Zero filled partial fourier phase contrast MR imaging: in vitro and in vivo assessment.

PURPOSE: To validate partial Fourier phase contrast magnetic resonance (PC MR) with full number of excitation (NEX) PC MR measurements in vitro and in vivo. MATERIALS AND METHODS: MR flow measurements were performed using a partial Fourier and a full NEX PC MR sequence in a flow phantom and in 10 popliteal and renal arteries of 10 different healthy volunteers. Average velocity, peak velocity, and flow results were calculated and compared with regression analysis. RESULTS: Excellent correlations in average velocities (r = 0.99, P < 0.001), peak velocities (r = 0.99, P < 0.001), and flow rates (r = 0.98, P < 0.001) were demonstrated in vitro between the two different acquisitions. For the popliteal arteries there was excellent correlation between peak velocities for both acquisitions (r = 0.98, P < 0.0001); the correlation of average velocity measurements when using all data points in the cardiac cycle for all volunteers was 0.96 (P < 0.001). For the renal arteries the same comparison resulted in a good correlation for average velocity (0.93, P < 0.001) and peak velocity measurements (r = 0.91, P = 0.002), although the correlation coefficient for flow rates was 0.88 (P = 0.004). Blurring of the vessel margins was consistently observed on magnitude images acquired with the partial Fourier method, causing overestimation of the vessel area and some error in the flow measurements. CONCLUSION: Partial Fourier PC MR is able to provide comparable average and peak velocity values when using 1 NEX PC MRI as a reference.

Adult↗

Short breath-hold, volumetric coronary MR angiography employing steady-state free precession in conjunction with parallel imaging.

An ECG-gated, 3D steady-state free precession (SSFP) technique in conjunction with sensitivity encoding (SENSE)-based parallel imaging was implemented for short breath-hold, volumetric coronary MR angiograpy (CMRA). Two parallel imaging acquisition strategies (employing 1 R-R and 2 R-R intervals, respectively) were developed to achieve 1) very short breath-hold times (12 s for a heart rate of 60 bpm), and 2) small acquisition windows to minimize sensitivity to physiologic motion. Both strategies were examined in CMRA applications over a range of heart rates. A four-point scale blinded reading (with 4 indicating the most desirable features) revealed substantial image quality improvements for the accelerated data as compared to the nonaccelerated approach. The 1 R-R interval scheme yielded an image score of 3.39 +/- 0.60, and was found to be particularly suitable for low heart rates (P = 0.0008). The 2 R-R interval strategy yielded an image score of 3.35 +/- 0.64, and was more appropriate for higher heart rates (P = 0.03). The results demonstrate that 3D SSFP combined with parallel imaging is a versatile method for short breath-hold CMRA while maintaining high spatial resolution. This strategy permits imaging of the major coronary artery distributions in two to three breath-holds using targeted slabs, and offers the potential for single breath-hold, large-volume CMRA.

Adult↗

Enhanced viability imaging: improved contrast in myocardial delayed enhancement using dual inversion time subtraction.

In delayed contrast-enhanced MRI for the assessment of myocardial viability, the TI time in a gated inversion-recovery segmented gradient echo sequence is usually selected to null signal from normal myocardium. Although this TI time generates good contrast between the enhancing infarcted tissue and normal myocardium, there is usually less contrast between the infarct and the blood pool. A subtractive technique utilizing two acquisitions at a long and short TI time is proposed to improve the delineation between infarct-blood and infarct-myocardium. The concept was demonstrated in six mongrel dogs with reperfused myocardial infarction. Infarct-normal myocardium contrast (signal difference) using the proposed enhanced viability imaging (ENVI) technique was 142 +/- 50% (P < 0.001) that of standard magnitude inversion recovery (IR), while at the same TI time for the primary image, infarct-blood contrast, was 247 +/- 136% (P < 0.002) that of magnitude IR. Accounting for increased noise due to the subtraction, signal difference-to-noise ratios (SDNR) did not show a significant change for infarct-myocardium but infarct-blood SDNR for ENVI was 174 +/- 105% that of magnitude-IR (P < 0.03). Thus, marked improvement in the delineation of the infarcted zone was noted over a range of TI times.

Animals↗

Feasibility of integrating high-spatial-resolution 3D breath-hold coronary MR angiography with myocardial perfusion and viability examinations.

The study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. All subjects provided informed consent. Three-dimensional breath-hold coronary magnetic resonance (MR) angiography with use of steady-state free precession was performed in 12 patients up to 20 minutes after 0.2 mmol gadolinium-based contrast material per kilogram of body weight was administered. Within 24 heartbeats, a spatial resolution of up to 1.0 x 1.2 x 2.0 mm was achieved. Sixty-five (82%) of the 79 visualized coronary artery segments had a grade of 3 or 4 on a four-point scale of depiction in which grade 4 indicated excellent depiction. Twenty-seven percent (n = 21) of the 79 segments were assigned a grade of 4; 56% (n = 44), a grade of 3; 16% (n = 13), a grade of 2; and 1% (n = 1), a grade of 1. Coronary MR angiography performed as part of a first-pass myocardial perfusion and viability assessment MR imaging examination is feasible and does not involve additional imaging time.

Adult↗

Delayed contrast-enhanced MRI of the aortic wall in Takayasu's arteritis: initial experience.

OBJECTIVE: Delayed contrast-enhanced MRI is increasingly being used for cardiac viability imaging. Takayasu's arteritis is a rare inflammatory disorder of unknown cause that affects the aorta, its major branches, and the pulmonary artery; it is characterized by inflammation and fibrosis in the arterial wall. We report our initial experience with seven patients (six women, one man; age range, 25-62 years) with delayed (20 min) gadolinium-enhanced MRI (inversion recovery prepared gated fast gradient-echo pulse sequence) in patients with known Takayasu's arteritis. CONCLUSION: Patients with Takayasu's arteritis (particularly those with abnormal laboratory values) have evidence of delayed hyper-enhancement on delayed contrast-enhanced MRI. Thus, delayed contrast-enhanced MRI might be a useful technique to identify inflammation in arterial wall.

Adult↗

Fast, three-dimensional free-breathing MR imaging of myocardial infarction: a feasibility study.

Imaging delayed hyperenhancement of myocardial infarction is most commonly performed using an inversion recovery (IR) prepared 2D breathhold segmented k-space gradient echo (FGRE) sequence. Since only one slice is acquired per breathhold in this technique, 12-16 successive breathholds are required for complete anatomical coverage of the heart. This prolongs the overall scan time and may be exhausting for patients. A navigator-echo gated, free-breathing, 3D FGRE sequence is proposed that can be used to acquire a single slab covering the entire heart with high spatial resolution. The use of a new variable sampling in time (VAST) acquisition scheme enables the entire 3D volume to be acquired in 1.5-2 min, minimizing artifacts from bulk motion and diaphragmatic drift and contrast variations due to contrast media washout.

Feasibility Studies↗

Myocardial viability: breath-hold 3D MR imaging of delayed hyperenhancement with variable sampling in time.

A method for visualizing myocardial infarction with a three-dimensional (3D) breath-hold gated acquisition was examined. By using variable sampling in time, whole heart coverage with a single volume acquisition was achieved in 24 heart beats. In a study of 35 patients, in whom 3D volume acquisition was compared with a two-dimensional (2D) acquisition, all regions of myocardial infarction were correctly identified at 3D examination. The mean imaging time for 12 section locations was 8.0 minutes +/- 3.0 with a 2D approach compared with 22 seconds +/- 4 with a 3D approach (P <.001). Advantages were also noted for infarct contrast-to-noise ratio: 60 +/- 37 for 3D versus 33 +/- 20 for 2D imaging (P <.001). No significant differences (P >.05) were noted at qualitative assessment of myocardial suppression, endocardial border visualization, respiratory and cardiac motion artifacts, or confidence of transmurality of the infarct.

Aged↗

Fast method for correcting image misregistration due to organ motion in time-series MRI data.

Time-series MRI data often suffers from image misalignment due to patient movement and respiratory and other physiologic motion during the acquisition process. It is necessary that this misalignment be corrected prior to any automated quantitative analysis. In this article a fast and automated technique for removing in-plane misalignment from time-series MRI data is presented. The method is computationally efficient, robust, and fine-tuned for the clinical setting. The method was implemented and tested on data from 21 human subjects, including myocardial perfusion imaging, renal perfusion imaging, and blood-oxygen level-dependent cardiac T(2*) imaging. In these applications 10-fold or better reduction in image misalignment is reported. The improvement after registration on representative time-intensity curves is shown. Although the method currently corrects translation motion using image center of mass, the mathematical framework of our approach may be extended to correct rotation and other higher-order displacements.

Algorithms↗

MR angiography using steady-state free precession.

Contrast-enhanced MR angiography (CE-MRA) using steady-state free precession (SSFP) pulse sequences is described. Using SSFP, vascular structures can be visualized with high signal-to-noise ratio (SNR) at a substantial (delay) time after the initial arterial pass of contrast media. The peak blood SSFP signal was diminished by <20% 30 min after the initial administration of 0.2 mmol/kg of Gd-chelate. The proposed method allows a second opportunity to study arterial or venous structures with high image SNR and high spatial resolution. A mask subtraction scheme using spin echo SSFP-S(-) acquisition is also described to reduce stationary background signal from the delayed SSFP angiography images.

Adult↗

High-resolution gadolinium-enhanced 3D MRA of the infrapopliteal arteries. Lessons for improving bolus-chase peripheral MRA.

Peripheral magnetic resonance angiography (MRA) is growing in use. However, methods of performing peripheral MRA vary widely and continue to be optimized, especially for improvement in illustration of infrapopliteal arteries. The main purpose of this project was to identify imaging factors that can improve arterial visualization in the lower leg using bolus chase peripheral MRA. Eighteen healthy adults were imaged on a 1.5T MR scanner. The calf was imaged using conventional three-station bolus chase three-dimensional (3D) MRA, two dimensional (2D) time-of-flight (TOF) MRA and single-station Gadolinium (Gd)-enhanced 3D MRA. Observer comparisons of vessel visualization, signal to noise ratios (SNR), contrast to noise ratios (CNR) and spatial resolution comparisons were performed. Arterial SNR and CNR were similar for all three techniques. However, arterial visualization was dramatically improved on dedicated, arterial-phase Gd-enhanced 3D MRA compared with the multi-station bolus chase MRA and 2D TOF MRA. This improvement was related to optimization of Gd-enhanced 3D MRA parameters (fast injection rate of 2 mL/sec, high spatial resolution imaging, the use of dedicated phased array coils, elliptical centric k-space sampling and accurate arterial phase timing for image acquisition). The visualization of the infrapopliteal arteries can be substantially improved in bolus chase peripheral MRA if voxel size, contrast delivery, and central k-space data acquisition for arterial enhancement are optimized. Improvements in peripheral MRA should be directed at these parameters.

Adult↗