure had no significant effect. However, a 20 min pre-exposure to pulsed US caused significant 39.6 +/- 3.0% and 25.6 +/- 2.7% decreases in BMP-4 levels in shear stress treated cells at 3 and 24 h, respectively. These results show for the first time that pulsed US alters the mechanotransductive effects of shear stress indicating a more comprehensive understanding of therapeutic US will be obtained when it is studied in conjunction with in vivo, regulatory biomechanical forces.

Bone and Bones↗

Microscopic magnetic resonance elastography (microMRE).

Magnetic resonance elastography (MRE) was extended to the microscopic scale to image low-frequency acoustic shear waves (typically less than 1 kHz) in soft gels and soft biological tissues with high spatial resolution (34 micromx34 micromx500 microm). Microscopic MRE (microMRE) was applied to agarose gel phantoms, frog oocytes, and tissue-engineered adipogenic and osteogenic constructs. Analysis of the low-amplitude shear wave pattern in the samples allowed the material stiffness and viscous loss properties (complex shear stiffness) to be identified with high spatial resolution. microMRE experiments were conducted at 11.74 T in a 56-mm vertical bore magnet with a 10 mm diameterx75 mm length cylindrical space available for the elastography imaging system. The acoustic signals were generated at 550-585 Hz using a piezoelectric transducer and high capacitive loading amplifier. Shear wave motion was applied in synchrony with the MR pulse sequence. The field of view (FOV) ranged from 4 to 14 mm for a typical slice thickness of 0.5 mm. Increasing the agarose gel concentration resulted in an increase in shear elasticity and shear viscosity. Shear wave motion propagated through the frog oocyte nucleus, enabling the measurement of its shear stiffness, and in vitro shear wave images displayed contrast between adipogenic and osteogenic tissue-engineered constructs. Further development of microMRE should enable its use in characterizing stiffer materials (e.g., polymers, composites, articular cartilage) and assessing with high resolution the mechanical properties of developing tissues.

Adipose Tissue↗

Microstructural and strength evaluation of regenerate tissue during the consolidation period after vertical mandibular ramus distraction.

Mandibular ramus height restoration by distraction osteogenesis (DO) is a key procedure in mandibular hypoplasia reconstruction. The objective of this study was to evaluate short-term skeletal changes in the regenerated bone after vertical mandibular ramus DO using a buried distraction device. Eight subadult beagle dogs underwent bilateral vertical mandibular ramus DO. After a 7-day latency period, distraction was performed at a rate of 0.5 mm twice a day for 12 days. Four dogs were killed at 1 month and four dogs at 2 months after the end of distraction. One intact beagle was included as an unoperated control. After sacrifice, micro computed tomography (muCT) and mechanical testing of distracted sites were used to measure bone volume (BV), total volume (TV), and mechanical peak load strength, respectively. The muCT images showed wide variation in the response, with some animals demonstrating considerable bone formation and reconstitution of the canal for the inferior alveolar nerve. Quantitatively, BV was no more than 67% and BV/TV was less than 25% of the intact control, and strength was approximately 33% of the intact control value. The 1 and 2 month values were similar. These results suggest that internal distractors can successfully reconstitute bone but that the regenerated tissue did not regain structural and mechanical characteristics of native bone within the 2 month study period.

Animals↗

Syringomyelia hydrodynamics: an in vitro study based on in vivo measurements.

A simplified in vitro model of the spinal canal, based on in vivo magnetic resonance imaging, was used to examine the hydrodynamics of the human spinal cord and subarachnoid space with syringomyelia. In vivo magnetic resonance imaging (MRI) measurements of subarachnoid (SAS) geometry and cerebrospinal fluid velocity were acquired in a patient with syringomyelia and used to aid in the in vitro model design and experiment. The in vitro model contained a fluid-filled coaxial elastic tube to represent a syrinx. A computer controlled pulsatile pump was used to subject the in vitro model to a CSF flow waveform representative of that measured in vivo. Fluid velocity was measured at three axial locations within the in vitro model using the same MRI scanner as the patient study. Pressure and syrinx wall motion measurements were conducted external to the MR scanner using the same model and flow input. Transducers measured unsteady pressure both in the SAS and intra-syrinx at four axial locations in the model A laser Doppler vibrometer recorded the syrinx wall motion at 18 axial locations and three polar positions. Results indicated that the peak-to-peak amplitude of the SAS flow waveform in vivo was approximately tenfold that of the syrinx and in phase (SAS approximately 5.2 +/- 0.6 ml/s, syrinx approximately 0.5 +/- 0.3 ml/s). The in vitro flow waveform approximated the in vivo peak-to-peak magnitude (SAS approximately 4.6 +/- 0.2 ml/s, syrinx approximately 0.4 +/- 0.3 ml/s). Peak-to-peak in vitro pressure variation in both the SAS and syrinx was approximately 6 mm Hg. Syrinx pressure waveform lead the SAS pressure waveform by approximately 40 ms. Syrinx pressure was found to be less than the SAS for approximately 200 ms during the 860-ms flow cycle. Unsteady pulse wave velocity in the syrinx was computed to be a maximum of approximately 25 m/s. LDV measurements indicated that spinal cord wall motion was nonaxisymmetric with a maximum displacement of approximately 140 microm, which is below the resolution limit of MRI. Agreement between in vivo and in vitro MR measurements demonstrates that the hydrodynamics in the fluid filled coaxial elastic tube system are similar to those present in a single patient with syringomyelia. The presented in vitro study of spinal cord wall motion, and complex unsteady pressure and flow environment within the syrinx and SAS, provides insight into the complex biomechanical forces present in syringomyelia.

Adult↗

Acoustic radiation from a fluid-filled, subsurface vascular tube with internal turbulent flow due to a constriction.

The vibration of a thin-walled cylindrical, compliant viscoelastic tube with internal turbulent flow due to an axisymmetric constriction is studied theoretically and experimentally. Vibration of the tube is considered with internal fluid coupling only, and with coupling to internal-flowing fluid and external stagnant fluid or external tissue-like viscoelastic material. The theoretical analysis includes the adaptation of a model for turbulence in the internal fluid and its vibratory excitation of and interaction with the tube wall and surrounding viscoelastic medium. Analytical predictions are compared with experimental measurements conducted on a flow model system using laser Doppler vibrometry to measure tube vibration and the vibration of the surrounding viscoelastic medium. Fluid pressure within the tube was measured with miniature hydrophones. Discrepancies between theory and experiment, as well as the coupled nature of the fluid-structure interaction, are described. This study is relevant to and may lead to further insight into the patency and mechanisms of vascular failure, as well as diagnostic techniques utilizing noninvasive acoustic measurements.

Acoustics↗

Transitional flow at the venous anastomosis of an arteriovenous graft: potential activation of the ERK1/2 mechanotransduction pathway.

We present experimental and computational results that describe the level, distribution, and importance of velocity fluctuations within the venous anastomosis of an arteriovenous graft. The motivation of this work is to understand better the importance of biomechanical forces in the development of intimal hyperplasia within these grafts. Steady-flow in vitro studies (Re = 1060 and 1820) were conducted within a graft model that represents the venous anastomosis to measure velocity by means of laser Doppler anemometry. Numerical simulations with the same geometry and flow conditions were conducted by employing the spectral element technique. As flow enters the vein from the graft, the velocity field exhibits flow separation and coherent structures (weak turbulence) that originate from the separation shear layer. We also report results of a porcine animal study in which the distribution and magnitude of vein-wall vibration on the venous anastomosis were measured at the time of graft construction. Preliminary molecular biology studies indicate elevated activity levels of the extracellular regulatory kinase ERK1/2, a mitogen-activated protein kinase involved in mechanotransduction, at regions of increased vein-wall vibration. These findings suggest a potential relationship between the associated turbulence-induced vein-wall vibration and the development of intimal hyperplasia in arteriovenous grafts. Further research is necessary, however, in order to determine if a correlation exists and to differentiate the vibration effect from that of flow related effects.

Animals↗

Surface response of a viscoelastic medium to subsurface acoustic sources with application to medical diagnosis.

The response at the surface of an isotropic viscoelastic medium to buried fundamental acoustic sources is studied theoretically, computationally and experimentally. Finite and infinitesimal monopole and dipole sources within the low audible frequency range (40-400 Hz) are considered. Analytical and numerical integral solutions that account for compression, shear and surface wave response to the buried sources are formulated and compared with numerical finite element simulations and experimental studies on finite dimension phantom models. It is found that at low audible frequencies, compression and shear wave propagation from point sources can both be significant, with shear wave effects becoming less significant as frequency increases. Additionally, it is shown that simple closed-form analytical approximations based on an infinite medium model agree well with numerically obtained "exact" half-space solutions for the frequency range and material of interest in this study. The focus here is on developing a better understanding of how biological soft tissue affects the transmission of vibro-acoustic energy from biological acoustic sources below the skin surface, whose typical spectral content is in the low audible frequency range. Examples include sound radiated from pulmonary, gastro-intestinal and cardiovascular system functions, such as breath sounds, bowel sounds and vascular bruits, respectively.

Auscultation↗

Passively minimizing structural sound radiation using shunted piezoelectric materials.

Two methods are presented to determine optimal inductance and resistance values of the shunt circuit across a piezoceramic material, which is bonded to a simply supported plate in order to minimize sound radiation from the plate. The first method (DH) makes use of den Hartog's damped vibration absorber principle. The second method (SM) uses the Sherman Morrison matrix inversion theorem. The effectiveness of each method is compared with regard to minimizing total acoustic sound-power radiation and acoustic pressure at a point. Optimization algorithms and case studies are presented using a linearized model for the piezoceramic and using a nonlinear model for the piezoceramic that accounts for the inherent dielectric hysteresis. Case studies demonstrate that the second method (SM) results in superior performance, under both linear and nonlinear system assumptions. Studies also illustrate that, if the nonlinearity in the system is significant, it must be incorporated in the optimization process.

Journal Article↗

The effect of pulsed ultrasound on mandibular distraction.

This study evaluated the effect of pulsed ultrasound on tissue repair and bone growth during mandibular osteodistraction. Twenty-one rabbits were divided into three groups of 7. The distraction started 72 h after surgically severing both sides of the mandible and proceeded at a rate of 1.5 mm/12 h for 5 days. Group I received pulsed ultrasound (nominally 200 micros pulse of 1.5 MHz at a 1.1 kHz pulse repetition frequency, 30 mW/cm2) for 20 min on both sides of the mandible every other day (alternating sides). Group 2 received the same pulsed ultrasound treatment on one side of the mandible every day for 20 min. Group 3 did not receive any ultrasound treatment. Bone formation at the distraction site was assessed by photodensitometry on head radiographs, a vibratory coherence test across the distraction site, a postmortem three-point bending mechanical stiffness test, and a postmortem histological examination. Statistical analyses performed using analysis of variance revealed that pulsed ultrasound enhanced bone formation at the distraction site with a high level of significance when assessed by the increase in new bone photodensity (p = 0.001), vibratory coherence (p = 0.001), mechanical stiffness (p = 0.003), and qualitative histological studies, especially when the pulsed ultrasound treatment was directly applied daily.

Animals↗