PubMed Health⌕ Search

Biomedical subjects

Thomas Lawo

Publications and source records attributed to Thomas Lawo.

11 recordsLinked to original sources

Catheter ablation of regular atrial arrhythmia following surgical treatment of permanent atrial fibrillation.

UNLABELLED: Ablation of Atrial Tachycardia after Antiatrial Fibrillation Surgery. INTRODUCTION: Surgical treatment of atrial fibrillation (AF) is gaining widespread acceptance. However, therapeutic modalities for secondary regular atrial tachycardia are still empiric. METHODS AND RESULTS: After linear atrial cooled-tip radiofrequency ablation (SICTRA) during cardio-surgical procedures to cure permanent AF, patients with regular atrial tachycardia were identified. Invasive electrophysiology including electroanatomic mapping was performed. Catheter ablation was directed to suppress atrial arrhythmia depending on activation mapping findings. Follow-up was performed after 3 months and then after every 6 months. Of 238 patients, 12 (5.0%) were identified with regular secondary arrhythmias (12 +/- 7 months after surgery) including 9 (3.8%) with persistent forms originating from the right atrium (RA) in six (66%) (isthmus-dependent macroreentry in 4, incisional macroreentry in 1, and RA ectopy in 1). All patients with RA origin of the tachycardia were successfully ablated. Two patients had left atrial (LA)-macroreentry circling around the mitral valve indicating insufficiency of the intraoperative ablation procedure: one patient was successfully ablated within the LA isthmus, in the other patient no complete conduction block could be induced. One patient had LA-macroreentry degenerating into AF, and ablation was not performed. During follow-up (9 +/- 4 months), no recurrences of atrial tachycardias were documented after successful ablation. CONCLUSIONS: Persistent regular "secondary" arrhythmia occurred in 3.8% (9/238) of patients after SICTRA to treat permanent AF. Predominantly (67%; 6/9), the arrhythmia was located in the RA mostly incorporating the RA-isthmus. Catheter ablation was highly effective for RA tachycardia (100%). In three cases (33%), LA-macroreentry was documented and catheter ablation was successful in only one patient (overall success 78%).

Atrial Fibrillation↗

Electrical signals applied during the absolute refractory period: an investigational treatment for advanced heart failure in patients with normal QRS duration.

Cardiac resynchronization therapy has been shown to be an effective treatment for patients with systolic ventricular dysfunction, prolonged (>120 ms) QRS duration, and New York Heart Association (NYHA) functional class III or IV symptoms despite optimal medical therapy. However, studies show that a majority of heart failure patients have QRS duration <120 ms. We have been investigating the potential utility of cardiac contractility modulating (CCM) signals as a treatment option for such patients. Cardiac contractility modulating signals are non-excitatory signals applied during the absolute refractory period using a pacemaker-like device that connects to the heart with pacemaker leads. Acute studies carried out in animals and humans with heart failure suggest that CCM signals can enhance the strength of left ventricular contraction. Results of initial long-term studies designed mainly to demonstrate feasibility and provide preliminary indication of safety in patients with medically refractory NYHA functional class III heart failure are summarized. The results of these preclinical and clinical studies formed the basis for proceeding with two prospective, randomized clinical studies currently underway to definitively test the safety and efficacy of this treatment.

Animals↗

Monitoring of physical activity and heart rate variability in patients with chronic heart failure using cardiac resynchronization devices.

Cardiac resynchronization therapy (CRT) devices not only deliver effective treatment but may also serve as valuable diagnostic tools in heart failure management. In the present study, the minutes of daily physical activity and heart rate variability, measured by sensors incorporated into such a device, reflected the effects of CRT and were related to New York Heart Association functional class.

Aged↗

Human histopathology of electroanatomic mapping after cooled-tip radiofrequency ablation to treat ventricular tachycardia in remote myocardial infarction.

INTRODUCTION: Catheter ablation of ventricular tachycardia (VT) in remote myocardial infarction (MI) often requires excessive mapping procedures. Documentation of the electrical substrate via electrogram amplitude may help to identify regions of altered myocardium resembling exit areas of reentrant VTs. METHODS AND RESULTS: A patient with multiple symptomatic monomorphic VTs (biventricular ICD, remote MI) underwent electroanatomic substrate mapping (CARTOtrade mark) for VT ablation. Regions of scar (bipolar electrogram amplitudes or=1.5 mV), and "altered" myocardium (0.5-1.5 mV) were identified. Ablation was directed to regions with "altered" myocardium based on pace map correlation. After ablation the clinical VT did not reoccur. The patient died due to worsening of heart failure 7 days afterward. During postmortal evaluation specified sites of electroanatomic mapping were correlated to histopathological findings. Annotated scar areas were documented to consist of areas with massive fibrosis (>or=80% of mural composition). Ablations were found to span through regions with intermediate fibrosis (21-79%) mapped as "altered" myocardium. Ablation produced transmural coagulation necrosis of mesh-like fibrotic tissue with interspersed remnants of myocardial cells up to a maximum depth of 7.0 mm. Subendocardial intramural bleedings were universal findings 7 days after ablation. CONCLUSIONS: Electroanatomic substrate mapping for VT ablation sufficiently identified regions of scar and normal myocardium. Regions with bipolar electrogram amplitudes between 0.5 and 1.5 mV were found to correlate to areas of "intermediate" fibrosis (21-79%) with only remnant strands of myocardial cells and were identified as target region for ablation. Cooled-tip endocardial radiofrequency ablation lead to transmural coagulation necrosis up to a depth of 7.0 mm.

Aged↗

[Health care quality: medication and prevention in patients with and without coronary heart disease].

BACKGROUND AND PURPOSE: Next to noninvasive-recently also invasive-diagnostics, ambulant care in patients with coronary heart disease (CHD) should focus on optimal medication and prevention. The aim of this study was to evaluate actual health care quality concerning drug prescription and preventive care in patients with CHD. PATIENTS AND METHODS: This prospective study was conducted from March 1999 to February 2002 at the University Hospital Bergmannsheil, Bochum, Germany. 300 patients admitted with a suspected CHD and without previous coronary angiography or myocardial infarction were enrolled. Diagnostic and therapeutic regimen complied with actual guidelines. 248 patients (82.7%) including 116 patients with angiographically confirmed CHD were examined after 1 year. RESULTS: On follow-up, only 70.9% of patients with confirmed CHD received a beta-blocker, 83.6% were treated with platelet aggregation inhibitors. Body mass index, portion of overweight patients, and HbA(1c) in patients with diabetes did not change during observation. After 1 year, 48.0% of the subjects had a systolic blood pressure > 139 mmHg, in 22.6% diastolic pressure level was > 89 mmHg. Blood level of low-density cholesterol exceeded the recommended range in 57.0% of the cases observed with equally high portion of inadequately treated patients in the group with confirmed CHD and in the group without CHD. CONCLUSION: Drug therapy, primary and secondary prevention in the observed subjects were fairly poor. Remarkable deficits in health care quality became obvious. There is no lack in availability of evaluated, effective and efficient measures. Thus, physicians' efforts to implement evidence-based guidelines into clinical practice have to be strengthened.

Adrenergic beta-Antagonists↗

Mortality of patients with implanted cardioverter/defibrillators in relation to episodes of atrial fibrillation.

AIMS: This study was undertaken to evaluate if a history of episodes of atrial fibrillation (AF) has an effect on survival in patients (pts) with implanted cardioverter defibrillators (ICD). METHODS AND RESULTS: Retrospective analysis of baseline characteristics, medication and endpoints in pts receiving a dual-chamber ICD comparing pts without (group 1: n = 291) and with a history of AF (group 2: n = 68). Pts in groups 1 and 2 did not differ with regard to baseline characteristics. Forty-one pts (8.7%) experienced a detected episode of AF. During the study period (mean follow-up 9.5 months) 25 pts died (5.8% of group 1 vs 11.8% of group 2). Patient survival was found to be 97.9% vs 91.2% ( n = 279 vs 63) at 3 months after implantation, 97.5% vs 89.7% ( n = 244 vs 54) at 6 months, and 93.7% vs 86.5% ( n = 96 vs 28) at 12 months in group 1 vs group 2 (p = 0.005). The risk of death increased after a first episode of AF was experienced during follow-up (RR = 5.0, p = 0.0007). Independent predictors of mortality are NYHA class (p = 0.002, history of AF (p = 0.009 for predicting early mortality), and detected episodes of AF during follow-up (p = 0.001). CONCLUSION: ICD-patients with a history of AF had a higher than average risk of death early after implantation and after device-detected episodes of AF.

Anti-Arrhythmia Agents↗

Form analysis using digital signal processing reliably discriminates far-field R waves from P waves.

The correct detection of atrial arrhythmias by pacemakers is often limited by the presence of far-field R waves (FFRWs) in the atrial electrogram. Digital signal processing (DSP) of intracardiac signals is assumed to provide improved discrimination between P waves and FFRWs when compared to current methods. For this purpose, 100 bipolar and unipolar intracardiac atrial recordings from 31 patients were collected during pacemaker replacement and used for the off-line application of a novel DSP algorithm. Digital processing of the atrial intracardiac electrogram (IEGM) signals (8 bit, 800 samples/s) included filtering and calculation of the maximum amplitude and slope of the detected events. The form parameter was calculated, being the sum of the most negative value of the amplitude and that of the slope of the detected event. The algorithm collects form parameter data of P waves and FFRWs and composes histograms of these data. A sufficiently large gap between the FFRW and P wave histograms allows discrimination of these two signals based on form parameters. Three independent observers reviewed the reliability of classification with this algorithm. Sensitivity and specificity of FFRW detection were 99.63% and 100%, respectively, and no P waves were falsely classified. It can be concluded that this novel DSP algorithm shows excellent discrimination of FFRWs under off-line conditions and justify the implementation of this algorithm in future pacemakers for real-time discrimination between P waves and FFRWs. This method prevents false mode switching and allows correct and immediate intervention pacing for atrial tachyarrhythmias.

Algorithms↗

Prehospital therapy with the platelet glycoprotein IIb/IIIa inhibitor eptifibatide in patients with suspected acute coronary syndromes: the Bochum feasibility study.

STUDY OBJECTIVES: To assess the practical application and safety of prehospital antithrombotic therapy with the glycoprotein (GP) IIb/IIIa inhibitor eptifibatide for patients with suspected acute coronary syndrome (ACS) or myocardial infarction (MI). DESIGN: Open-labeled pilot study. Patients with typical chest pain who were seen within 6 h of the onset of symptoms were enrolled in the mobile emergency ambulance. Patients were stratified by even/uneven days to receive standard treatment or standard treatment plus an IV bolus of eptifibatide (180 microg/kg body weight) followed by a continuous eptifibatide infusion (2 microg/kg/min). The main outcome measurement was a combination of prehospital or in-hospital death, reinfarction, revascularization of target vessels, and major bleeding complications. RESULTS: A total of 356 patients (age range, 29 to 75 years; women, 24.7%) were included in the analysis. On admission to the hospital, the diagnosis of ACS or MI was confirmed in approximately 60% of patients, and alternative diagnoses were made in 40% of patients. The rates of complications, including fatal and nonfatal complications occurring during transportation and during subsequent hospitalization, were similar in both study groups. The primary end point occurred in 11.8% of patients in the control group, and in 9.6% of those in the eptifibatide group (difference not significant). CONCLUSION: The prehospital administration of the GP IIb/IIIa inhibitor eptifibatide is feasible and safe in patients with clinically suspected ACS and MI. The benefit of this treatment has yet to be established in a large-scale multicenter study.

Aged↗

Clinical and angiographic results of coronary artery stenting using PURA-VARIO (PUVA) stents.

BACKGROUND: Many different stent types are available for intracoronary placement. No clinical trial has demonstrated clearly the superiority of any stent design over another. METHODS: This study was designed to analyze clinical and angiographic results after using intracoronary PURA-VARIO (Devon Medical, Hamburg, Germany) (PUVA) stents. A total of 306 implanted stents were investigated in a series of 217 unselected patients (61.2 +/- 10.7 years, 74.3% male). Stenting was performed electively and during acute coronary syndromes. Stents were manually mounted on angioplasty balloons and expanded in the target lesion. Angiographic measurements were carried out by quantitative coronary angiography. RESULTS: Stenting was successful in 214/217 patients (98.8%). During hospitalization (median three days) 206 patients (94.9%) were free from adverse cardiac events. Stent thrombosis occurred in five patients (2.3%), Q-wave infarction in one (0.5%) and urgent percutaneous target vessel revascularization in four (1.8%). Follow-up angiography, performed in 170 patients (78.3%) showed a restenosis (>/=50% diameter stenosis) in 44/170 patients (25.9%), requiring angioplasty in 29 (17.2%). A surgical revascularization was recommended in 13 patients (7.6%). One patient died during follow-up from an unknown cause; however, sudden cardiac death was most likely. CONCLUSIONS: PUVA stents are characterized by a high level of safety and efficacy. Clinical and angiographic results are comparable with those of other approved stents.

Aged↗

Left atrial versus bi-atrial Maze operation using intraoperatively cooled-tip radiofrequency ablation in patients undergoing open-heart surgery: safety and efficacy.

OBJECTIVES: We sought to determine whether limited left atrial Maze surgery encircling each of the pulmonary veins, using cooled-tip radiofrequency (RF) ablation, is as effective as the bi-atrial approach? BACKGROUND: The original Cox/Maze operation effectively restores sinus rhythm (SR) in patients with atrial fibrillation (AF). Ablation procedures aimed at eliminating pulmonary vein foci have produced promising short-term success. METHODS: This was a prospective analysis of patients with chronic AF undergoing open-heart surgery in addition to the Maze operation, using intraoperatively cooled-tip RF ablation either in the left atrium alone (group A) or in both atria (group B). RESULTS: Patients in group A (n = 21) and group B (n = 49) did not differ in terms of their baseline characteristics. Concomitant open-heart surgical procedures included mitral valve replacement (3 vs. 25), mitral valve plasty (0 vs. 2), mitral and aortic valve replacement (1 vs. 1), aortic valve replacement (4 vs. 6) and coronary artery bypass grafting (13 vs. 15) in groups A and B, respectively. Follow-up ranged from 1 to 50 months. The overall cumulative rates of SR were 82% in group A and 75% in group B, without a statistically significant difference (p = 0.571). Bi-atrial contraction was revealed in 92.3% of patients in SR in group A and in 79.2% in group B. The cumulative survival rates were 90.5% in group A and 77.9% in group B (p = 0.880). CONCLUSIONS: A left or bi-atrial Maze operation using intraoperatively cooled-tip RF ablation can safely be combined with open-heart surgery. A left atrial Maze procedure seems to be as effective as the bi-atrial procedure and restores SR in 82% of patients.

Aged↗

Acute and long-term clinical significance of myocardial contusion following blunt thoracic trauma: results of a prospective study.

BACKGROUND: The clinical significance of myocardial contusion (MC) following blunt thoracic trauma is still unknown. Accordingly, in this prospective study in a regional trauma center we investigated the acute and long-term clinical significance of MC. METHODS: One-hundred eighteen patients with manifest or suspected blunt thoracic trauma were evaluated for cardiac injury. Initial assessment was based on results of electrocardiographic, echocardiographic, and serial enzyme measurements. A follow-up (FU) assessment conducted at 3 and 12 months, respectively, was performed using electrocardiography, echocardiography, and a bicycle ergometry exercise test. RESULTS: Of the 118 patients in the total sample, 67 (56.8%) required admission to the surgical intensive care unit (SICU) because of the severity of their noncardiac injuries. Fourteen patients of the total sample (11.8%) were diagnosed with MC and 13 of these (92.9%) belonged to the intensive care admissions, thus representing an incidence of 19.4% in this patient group. During the hospitalization period none of the patients with MC experienced acute cardiac complications. Eighty-six patients (72.0%) were assessed at FU. No new pathologies were found except in one patient. Exercise testing revealed no ECG abnormalities and none of the patients experienced limitations on the bicycle ergometer due to a cardiac cause. CONCLUSIONS: The incidence of 19.7% of MC in our patients with blunt chest injury requiring intensive care treatment indicates that this condition is frequent in polytraumatized patients. Outcome and prognosis in patients with MC is favorable and, thus, routine cardiac work-up is not indicated. Specific diagnostic and therapeutic measures should be limited to cases where cardiac complications develop.

Adult↗