PubMed Health⌕ Search

Biomedical subjects

Thomas M Holsen

Publications and source records attributed to Thomas M Holsen.

9 recordsLinked to original sources

PCB mass transfer coefficients determined by application of a water surface sampler.

A water surface sampler (WSS) was employed in combination with greased surface deposition plates (GSDPs) to measure the particulate dry deposition and gas exchange of polychlorinated biphenyls (PCBs) in Chicago, IL. Vapor phase PCB fluxes were calculated by subtracting the particulate fluxes obtained from GSDPs from total (particulate+gas) fluxes obtained from the WSS. Vapor phase PCB fluxes were divided by ambient air concentrations measured with a high volume sampler to calculate overall gas phase PCB mass transfer coefficients (K(G)). The calculated average PCB MTC was 0.54+/-0.47 cm s(-1). This experimentally determined average gas phase overall mass transfer coefficient, K(G), agreed well with the ones reported from studies using similar techniques and agreed well with modeled values obtained using MTC correlations developed for the WSS.

Air Pollutants↗

Computational fluid dynamic modeling of two passive samplers.

To effectively use a passive sampler for monitoring trace contaminants in the gas-phase, its sampling characteristics as a function of ambient wind conditions must be known. In this study two commonly used passive samplers were evaluated using computational fluid dynamics. Contaminant uptake by the polyurethane foam (PUF) was modeled using a species transport model. The external-internal flow interactions in the sampler were characterized, and the uptake rates of contaminant species were quantified. The simulations show that flow fields in the samplers have strong velocity gradients, and single-point velocity measurements do not capture flow interactions accurately. Sampling rates calculated for a PUF in freestream are in good agreement with sampling rates for PUFs in the passive samplers studied for the same average velocity over the PUF. The calculated sampling rates are in general agreement with those obtained experimentally by other researchers.

Air Pollutants↗

Mass balance assessment for mercury in Lake Champlain.

A mass balance model for mercury in Lake Champlain was developed in an effort to understand the sources, inventories, concentrations, and effects of mercury (Hg) contamination in the lake ecosystem. To construct the mass balance model, air, water, and sediment were sampled as a part of this project and other research/monitoring projects in the Lake Champlain Basin. This project produced a STELLA-based computer model and quantitative apportionments of the principal input and output pathways of Hg for each of 13 segments in the lake. The model Hg concentrations in the lake were consistent with measured concentrations. Specifically, the modeling identified surface water inflows as the largest direct contributor of Hg into the lake. Direct wet deposition to the lake was the second largest source of Hg followed by direct dry deposition. Volatilization and sedimentation losses were identified as the two major removal mechanisms. This study significantly improves previous estimates of the relative importance of Hg input pathways and of wet and dry deposition fluxes of Hg into Lake Champlain. It also provides new estimates of volatilization fluxes across different lake segments and sedimentation loss in the lake.

Ecosystem↗

Gas-phase deposition of polychlorinated biphenyls (PCBs) to a water surface sampler.

In this study a water surface sampler (WSS) was utilized to directly measure gas phase deposition of polychlorinated biphenyls (PCBs). The measured gas phase PCB fluxes averaged about 880 +/- 660 ngm(-2)d(-1), which was higher than the fluxes calculated using simultaneously measured air and water concentrations for natural surface waters. These large fluxes were due to fact that the measured fluxes were only in the absorption direction since deposited PCBs were continuously removed from the system using an XAD column resulting in the maximum possible flux rate from the air to the WSS water. Ambient air PCBs were also sampled simultaneously with a modified high volume sampler. The gas phase PCB concentrations changed between 0.90 and 4.46 ngm(-3) (2.18 +/- 1.16 ngm(-3)). The mass transfer coefficients (MTCs), calculated by dividing the fluxes by the gas phase concentrations was 0.40 +/- 0.36 cms(-1). The average MTC was comparable with those calculated using a similar configuration of a WSS.

Air Movements↗

Comparison between back-trajectory based modeling and Lagrangian backward dispersion modeling for locating sources of reactive gaseous mercury.

Reactive gaseous mercury (RGM) was measured using an annular denuder coated with potassium chloride at three rural sites (Potsdam, Stockton, and Sterling) in New York State from April 2002 to April 2003. Concentrations of RGM ranged from 0.1 to 84.6 pg m(-3) with large spatial and temporal variation. Potential source contribution function (PSCF), a common receptor modeling tool, was used with these measurements, and source-receptor relationships were calculated using back-dispersion and deposition as well as back-trajectories. Modeling results were compared with the RGM emissions inventory, and Spearman rank-order correlation coefficients were calculated. PSCF results incorporating backward dispersion and deposition were better correlated with the emissions inventory than PSCF based on back-trajectories alone. This difference was determined to be mainly due to the inclusion of dispersion rather than deposition. The main sources of RGM were suggested to be coal-fired power plants in New York and Pennsylvania, the large copper smelter in Quebec, and the taconite mining areas around the Great Lakes.

Air Movements↗

Concentrations and gas/particle partitioning of PCBs in Chicago.

Thirty seven air samples were collected in Chicago, IL from June to October 1995 and analyzed for gas and particle concentrations of polychlorinated biphenyls (PCBs). Lower molecular weight (MW) PCBs dominated the samples and on average 95% of the Sigma50PCB concentration (gas+particulate) was in the vapor phase. Sigma50PCB concentrations were classified based on prevailing winds (lake and land). The Sigma50PCB concentration varied between 0.42 and 5.21 ng/m3 (1.80+/-1.70 ng/m3) for lake and 0.53 and 8.31 ng/m3 (2.41+/-2.15 ng/m3) for land wind directions. Back trajectory analyses suggested that SW of Chicago can be an important local or regional source sector for PCBs. Partitioning between gas and particulate phases was modeled using the Junge-Pankow model. The measured particle phase concentrations for low MW PCBs were lower than those predicted by the model while the opposite was observed for high MW PCBs. Plots of gas/particle partition coefficient (log Kp) vs. subcooled liquid vapor pressure (log pL(0)) had reasonable correlations for individual samples but the slope varied among the samples. Samples that originated from over the lake had higher slopes than samples that originated from over the land.

Air Pollutants↗

Comparing Nafion and ceramic separators used in electrochemical purification of spent chromium plating solutions: cationic impurity removal and transport.

This study focuses on the electrolytic regeneration of spent chromium plating solutions. These solutions contain a significant amount of chromium and a lesser amount of other heavy metals, which makes them a significant environmental concern and an obvious target for recycling and reuse. The type of separator used is extremely critical to the performance of the process because they are the major resistance in the transport-related impurity (Cu(II), Ni(II), and Fe(III)) removals from contaminated chromic acid solutions. A Nafion 117 membrane and a ceramic diaphragm separator traditionally used in the industry were tested for comparison. It was found that the mobilities of Cu(II) and Ni(II) were similar and higher than that of Fe(III) using both separators. The mobility of each cation was smaller in the Nafion membrane than in the ceramic diaphragm. The measured conductivity of the ceramic diaphragm was slightly higher than that of Nafion membrane. However, the Nafion membrane was much thinner than the ceramic diaphragm resulting in the system using the Nafion membrane having higher impurity removal rates than the system using the ceramic diaphragm. The removal rates were approximately equal for Cu(II) and Ni(II) and lowest for Fe(III). Both current and initial concentration affected the removal rates of the impurities. Modeling results indicated that a system using a Nafion separator and a small catholyte/anolyte volume ratio was better than a system using a ceramic separator for removing impurities from concentrated plating solutions if the impurities transported into the catholyte are deposited or precipitated.

Ceramics↗

Locating and quantifying PCB sources in Chicago: receptor modeling and field sampling.

Potential source contribution function (PSCF) modeling using polychlorinated biphenyl (PCB) concentrations measured in the Chicago area resolved three PCB source sectors. They were (i) the direction northwest of Chicago, (ii) the direction southwest of Chicago, and (iii) the south side of Chicago in the neighborhood of Lake Calumet. The area south of Chicago was further examined by taking upwind/ downwind samples near a landfill and sludge drying beds. Results identified the sludge drying beds and a large landfill as PCB sources to the atmosphere. Another PCB source identified in Chicago was a transformer storage yard. This site had the highest upwind/downwind concentration increments in this study (downwind PCB concentrations were more than 5 times those in the upwind air). These PCB sources were characterized in terms of inventories, emission rates, contributions, and PCB congener profiles (fingerprints). Preliminarily results indicate that the sludge may emit up to 90 kg/yr of PCBs to the air. This amount is probably not a significant contribution of PCBs to the Chicago atmosphere on the basis of dispersion modeling results and a simple box model.

Chicago↗

Measured summertime concentrations of particulate components, Hg0, and speciated polycyclic aromatic hydrocarbons at rural sites in New York State.

Daily PM2.5 samples, Hg0 and speciated polycyclic aromatic hydrocarbon (PAH) were simultaneously collected at Potsdam and Stockton site in NY during the summers of 2000 and 2001. Samples for determination of the mass concentration and chemical composition of the PM2.5 were obtained with a speciation network PM2.5 sampler. Chemical composition including trace elemental composition, water-soluble ions, and elemental carbon were analyzed. Elemental mercury and PAHs were sampled separately. Daily PM2.5 concentrations ranged from 0.47 to 53.7 microg m(-3) at the Potsdam site, and from 0.82 to 47.23 microg m(-3) at the Stockton site with large daily differences between the two sites. Potsdam consistently had lower mass values than Stockton. The greatest contributors to the PM2.5 mass (generally >0.1 microg/m(3)) were sulfate, nitrate, ammonium, and BC at both sites. Seventeen PAHs were identified at each site in 2000 and the average total concentrations were 3.2 ng/m(3) and 2.9 ng/m(3) at the Potsdam and Stockton sites, respectively. The mean vapor phase mercury concentration at the Potsdam site (2.4 +/-1.2 ng m(-3), n=93) was higher than that at the Stockton site (1.2 +/- 1.0 ng m(-3), n=60) in 2000, whereas in 2001, the average concentrations were 1.1 ng m(-3) and 1.6 ng m(-3) at the Potsdam and Stockton sites, respectively. In general, vapor phase mercury concentrations increased with increasing ambient temperature at the Stockton site in 2000. These differences in values between 2000 and 2001 can be largely explained by distinct differences in the meteorological regimes that dominated in the different years.

Aerosols↗